文献速递心血管MR

健康心脏联盟提供的心血管磁共振参考范围

Cardiovascular Magnetic Resonance Reference Ranges From the Healthy Hearts Consortium.
PubMed 文献 · JACC Cardiovasc Imaging · 2024-04-10

健康心脏联盟汇总9,088例经核实健康个体的心血管磁共振研究,按年龄、性别和种族分层建立心房和心室指标的参考范围(95%预测区间),并分析分割方法、扫描仪厂商和磁场强度的影响。

要点

  • 参考范围以95%预测区间报告,按年龄、性别和种族分层。
  • 涵盖18-83岁成人,使用cvi42软件及三种分割方法(平滑、乳头肌、解剖)勾画。
  • 样本以白人为主(81.7%),1.5-T扫描占96.6%,西门子设备占91.3%。

核心结论

  • 健康心脏联盟提供了可用于临床实施的健康人心血管磁共振体积参考范围资源。

研究设计与样本

  • 国际协作研究,纳入9,088例经核实健康个体的心血管磁共振研究,使用cvi42 5.14原型版软件由2名专家阅片者分析,采用三种分割方法(平滑、乳头肌、解剖)勾画心室和心房内膜及外膜边界。

诊断标准与关键数值

  • 参考范围以95%预测区间报告,按年龄、性别和种族分层,涵盖心房和心室指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The absence of population-stratified cardiovascular magnetic resonance (CMR) reference ranges from large cohorts is a major shortcoming for clinical care.

OBJECTIVES: This paper provides age-, sex-, and ethnicity-specific CMR reference ranges for atrial and ventricular metrics from the Healthy Hearts Consortium, an international collaborative comprising 9,088 CMR studies from verified healthy individuals, covering the complete adult age spectrum across both sexes, and with the highest ethnic diversity reported to date.

METHODS: CMR studies were analyzed using certified software with batch processing capability (cvi42, version 5.14 prototype, Circle Cardiovascular Imaging) by 2 expert readers. Three segmentation methods (smooth, papillary, anatomic) were used to contour the endocardial and epicardial borders of the ventricles and atria from long- and short-axis cine series. Clinically established ventricular and atrial metrics were extracted and stratified by age, sex, and ethnicity. Variations by segmentation method, scanner vendor, and magnet strength were examined. Reference ranges are reported as 95% prediction intervals.

RESULTS: The sample included 4,452 (49.0%) men and 4,636 (51.0%) women with average age of 61.1 ± 12.9 years (range: 18-83 years). Among these, 7,424 (81.7%) were from White, 510 (5.6%) South Asian, 478 (5.3%) mixed/other, 341 (3.7%) Black, and 335 (3.7%) Chinese ethnicities. Images were acquired using 1.5-T (n = 8,779; 96.6%) and 3.0-T (n = 309; 3.4%) scanners from Siemens (n = 8,299; 91.3%), Philips (n = 498; 5.5%), and GE (n = 291, 3.2%).

CONCLUSIONS: This work represents a resource with healthy CMR-derived volumetric reference ranges ready for clinical implementation.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Raisi-Estabragh Z, Szabo L, McCracken C, et al. Cardiovascular Magnetic Resonance Reference Ranges From the Healthy Hearts Consortium. JACC Cardiovasc Imaging. 2024. PMID: 38613554. doi:10.1016/j.jcmg.2024.01.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。