基于AI自动股骨胫骨长度测量在儿童患者狭缝扫描X线片上的下肢生长评估
本回顾性研究训练AI模型在儿童站立位狭缝扫描X线片上分割股骨和胫骨并测量下肢长度,用AI测量值构建生长曲线并与Anderson-Green方法比较。AI模型测量股骨、胫骨和下肢的平均绝对误差分别为0.25、0.27和0.33 cm;在外部测试集上AI生长曲线的90%覆盖概率为86.7%,高于Anderson-Green方法的73.4%(P < .001)。
要点
- AI模型在儿童狭缝扫描X线片上自动测量股骨、胫骨和下肢长度,测试集平均绝对误差分别为0.25、0.27和0.33 cm。
- 基于AI测量构建的生长曲线在外部测试集上90%覆盖概率为86.7%,高于Anderson-Green方法的73.4%。
- AI生长曲线较传统Anderson-Green方法能更准确反映儿童下肢生长。
核心结论
- 基于多样儿童数据集站立位狭缝扫描X线片AI测量构建的下肢生长曲线,能更准确预测儿童生长。
研究设计与样本
- 回顾性研究,纳入2015年8月至2022年2月期间接受至少两次狭缝扫描X线检查的0-21岁儿童患者523例共1874次检查(平均年龄12.7岁±2.8岁,349例女性)。训练Mask Region-based Convolutional Neural Network在X线片上分割股骨和胫骨并测量总腿长、股骨长和胫骨长,以平均绝对误差评估准确性;训练集、验证集和内测试集分别包括114、25和64次检查;全部1874次检查用于生成生长曲线;外部测试集154次检查用于比较。
诊断标准与关键数值
- AI测量测试集平均绝对误差:股骨0.25 cm、胫骨0.27 cm、下肢0.33 cm;外部测试集90%覆盖概率:AI模型86.7%(95% CI: 82.9, 90.5)vs Anderson-Green方法73.4%(95% CI: 68.4, 78.3),χ2检验P < .001。
临床应用与阅片要点
- AI自动测量可在儿童站立位狭缝扫描X线片上测量股骨、胫骨和下肢长度并用于生长评估,其生长曲线较Anderson-Green方法覆盖概率更高(86.7% vs 73.4%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Commonly used pediatric lower extremity growth standards are based on small, dated data sets. Artificial intelligence (AI) enables creation of updated growth standards. Purpose To train an AI model using standing slot-scanning radiographs in a racially diverse data set of pediatric patients to measure lower extremity length and to compare expected growth curves derived using AI measurements to those of the conventional Anderson-Green method. Materials and Methods This retrospective study included pediatric patients aged 0-21 years who underwent at least two slot-scanning radiographs in routine clinical care between August 2015 and February 2022. A Mask Region-based Convolutional Neural Network was trained to segment the femur and tibia on radiographs and measure total leg, femoral, and tibial length; accuracy was assessed with mean absolute error. AI measurements were used to create quantile polynomial regression femoral and tibial growth curves, which were compared with the growth curves of the Anderson-Green method for coverage based on the central 90% of the estimated growth distribution. Results In total, 1874 examinations in 523 patients (mean age, 12.7 years ± 2.8 [SD]; 349 female patients) were included; 40% of patients self-identified as White and not Hispanic or Latino, and the remaining 60% self-identified as belonging to a different racial or ethnic group. The AI measurement training, validation, and internal test sets included 114, 25, and 64 examinations, respectively. The mean absolute errors of AI measurements of the femur, tibia, and lower extremity in the test data set were 0.25, 0.27, and 0.33 cm, respectively. All 1874 examinations were used to generate growth curves. AI growth curves more accurately represented lower extremity growth in an external test set (n = 154 examinations) than the Anderson-Green method (90% coverage probability: 86.7% [95% CI: 82.9, 90.5] for AI model vs 73.4% [95% CI: 68.4, 78.3] for Anderson-Green method; χ2 test, P < .001). Conclusion Lower extremity growth curves derived from AI measurements on standing slot-scanning radiographs from a diverse pediatric data set enabled more accurate prediction of pediatric growth. © RSNA, 2024 Supplemental material is available for this article.
引用
- Zech JR, Santos L, Staffa S, et al. Lower Extremity Growth according to AI Automated Femorotibial Length Measurement on Slot-Scanning Radiographs in Pediatric Patients. Radiology. 2024. PMID: 38687217. doi:10.1148/radiol.231055
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。