文献速递神经外周血管MRDSA

评估非增强磁共振血管成像序列在直接型颈动脉海绵窦瘘术前综合分析中的诊断效能

Evaluating the diagnostic performance of non-contrast magnetic resonance angiography sequences in the pre-procedural comprehensive analysis of direct carotid cavernous fistula.
PubMed 文献 · Neuroradiology · 2024-04-06

本研究为单中心研究,纳入15例连续直接型颈动脉海绵窦瘘患者,以DSA为金标准,比较TOF与silent MRA在术前评估瘘口位置、大小、引流静脉及侧支沟通动脉的效能。TOF MRA对瘘口位置识别敏感度更高(76.9% vs 69.2%),定位准确率93.3% vs 73.3%;silent MRA对受累静脉显示的敏感度(90% vs 76%)和准确率(87.69 vs 94.36)更高。作者认为联合两种序列可评估DCCF的多种血管构筑特征,有助于治疗规划。

要点

  • TOF MRA对DCCF瘘口定位的敏感度76.9%、准确率93.3%,均高于silent MRA的69.2%和73.3%。
  • silent MRA对受累静脉显示的敏感度90%、准确率87.69,高于TOF MRA的76%和94.36。
  • 作者认为联合TOF与silent MRA可评估DCCF多种血管构筑特征,有助于治疗规划。

核心结论

  • TOF MRA对DCCF的动脉特征(瘘口位置和大小)评估更优;两种MRA均可识别静脉特征,但silent MRA与DSA相关性更好,不受瘘口大小和邻近程度影响;联合两种序列可评估DCCF多种血管构筑特征,有助于治疗规划。

研究设计与样本

  • 单中心研究,纳入15例连续DCCF患者,所有患者均接受TOF MRA、silent MRA和诊断性脑血管造影;以DSA为金标准,比较两种MRA序列对瘘口大小、位置、引流静脉和侧支沟通动脉的分析。

关键影像表现/征象

  • TOF MRA识别瘘口位置的敏感度为76.9%,silent MRA为69.2%。
  • TOF MRA正确 pinpoint 瘘口位置的比例为93.3%,silent MRA为73.3%。
  • 两种MRA序列对原发瘤囊和瘘口大小的评估与DSA均显示良好一致性。
  • TOF MRA正确识别210个静脉结构中的86.2%,silent MRA识别96%。
  • silent MRA显示受累静脉的敏感度为90%,TOF MRA为76%;准确率分别为87.69和94.36。

诊断标准与关键数值

  • 以DSA为金标准,TOF MRA识别瘘口位置的敏感度为76.9%,silent MRA为69.2%。
  • TOF MRA瘘口定位准确率为93.3%,silent MRA为73.3%。
  • TOF MRA正确识别210个静脉结构中的86.2%,silent MRA识别96%。
  • silent MRA显示受累静脉的敏感度为90%,TOF MRA为76%;准确率silent MRA为87.69,TOF MRA为94.36。

临床应用与阅片要点

  • 作者认为联合TOF与silent MRA可评估DCCF多种血管构筑特征,有助于治疗规划。
  • 原文指出,对于高风险病例,MRA这类侵入性较小的方式可能有用。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Endovascular treatment of direct carotid cavernous fistula (DCCF) requires invasive diagnostic cerebral angiography for diagnosis and planning; however, a less invasive modality like magnetic resonance angiography (MRA) can be useful, especially in high-risk cases. This single-centre study evaluated a newer MR angiography (MRA) sequence, silent MRA and the traditional time of flight (TOF) MRA for pre-procedural treatment planning of DCCF.

METHODS: All consecutive DCCF patients who underwent TOF, silent MRA and diagnostic cerebral angiography were included in the study. Angiographic features like rent size, location, draining veins and collateral communicating arteries were analysed and compared between the two MRA sequences, with digital subtraction angiography (DSA) as the gold standard.

RESULTS: Fifteen patients were included in the study. TOF MRA exhibited better sensitivity (76.9% vs 69.2%) in identifying the rent location, correctly pinpointing the location in 93.3% compared to 73.3% with silent MRA. Both MRA sequences showed good agreement with DSA for primary sac and rent size. TOF MRA correctly identified 86.2% of 210 total venous structures compared to 96% by silent MRA. Silent MRA demonstrated higher sensitivity (90% vs 76%) and accuracy (87.69 vs 94.36) in visualisation of involved veins compared to TOF MRA.

CONCLUSION: Arterial characteristics of DCCF like rent location and rent size were better assessed by TOF MRA. Although both MRA identified venous features, silent MRA correlated better with DSA irrespective of the size and proximity to the site of the fistula. Combining both sequences can evaluate various angioarchitectural features of DCCF useful for therapeutic planning.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Mishra D, Kannath SK, Er J, et al. Evaluating the diagnostic performance of non-contrast magnetic resonance angiography sequences in the pre-procedural comprehensive analysis of direct carotid cavernous fistula. Neuroradiology. 2024. PMID: 38581636. doi:10.1007/s00234-024-03342-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。