文献速递骨肌MR

深度学习重建加速膝关节磁共振成像序列采集:一项志愿者研究

Faster acquisition of magnetic resonance imaging sequences of the knee via deep learning reconstruction: a volunteer study.
PubMed 文献 · Clin Radiol · 2024-03-26

研究纳入27名健康志愿者,在1.5-T MRI上比较1次信号平均(1NSA)、深度学习重建(1DLR)与4次信号平均(4NSA)的膝关节矢状面fs-T2WI、冠状面PDWI和T1WI图像。1DLR三序列采集在200秒内完成(4NSA约12分钟)。PDWI 1DLR图像质量优于4NSA,fs-T2WI和T1WI的1DLR与4NSA图像质量相似。

要点

  • PDWI 1DLR图像主观及客观质量均优于PDWI 4NSA图像。
  • fs-T2WI和T1WI的1DLR与4NSA图像质量无差异。
  • 1DLR三序列采集可在200秒内完成,4NSA约需12分钟。

核心结论

  • 与PDWI 4NSA图像相比,PDWI 1DLR图像质量更高;fs-T2WI和T1WI的1DLR图像质量与4NSA图像相似。

研究设计与样本

  • 志愿者研究,纳入27名健康志愿者(年龄40.6 ± 11.9岁),使用1.5-T MRI扫描仪,采集矢状面脂肪抑制T2加权成像(fs-T2WI)、冠状面质子密度加权成像(PDWI)和冠状面T1加权成像(T1WI),比较1NSA、1DLR和4NSA图像。

诊断标准与关键数值

  • 客观评价:PDWI 1DLR图像噪声最小,对比度显著高于1NSA和4NSA图像。
  • 客观评价:fs-T2WI噪声由小到大及对比度由高到低依次为4NSA、1DLR、1NSA图像。
  • 主观分析:PDWI 1DLR的结构可见度、图像噪声和整体图像质量显著优于1NSA图像。
  • 主观分析:1DLR的半月板和骨骼可见度、图像噪声和整体图像质量显著优于4NSA图像。
  • fs-T2WI和T1WI的1DLR与4NSA图像之间无差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate whether deep learning reconstruction (DLR) can accelerate the acquisition of magnetic resonance imaging (MRI) sequences of the knee for clinical use.

MATERIALS AND METHODS: Using a 1.5-T MRI scanner, sagittal fat-suppressed T2-weighted imaging (fs-T2WI), coronal proton density-weighted imaging (PDWI), and coronal T1-weighted imaging (T1WI) were performed. DLR was applied to images with a number of signal averages (NSA) of 1 to obtain 1DLR images. Then 1NSA, 1DLR, and 4NSA images were compared subjectively, and by noise (standard deviation of intra-articular water or medial meniscus) and contrast-to-noise ratio between two anatomical structures or between an anatomical structure and intra-articular water.

RESULTS: Twenty-seven healthy volunteers (age: 40.6 ± 11.9 years) were enrolled. Three 1DLR image sequences were obtained within 200 s (approximately 12 minutes for 4NSA image). According to objective evaluations, PDWI 1DLR images showed the smallest noise and significantly higher contrast than 1NSA and 4NSA images. For fs-T2WI, smaller noise and higher contrast were observed in the order of 4NSA, 1DLR, and 1NSA images. According to the subjective analysis, structure visibility, image noise, and overall image quality were significantly better for PDWI 1DLR than 1NSA images; moreover, the visibility of the meniscus and bone, image noise, and overall image quality were significantly better for 1DLR than 4NSA images. Fs-T2WI and T1WI 1DLR images showed no difference between 1DLR and 4NSA images.

CONCLUSION: Compared to PDWI 4NSA images, PDWI 1DLR images were of higher quality, while the quality of fs-T2WI and T1WI 1DLR images was similar to that of 4NSA images.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Akai H, Yasaka K, Sugawara H, et al. Faster acquisition of magnetic resonance imaging sequences of the knee via deep learning reconstruction: a volunteer study. Clin Radiol. 2024. PMID: 38614869. doi:10.1016/j.crad.2024.03.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。