儿童关节炎患者膝关节MRI测量滑膜厚度:是否需要对比剂?
该回顾性研究纳入35例幼年特发性关节炎患儿共38次膝关节MRI,由两名放射科医生在6个膝关节部位独立测量增强与非增强序列的滑膜厚度,并以JAMRIS系统进行等级评分。结果显示非增强MRI在评估滑膜厚度方面与增强MRI等效,但对比剂有助于提高读者间可靠性。
要点
- 非增强膝关节MRI在6个部位测量滑膜厚度与增强MRI等效(连续测量与等级评分P值均<0.05)。
- 读者内可靠性为中到高(CCC 0.50-0.89),但交叉韧带部位除外。
- 读者间可靠性非增强序列低(CCC 0.47,95%CI 0.41-0.53),增强序列中等(CCC 0.64,95%CI 0.59-0.69)。
核心结论
- 使用常规MRI序列时,非增强膝关节MRI在评估滑膜厚度方面与增强MRI等效;对比剂有助于提高读者间可靠性。
研究设计与样本
- 经机构审查委员会批准的回顾性研究,在一家三级儿童医院进行;纳入2012年1月至2022年1月期间接受1.5 T或3 T膝关节MRI(平扫加增强)的21岁以下幼年特发性关节炎患者,共35例患者38次检查(25例女性,中位年龄14岁,四分位距7至15.7);两名放射科医生独立在6个膝关节部位测量滑膜厚度,记录数值测量和基于JAMRIS系统的等级评分,进行等效性检验及读者间和读者内可靠性分析(CCC),所有检验显著性水平为5%。
诊断标准与关键数值
- 基于两名读者平均值,6个部位在连续测量(P值均<0.05)和等级评分(P值均<0.05)上均显示等效;读者内可靠性CCC为0.50-0.89(交叉韧带部位除外);读者间可靠性:非增强序列CCC 0.47(95%CI 0.41-0.53),增强序列CCC 0.64(95%CI 0.59-0.69)。
临床应用与阅片要点
- 作者结论认为,使用常规MRI序列时非增强膝关节MRI在评估滑膜厚度方面与增强MRI等效;对比剂有助于提高读者间可靠性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The use of contrast-enhanced imaging has long been standard for magnetic resonance imaging (MRI) assessments of synovitis in juvenile idiopathic arthritis (JIA). However, advancements in MRI technology have allowed for reliable identification of synovium without contrast.
OBJECTIVE: To assess the equivalence of unenhanced MRI with contrast-enhanced MRI in evaluating synovial thickness.
MATERIALS AND METHODS: This is an institutional review board approved, retrospective study performed in a tertiary children's hospital. Pediatric JIA patients under 21 years old were included who underwent knee MRI scans (1.5 T or 3 T) without and with contrast between January 2012 and January 2022. Two radiologists independently measured synovial thickness at 6 knee sites on contrast-enhanced and unenhanced sequences. Numerical measurements and ordinal scores based on juvenile idiopathic arthritis magnetic resonance imaging scoring (JAMRIS) system were recorded, and tests of equivalence were conducted, as well as between-reader and within-reader reliability by concordance correlation coefficient (CCC). All tests were considered significant at the 5% level.
RESULTS: A total of 38 studies from 35 patients (25 females, median age 14 years; interquartile range 7 to 15.7) were included. Equivalence was demonstrated at each of the 6 sites for both continuous measurements (P-values < 0.05) and ordinal scores (P-values < 0.05) based on the average over readers. Within-reader reliability was moderate to high (CCC 0.50-0.89), except for the cruciate ligaments site. Averaged over the 6 sites, reliability between readers was low for unenhanced (CCC 0.47, with 95% CI: [0.41, 0.53]) and moderate for contrast-enhanced (CCC 0.64, with 95% CI: [0.59, 0.69]) sequences.
CONCLUSION: Unenhanced knee MRI is equivalent to contrast-enhanced MRI in assessment of synovial thickness using conventional MRI sequences. Contrast material helped improve inter-reader reliability.
引用
- Handa A, Bedoya MA, Iwasaka-Neder J, et al. Measuring synovial thickness on knee MRI in pediatric patients with arthritis: is contrast necessary? Pediatr Radiol. 2024. PMID: 38641735. doi:10.1007/s00247-024-05929-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。