在DENSE试验中自动评估极密乳腺MRI背景实质强化且不削弱其与乳腺癌的关联
本研究为DENSE试验的二次分析,纳入八家医院4553例接受补充乳腺MRI筛查的极密乳腺女性,提取15个纤维腺体组织定量特征,用随机森林、朴素贝叶斯和KNN分类器预测背景实质强化(BPE)类别并以多数投票整合。八家医院多数投票准确率0.56–0.84,四类BPE加权平均准确率0.76;自动评估与人工评估的BPE与乳腺癌发生关联相当(HR=2.12 vs HR=1.97,P=0.65,轻度/中度/显著BPE相对于极低BPE)。
要点
- 极密乳腺DCE-MRI中自动评估BPE四类加权平均准确率0.76。
- 自动评估BPE与乳腺癌发生的HR=2.12,人工评估HR=1.97,P=0.65。
- 极低BPE的自动评估准确率优于其他BPE类别。
核心结论
- 在极密乳腺女性DCE-MRI中自动评估BPE可行,且不削弱BPE与乳腺癌发生的关联;极低BPE的准确率优于其他BPE类别。
研究设计与样本
- DENSE试验二次分析,纳入八家医院4553例接受补充乳腺MRI筛查的极密乳腺女性;以放射科医生评定的极低、轻度、中度、显著BPE为参考,提取15个纤维腺体组织定量MRI特征,用随机森林、朴素贝叶斯和KNN分类器预测BPE并以多数投票整合,采用内部-外部验证进行训练和验证。
诊断标准与关键数值
- 八家医院多数投票准确率范围0.56–0.84,四类BPE加权平均预测准确率0.76。
- 自动评估BPE与乳腺癌发生的HR=2.12,人工评估HR=1.97,P=0.65(轻度/中度/显著BPE相对于极低BPE)。
临床应用与阅片要点
- 自动评估BPE可用于极密乳腺DCE-MRI,且不削弱BPE与乳腺癌发生的关联。
- 极低BPE的自动评估准确率优于其他BPE类别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Background parenchymal enhancement (BPE) on dynamic contrast-enhanced MRI (DCE-MRI) as rated by radiologists is subject to inter- and intrareader variability. We aim to automate BPE category from DCE-MRI.
METHODS: This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial. 4553 women with extremely dense breasts who received supplemental breast MRI screening in eight hospitals were included. Minimal, mild, moderate and marked BPE rated by radiologists were used as reference. Fifteen quantitative MRI features of the fibroglandular tissue were extracted to predict BPE using Random Forest, Naïve Bayes, and KNN classifiers. Majority voting was used to combine the predictions. Internal-external validation was used for training and validation. The inverse-variance weighted mean accuracy was used to express mean performance across the eight hospitals. Cox regression was used to verify non inferiority of the association between automated rating and breast cancer occurrence compared to the association for manual rating.
RESULTS: The accuracy of majority voting ranged between 0.56 and 0.84 across the eight hospitals. The weighted mean prediction accuracy for the four BPE categories was 0.76. The hazard ratio (HR) of BPE for breast cancer occurrence was comparable between automated rating and manual rating (HR = 2.12 versus HR = 1.97, P = 0.65 for mild/moderate/marked BPE relative to minimal BPE).
CONCLUSION: It is feasible to rate BPE automatically in DCE-MRI of women with extremely dense breasts without compromising the underlying association between BPE and breast cancer occurrence. The accuracy for minimal BPE is superior to that for other BPE categories.
引用
- Wang H, H M van der Velden B, Verburg E, et al. Automated rating of background parenchymal enhancement in MRI of extremely dense breasts without compromising the association with breast cancer in the DENSE trial. Eur J Radiol. 2024. PMID: 38583349. doi:10.1016/j.ejrad.2024.111442
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。