文献速递泌尿生殖腹部MR

基于深度学习重建的膀胱MRI:应用VI-RADS前瞻性评估肌层浸润

Bladder MRI with deep learning-based reconstruction: a prospective evaluation of muscle invasiveness using VI-RADS.
PubMed 文献 · Abdom Radiol (NY) · 2024-04-23

该前瞻性研究纳入70例膀胱癌患者,比较标准T2WI和DWI与深度学习重建(DLR)快速序列的图像质量、ADC值及VI-RADS诊断肌层浸润的效能。DLR将采集时间从5:57 min缩短至3:13 min,并显著提高SNR、CNR及主观图像质量评分,ADC值与VI-RADS的AUC在标准序列与DLR快速序列间无显著差异。

要点

  • DLR使T2WI和DWI采集时间从5:57 min降至3:13 min。
  • DLR序列的SNR、CNR及图像质量评分显著高于标准序列。
  • 标准序列与DLR序列的ADC值及VI-RADS诊断肌层浸润的AUC无显著差异。

核心结论

  • 将DLR应用于T2WI和DWI可缩短检查时间并显著改善图像质量,同时维持ADC值和VI-RADS评估膀胱癌肌层浸润的诊断效能。

研究设计与样本

  • 前瞻性临床队列研究,纳入2022年8月至2023年2月间接受膀胱MRI的70例膀胱癌患者,采用包含标准T2WI、标准DWI、DLR快速T2WI和DLR快速DWI的协议,以VI-RADS评分评估肌层浸润,采用受试者工作特征曲线下面积(AUC)评价诊断效能。

关键影像表现/征象

  • DLR快速T2WI和DWI较标准T2WI和DWI显著提高SNR、CNR以及整体图像质量、图像锐利度和病灶清晰度的定性评分。

诊断标准与关键数值

  • 标准序列与DLR快速序列的ADC值无显著差异。
  • 标准序列与DLR快速序列的VI-RADS诊断肌层浸润的AUC无显著差异。

临床应用与阅片要点

  • DLR快速T2WI和DWI可在缩短采集时间的同时维持VI-RADS评估肌层浸润的诊断效能,并改善图像质量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the influence of deep learning reconstruction (DLR) on bladder MRI, specifically examination time, image quality, and diagnostic performance of vesical imaging reporting and data system (VI-RADS) within a prospective clinical cohort.

METHODS: Seventy participants with bladder cancer who underwent MRI between August 2022 and February 2023 with a protocol containing standard T2-weighted imaging (T2WIS), standard diffusion-weighted imaging (DWIS), fast T2WI with DLR (T2WIDL), and fast DWI with DLR (DWIDL) were enrolled in this prospective study. Imaging quality was evaluated by measuring signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and qualitative image quality scoring. Additionally, the apparent diffusion coefficient (ADC) of bladder lesions derived from DWIS and DWIDL was measured and VI-RADS scoring was performed. Paired t-test or paired Wilcoxon signed-rank test were performed to compare image quality score, SNR, CNR, and ADC between standard sequences and fast sequences with DLR. The diagnostic performance for VI-RADS was assessed using the area under the receiver operating characteristic curve (AUC).

RESULTS: Compared to T2WIS and DWIS, T2WIDL and DWIDL reduced the acquisition time from 5:57 min to 3:13 min and showed significantly higher SNR, CNR, qualitative image quality score of overall image quality, image sharpness, and lesion conspicuity. There were no significant differences in ADC and AUC of VI-RADS between standard sequences and fast sequences with DLR.

CONCLUSIONS: The application of DLR to T2WI and DWI reduced examination time and significantly improved image quality, maintaining ADC and the diagnostic performance of VI-RADS for evaluating muscle invasion in bladder cancer.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang X, Wang Y, Xu X, et al. Bladder MRI with deep learning-based reconstruction: a prospective evaluation of muscle invasiveness using VI-RADS. Abdom Radiol (NY). 2024. PMID: 38652125. doi:10.1007/s00261-024-04280-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。