胰腺癌可切除性评估的光子计数CT与能量积分探测器CT的阅片者间一致性比较
回顾性单中心研究纳入145例胰腺腺癌患者,比较胰腺方案光子计数CT(PCCT)与常规能量积分探测器CT(EID-CT)评估可切除性的阅片者间一致性。PCCT在腹腔干、肠系膜上动脉、肠系膜上静脉受累及转移灶识别上呈显著一致性,EID-CT为中等一致性;PCCT的CTDIvol为16.9 mGy,EID-CT为29.8 mGy(p < .001)。
要点
- PCCT在5根主要胰周血管中的4根(腹腔干、肠系膜上动脉、肝总动脉、肠系膜上静脉)受累评估呈显著一致性,EID-CT仅2根。
- PCCT转移灶识别为显著一致性(κ=0.78),EID-CT为中等一致性(κ=0.56)。
- PCCT的CTDIvol为16.9 mGy,低于EID-CT的29.8 mGy(p < .001)。
核心结论
- PCCT在4/5主要胰周血管受累及转移灶识别上呈显著阅片者间一致性,EID-CT分别为2/5和中等一致性,且PCCT辐射剂量显著降低。
研究设计与样本
- 回顾性单中心数据库检索,纳入2022年4月11日至2022年10月30日门诊行胰腺肿块方案腹部增强CT且同时有PCCT和EID-CT的145例胰腺腺癌患者(71例男性,平均[SD]年龄66[9]岁)。
诊断标准与关键数值
- 血管受累分级:未受累、接触≤180°、包绕>180°;评估血管包括腹腔干、肠系膜上动脉、肝总动脉、肠系膜上静脉、门静脉主干;总体可切除性分为可切除、交界可切除、局部晚期、转移性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the inter-reader agreement of pancreatic adenocarcinoma resectability assessment at pancreatic protocol photon-counting CT (PCCT) with conventional energy-integrating detector CT (EID-CT).
METHODS: A retrospective single institution database search identified all contrast-enhanced pancreatic mass protocol abdominal CT performed at an outpatient facility with both a PCCT and EID-CT from 4/11/2022 to 10/30/2022. Patients without pancreatic adenocarcinoma were excluded. Four fellowship-trained abdominal radiologists, blinded to CT type, independently assessed vascular tumor involvement (uninvolved, abuts ≤ 180°, encases > 180°; celiac, superior mesenteric artery (SMA), common hepatic artery (CHA), superior mesenteric vein (SMV), main portal vein), the presence/absence of metastases, overall tumor resectability (resectable, borderline resectable, locally advanced, metastatic), and diagnostic confidence. Fleiss's kappa was used to calculate inter-reader agreement. CTDIvol was recorded. Radiation dose metrics were compared with a two-sample t-test. A p < .05 indicated statistical significance.
RESULTS: 145 patients (71 men, mean[SD] age: 66[9] years) were included. There was substantial inter-reader agreement, for celiac artery, SMA, and SMV involvement at PCCT (kappa = 0.61-0.69) versus moderate agreement at EID-CT (kappa = 0.56-0.59). CHA had substantial inter-reader agreement at both PCCT (kappa = 0.67) and EIDCT (kappa = 0.70). For metastasis identification, radiologists had substantial inter-reader agreement at PCCT (kappa = 0.78) versus moderate agreement at EID-CT (kappa = 0.56). CTDIvol for PCCT and EID-CT were 16.9[7.4]mGy and 29.8[26.6]mGy, respectively (p < .001).
CONCLUSION: There was substantial inter-reader agreement for involvement of 4/5 major peripancreatic vessels (celiac artery, SMA, CHA, and SMV) at PCCT compared with 2/5 for EID-CT. PCCT also afforded substantial inter-reader agreement for metastasis detection versus moderate agreement at EID-CT with statistically significant radiation dose reduction.
引用
- Kim J, Mabud T, Huang C, et al. Inter-reader agreement of pancreatic adenocarcinoma resectability assessment with photon counting versus energy integrating detector CT. Abdom Radiol (NY). 2024. PMID: 38630314. doi:10.1007/s00261-024-04298-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。