文献速递腹部技术与安全CT

双能CT定量参数用于术前评估进展期胃癌隐匿性腹膜转移

Dual-energy CT quantitative parameters to evaluate occult peritoneal metastasis in advanced gastric cancer preoperatively.
PubMed 文献 · Abdom Radiol (NY) · 2024-04-18

回顾性纳入219例进展期胃癌并接受双能CT扫描的患者,比较无腹膜转移、隐匿性腹膜转移与影像学腹膜转移组的碘浓度参数及有效原子序数。双能CT参数列线图诊断隐匿性腹膜转移的AUC-PR为0.884,优于常规CT征象Borrmann IV型(0.368)和血清CA125(0.189),与三者联合指标的0.918相近。

要点

  • 双能CT碘浓度、标准化碘浓度及有效原子序数在腹膜转移组低于无腹膜转移组。
  • 双能CT三参数列线图诊断隐匿性腹膜转移AUC-PR为0.884,优于Borrmann IV型(0.368)和CA125(0.189)。
  • 双能CT列线图与双能CT+常规CT征象+CA125联合指标AUC-PR相近(0.884 vs 0.918)。

核心结论

  • 双能CT定量参数标准化碘浓度、碘浓度比值及有效原子序数降低与进展期胃癌腹膜转移相关,有希望用于无创识别隐匿性腹膜转移患者。

研究设计与样本

  • 回顾性研究,纳入219例进展期胃癌并接受双能CT扫描的患者,比较无腹膜转移组、隐匿性腹膜转移组和影像学腹膜转移组的临床资料及双能CT碘浓度参数和有效原子序数。

关键影像表现/征象

  • 双能CT参数碘浓度、标准化碘浓度和有效原子序数在腹膜转移组低于无腹膜转移组。
  • CT诊断的Borrmann IV型和血清肿瘤指标CA125在无腹膜转移组与隐匿性腹膜转移组间差异有统计学意义。

诊断标准与关键数值

  • 双能CT三参数列线图诊断隐匿性腹膜转移的AUC-PR为0.884,常规CT征象Borrmann IV型为0.368,血清CA125为0.189。
  • 双能CT参数联合常规CT征象Borrmann IV型及血清CA125的联合指标AUC-PR为0.918。

临床应用与阅片要点

  • 双能CT定量参数标准化碘浓度、碘浓度比值及有效原子序数降低可能提示进展期胃癌患者存在腹膜转移。
  • 双能CT三参数列线图诊断隐匿性腹膜转移的AUC-PR为0.884,优于常规CT征象Borrmann IV型(0.368)和血清CA125(0.189)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To explore whether dual-energy CT (DECT) quantitative parameters could provide analytic value for the diagnosis of patients with occult peritoneal metastasis (OPM) in advanced gastric cancer preoperatively.

MATERIALS AND METHODS: This retrospective study included 219 patients with advanced gastric cancer and DECT scans. The patient's clinical data and DECT related iodine concentration (IC) parameters and effective atomic number (Zeff) were collated and analyzed among noun-peritoneal metastasis (NPM), OPM and radiologically peritoneal metastasis (RPM) groups. The predictive performance of the DECT parameters was compared with that of the conventional CT features and clinical characteristics through evaluating area under curve of the precision-recall (AUC-PR), F1 score, balanced accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV).

RESULTS: Borrmann IV type diagnosed on CT and serum tumor indicator CA125 index were statistically different between the NPM and OPM groups. DECT parameters included IC, normalized IC (NIC), and Zeff of PM group were lower than the NPM group. The DECT predictive nomogram combined three independent DECT parameters produced a better diagnostic performance than the conventional CT feature Borrmann IV type and serum CA125 index in AUC-PR with 0.884 vs 0.368 vs 0.189, but similar to the combined indicator which was based on the DECT parameters, the conventional CT feature, and serum CA125 index in AUC-PR with 0.884 vs 0.918.

CONCLUSION: The lower quantitative NIC, IC ratio, and Zeff on DECT was associated with peritoneal metastasis in advanced gastric cancer and was promising to identify patients with OPM noninvasively.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Feng QX, Zhu ZN, Li Q, et al. Dual-energy CT quantitative parameters to evaluate occult peritoneal metastasis in advanced gastric cancer preoperatively. Abdom Radiol (NY). 2024. PMID: 38634880. doi:10.1007/s00261-024-04303-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。