文献速递腹部介入MRDSA

基于深度学习的动脉期减影图像提高细胞外对比剂增强MRI上LR-TR算法检测存活HCC的效能

Deep learning-based arterial subtraction images improve the detection of LR-TR algorithm for viable HCC on extracellular agents-enhanced MRI.
PubMed 文献 · Abdom Radiol (NY) · 2024-04-20

回顾性纳入105例接受局部治疗的HCC患者共286个观察灶,构建深度学习减影模型自动生成动脉期减影图像。加入减影图像后,LR-TR算法检测存活HCC的敏感度从67.5%升至87.9%(P<0.001),准确率从75.9%升至86.4%(P<0.001),AUC从0.768升至0.862(P<0.001),特异度无显著变化(84.5% vs 86.0%,P=0.687),读者间一致性提高(0.857 vs 0.727)。

要点

  • 深度学习动脉期减影图像可显著提高LR-TR算法检测存活HCC的敏感度(87.9% vs 67.5%)和AUC(0.862 vs 0.768)。
  • 加入减影图像后特异度无显著变化(84.5% vs 86.0%,P=0.687),读者间一致性由0.727升至0.857。
  • 减影图像可作为细胞外对比剂增强MRI评估HCC存活性的辅助工具。

核心结论

  • 在细胞外对比剂增强MRI上扩展应用基于深度学习的动脉期减影图像,可提高LR-TR算法检测存活HCC的敏感度,而不引起特异度的显著变化。

研究设计与样本

  • 回顾性收集接受局部治疗的HCC患者,最终纳入105例患者共286个观察灶。
  • 构建基于深度学习的减影模型并自动生成动脉期减影图像。
  • 两名放射科医师先在常规图像上评估LR-TR分类,经过2个月洗脱期后再在常规图像加动脉期减影图像上重新评估。
  • 存活性的参考标准为MRI后1个月内数字减影肝动脉造影上的肿瘤染色。

关键影像表现/征象

  • 根据参考标准,157个观察灶为存活,129个观察灶为非存活。

诊断标准与关键数值

  • LR-TR算法检测存活HCC的敏感度:应用动脉期减影图像后87.9%,未应用时67.5%(P<0.001)。
  • LR-TR算法检测存活HCC的准确率:应用动脉期减影图像后86.4%,未应用时75.9%(P<0.001)。
  • LR-TR算法检测存活HCC的特异度:应用动脉期减影图像后84.5%,未应用时86.0%(P=0.687),差异无统计学意义。
  • LR-TR算法的AUC:应用动脉期减影图像后0.862,未应用时0.768(P<0.001)。
  • 读者间一致性:应用动脉期减影图像后0.857,未应用时0.727。

临床应用与阅片要点

  • 在细胞外对比剂增强MRI上评估HCC局部治疗后存活时,可结合深度学习自动生成的动脉期减影图像辅助LR-TR分类。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the role of deep learning-based arterial subtraction images in viability assessment on extracellular agents-enhanced MRI using LR-TR algorithm.

METHODS: Patients diagnosed with HCC who underwent locoregional therapy were retrospectively collected. We constructed a deep learning-based subtraction model and automatically generated arterial subtraction images. Two radiologists evaluated LR-TR category on ordinary images and then evaluated again on ordinary images plus arterial subtraction images after a 2-month washout period. The reference standard for viability was tumor stain on the digital subtraction hepatic angiography within 1 month after MRI.

RESULTS: 286 observations of 105 patients were ultimately enrolled. 157 observations were viable and 129 observations were nonviable according to the reference standard. The sensitivity and accuracy of LR-TR algorithm for detecting viable HCC significantly increased with the application of arterial subtraction images (87.9% vs. 67.5%, p < 0.001; 86.4% vs. 75.9%, p < 0.001). And the specificity slightly decreased without significant difference when the arterial subtraction images were added (84.5% vs. 86.0%, p = 0.687). The AUC of LR-TR algorithm significantly increased with the addition of arterial subtraction images (0.862 vs. 0.768, p < 0.001). The arterial subtraction images also improved inter-reader agreement (0.857 vs. 0.727).

CONCLUSION: Extended application of deep learning-based arterial subtraction images on extracellular agents-enhanced MRI can increase the sensitivity of LR-TR algorithm for detecting viable HCC without significant change in specificity.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Wang Y, Yang D, Xu L, et al. Deep learning-based arterial subtraction images improve the detection of LR-TR algorithm for viable HCC on extracellular agents-enhanced MRI. Abdom Radiol (NY). 2024. PMID: 38642094. doi:10.1007/s00261-024-04277-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。