进食或饮水是否影响超声衰减系数估计

Does Meal or Water Intake Affect Ultrasound Attenuation Coefficient Estimate?
PubMed 文献 · J Ultrasound Med · 2024-04-22

在意大利和美国两个中心纳入26人,用Aplio i系列超声的ATI算法测量肝衰减系数,分别于饮水500 mL后5、15、30、45分钟和进食约600 kcal后30、45、60、90、120分钟复测。饮水和进食后各时间点衰减系数与基线均无显著差异,提示测衰减系数无需空腹且饮水不影响结果。

要点

  • 饮水500 mL后5至45分钟各时间点肝衰减系数与基线无显著差异。
  • 进食约600 kcal后30至120分钟各时间点肝衰减系数与基线无显著差异。
  • 衰减系数是肝脂肪含量的生物标志物,测量时无需空腹状态,饮水不影响结果。

核心结论

  • 肝衰减系数测量不要求空腹,饮水不影响测量结果;纳入性别、年龄和皮肤至肝包膜距离后结论不变。

研究设计与样本

  • 两中心(意大利和美国)研究,共纳入26人(意大利11人,美国15人),使用Aplio i系列超声系统的ATI算法,由每个中心各一名操作者测量,采用多水平广义估计方程分析重复测量数据。

关键影像表现/征象

  • B型超声显示10人(38.5%)存在肝脂肪变。
  • 基线衰减系数(分贝/厘米/兆赫)在饮水组为0.64(0.12),在进食组为0.66(0.13)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess whether meal or water intake may affect the measurement of the ultrasound (US) attenuation coefficient (AC) imaging, a parameter that is directly related to liver fat content.

METHODS: The study was performed in two centers (Italy and USA). AC was obtained using the ATI algorithm implemented in the Aplio i-series US systems (Canon Medical Systems, Japan) by one operator at each center. Measurements were performed at baseline and 5, 15, 30, 45 minutes after drinking 500 mL of water (group 1), or 30, 45, 60, 90, 120 minutes after eating a meal of about 600 kcal (group 2). Multilevel generalized estimating equations for repeated measures were used for the statistical analysis to consider the clustered nature of the data.

RESULTS: Twenty-six individuals were enrolled: 11 (10 females; age, 43.7 ± 12.5 years) in Italy and 15 (10 females; age, 60.7 ± 6.3 years) in USA. At B-mode US, 10 (38.5%) had liver steatosis. The baseline AC values, in decibel/centimeter/megahertz, were 0.64 (0.12) in group 1 and 0.66 (0.13) in group 2. There was not any significant difference in AC values at every time-point after water or meal intake either in group 1 or group 2. This result did not change including sex, age, and skin-to-liver capsule into the models.

CONCLUSIONS: The measurement of the AC, which is a biomarker of liver steatosis, does not require a fasting state and drinking water does not affect the result.

来源:J Ultrasound Med,查看原文。版权归原作者所有。