文献速递腹部介入US

应变弹性成像在肝门部胆管癌活检中的潜在价值

Unveiling the potential of strain elastography in perihilar cholangiocarcinoma biopsies.
PubMed 文献 · Abdom Radiol (NY) · 2024-04-01

回顾性分析23例疑似肝门部胆管癌的肝脏活检,评估应变弹性成像引导穿刺取材的效果。弹性成像引导活检无需重复穿刺,而灰阶超声引导活检有4例需再次活检才诊断胆管癌(P=0.037)。应变指数值观察者间和观察者内一致性强(P<0.001),但良恶性肝脏肿块的应变指数值重叠明显,限制了该技术的临床实用性。

要点

  • 弹性成像引导肝门部胆管癌活检可减少重复穿刺,灰阶超声引导有4例需再次活检(P=0.037)。
  • 应变指数值在良恶性肝脏肿块间重叠明显,限制其临床鉴别价值。
  • 弹性成像对等回声病灶的穿刺准确性可能更高,但需结合灰阶超声综合判断。

核心结论

  • 弹性成像可提高疑难等回声病灶的活检准确性,但良恶性肝脏肿块应变指数值重叠明显,限制该技术的临床实用性。

研究设计与样本

  • 回顾性分析纳入2019年3月至2022年7月间23例疑似肝门部胆管癌的肝脏活检,由经验丰富的放射科医生使用配备弹性成像的超声设备完成,以组织硬度彩色图引导活检,并在记录图像上计算应变指数值。

关键影像表现/征象

  • 灰阶超声显示肝脏病灶回声特征多样。
  • 弹性成像引导活检无需重复穿刺,灰阶超声引导活检有4例需再次活检才诊断胆管癌(P=0.037)。
  • 两组均未出现活检后并发症。

诊断标准与关键数值

  • 应变指数值观察者间和观察者内一致性强(P<0.001)。
  • 良恶性肝脏肿块应变指数值重叠明显,限制临床实用性。

临床应用与阅片要点

  • 弹性成像引导可能有助于减少肝门部胆管癌活检的重复穿刺,尤其对等回声病灶。
  • 应变指数值良恶性重叠明显,阅片时需结合灰阶超声和其他临床信息综合判断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study was conducted to investigate the effectiveness of strain elastography in guiding precise and sufficient tissue sampling for perihilar cholangiocarcinoma (CCA) biopsies.

METHODS: Our retrospective analysis included 23 liver biopsies conducted between March 2019 and July 2022 for suspected perihilar CCA. An experienced radiologist performed the biopsies via an ultrasound machine with elastography configuration. Tissue stiffness color maps were used for guiding when the biopsies were performed. Strain index value calculations were made by radiologists on recorded images.

RESULTS: Patient demographics revealed a mean age of 65.17 ± 9.25 years, with a gender distribution of six females and 17 males. Gray-scale examinations unveiled diverse echogenic characteristics in liver lesions. Elastography-guided biopsies demonstrated no need for repeats, while gray-scale biopsies necessitated re-biopsy in four patients, resulting in cholangiocarcinoma diagnosis (P = 0.037). Strain index values showcased strong inter- and intra-observer agreements (P < 0.001). Notably, no post-biopsy complications emerged in either study group.

CONCLUSION: The diagnostic advantage of elastography, particularly in enhancing accuracy in challenging isoechoic lesions, was demonstrated, although the substantial overlap between strain index values of benign and malignant liver masses limits clinical usefulness of this technique.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Özdemir M, Koç U, Gökhan MB, et al. Unveiling the potential of strain elastography in perihilar cholangiocarcinoma biopsies. Abdom Radiol (NY). 2024. PMID: 38557769. doi:10.1007/s00261-024-04255-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。