文献速递心血管CT

大型学术医学中心选择性使用CT血流储备分数的实践:实施一年后的临床洞察

Selective Use of CT Fractional Flow at a Large Academic Medical Center: Insights from Clinical Implementation after 1 Year of Practice.
PubMed 文献 · Radiol Cardiothorac Imaging · 2024-01-01

本回顾性观察研究纳入2020年8月至2021年8月临床指征行冠状动脉CTA的2985例患者,其中292例(9.7%)转诊行CT-FFR分析,采用双源冠状动脉CTA在无心率控制下于收缩晚期至舒张早期采集。在显著狭窄患者中,行CT-FFR分析者ICA率(74.5% vs 25.5%,P=0.04)和PCI率(78.9% vs 21.1%,P=0.05)较低,作者认为CT-FFR在不影响安全性的情况下可能降低ICA和PCI率。

要点

  • 无心率控制双源冠状动脉CTA可用于CT-FFR分析,平均心率65次/分。
  • 显著狭窄患者中,CT-FFR组ICA率25.5%低于未行CT-FFR组的74.5%(P=0.04)。
  • 显著狭窄患者中,CT-FFR组PCI率21.1%低于未行CT-FFR组的78.9%(P=0.05)。

核心结论

  • CT-FFR通过双源冠状动脉CTA在无需心率控制的患者中实施,在显著狭窄且平均心率65次/分的患者中显示出降低ICA和PCI率的潜力且不损害安全性。

研究设计与样本

  • 回顾性观察研究,纳入2020年8月至2021年8月所有临床指征行冠状动脉CTA的患者,排除113例冠状动脉旁路移植术后患者后共2985例,采用双源冠状动脉CTA于收缩晚期至舒张早期采集且无心率控制,由判读医师酌情决定是否行CT-FFR分析。

关键影像表现/征象

  • 冠状动脉CTA扫描于收缩晚期至舒张早期采集,未进行心率控制。
  • 292例(9.7%)转诊行CT-FFR分析,其中2例(0.7%)分析被拒绝,6例(2.1%)分析未评估关注病灶。
  • 160例(56.3%)患者CT-FFR大于0.80。

诊断标准与关键数值

  • CT-FFR大于0.80为本文报告的CT-FFR分析结果分类阈值。
  • 显著狭窄患者中,行CT-FFR分析者ICA率为25.5%,未行CT-FFR分析者为74.5%(P=0.04)。
  • 显著狭窄患者中,行CT-FFR分析者PCI率为21.1%,未行CT-FFR分析者为78.9%(P=0.05)。

临床应用与阅片要点

  • 在无心率控制条件下采用双源冠状动脉CTA于收缩晚期至舒张早期采集,可对临床指征患者实施CT-FFR分析。
  • CT-FFR分析由判读医师酌情决定,本研究中292例(9.7%)转诊行CT-FFR分析。
  • 作者认为在显著狭窄且平均心率65次/分的患者中,CT-FFR可能降低ICA和PCI率且不损害安全性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose This special report outlines a retrospective observational study of CT fractional flow reserve (CT-FFR) analysis using dual-source coronary CT angiography (CTA) scans performed without heart rate control and its impact on clinical outcomes. Materials and Methods All patients who underwent clinically indicated coronary CTA between August 2020 and August 2021 were included in this retrospective observational study. Scans were performed in the late systolic to early diastolic period without heart rate control and analyzed at the interpreting physician's discretion. Demographics, coronary CTA features, and rates of invasive coronary angiography (ICA), percutaneous coronary intervention (PCI), myocardial infarction, and all-cause death at 3 months were assessed by chart review. Results During the study period, 3098 patients underwent coronary CTA, of whom 113 with coronary bypass grafting were excluded. Of the remaining 2985 patients, 292 (9.7%) were referred for CT-FFR analysis. Two studies (0.7%) were rejected from CT-FFR analysis, and six (2.1%) analyses did not evaluate the lesion of concern. A total of 160 patients (56.3%) had CT-FFR greater than 0.80. Among patients with significant stenosis at coronary CTA, patients who underwent CT-FFR analysis presented with lower rates of ICA (74.5% vs 25.5%, P = .04) and PCI (78.9% vs 21.1%, P = .05). Conclusion CT-FFR was implemented in patients not requiring heart rate control by using dual-source coronary CTA acquisition and showed the potential to decrease rates of ICA and PCI without compromising safety in patients with significant stenosis and an average heart rate of 65 beats per minute. Keywords: Angiography, CT, CT-Angiography, Fractional Flow Reserve, Cardiac, Heart, Arteriosclerosis Supplemental material is available for this article. © RSNA, 2024.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Randhawa MK, Takigami AK, Thondapu V, et al. Selective Use of CT Fractional Flow at a Large Academic Medical Center: Insights from Clinical Implementation after 1 Year of Practice. Radiol Cardiothorac Imaging. 2024. PMID: 38573127. doi:10.1148/ryct.230073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。