应用心血管磁共振特征追踪技术定量特发性炎性肌病患者的左心房应变
纳入36例特发性炎性肌病(IIM)患者和42例健康对照,用电影心脏磁共振和半自动技术测量左心房应变及应变率。IIM患者左心室质量指数有显著差异,左心房总应变(εs,p4=0.046)和被动应变(εe,p4=0.002)与对照有显著差异;εe与左心室射血分数相关性最强(r=0.581,p<0.01)。结论认为IIM患者左心房储器功能和管道功能改变,左心房应变可反映左心房功能。
要点
- IIM患者左心房总应变(εs,p4=0.046)和被动应变(εe,p4=0.002)较健康对照显著减低。
- εe与左心室射血分数相关性最强(r=0.581,p<0.01)。
- IIM患者与对照的左/右心室常规功能无显著差异(p>0.05)。
核心结论
- IIM患者存在左心房储器功能和管道功能改变,左心房应变可反映左心房功能。
研究设计与样本
- 研究纳入36例IIM患者和42例健康对照,共78例参与者。
- 采用电影心脏磁共振成像及本院半自动技术测量左心房应变发生和应变率。
- 定量分析左心房整体功能指标,包括储器功能、管道功能和助力泵功能。
关键影像表现/征象
- IIM患者与健康对照的左/右心室常规功能无显著差异(p>0.05)。
- 高hs-cTnI患者与正常hs-cTnI患者之间左/右心室常规功能亦无显著差异(p>0.05)。
- 左心室质量指数在IIM患者与对照之间(p1=0.003)以及高hs-cTnI与正常hs-cTnI患者之间(p2<0.01)均有显著差异。
诊断标准与关键数值
- IIM患者与对照比较,仅左心房总应变(εs)有显著差异(p4=0.046)。
- IIM患者与对照比较,仅左心房被动应变(εe)有显著差异(p4=0.002)。
- 高hs-cTnI患者与正常hs-cTnI患者比较,εs有差异(p3=0.012)。
- 高hs-cTnI患者与正常hs-cTnI患者比较,εe有差异(p4=0.047)。
- εe与左心室射血分数相关性最强(r=0.581,p<0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Left atrial (LA) dysfunction is involved in idiopathic inflammatory myopathy (IIM). Multiparametric cardiovascular magnetic resonance (CMR) strain imaging is a feasible and reproducible tool for examining global and regional LA functions, as well as left ventricular (LV) function in IIM patients.
AIM: The aim of this study was to evaluate the feasibility and reproducibility of LA strain occurrence and strain rate for LA function assessment using CMR in IIM cases.
MATERIALS AND METHODS: A total of 36 IIM and 42 healthy control cases were included. Baseline ventricular function was comparatively assessed in both groups. LA strain occurrence and strain rate were examined by cine cardiac magnetic resonance imaging [MRI] utilizing an in-house semiautomated technique. LA global function indexes were quantitated, including reservoir, conduit, and booster-pump functions.
RESULTS: A total of 78 participants were enrolled in this study. There was no significant difference in left/right ventricular routine functions between IIM patients and control individuals (p>0.05); the same results (p>0.05) was also observed between patients with high hs-cTnI and normal. However, LV mass index had significant difference (p1=0.003, p2<0.01). Compared with IIM patients and control individuals, only total strain (εs) (p4=0.046) and passive strain (εe) (p4=0.002) showed significant difference, and in cases with high hs-cTnI and normal hs-cTnI, there are differences for εs (p3=0.012) and εe (p4=0.047). The strongest association was found between εe and LV ejection fraction (LVEF) (r=0.581, p<0.01).
CONCLUSION: IIM cases have altered LA reservoir and conduit functions, and LA strain could reflect LA function.
引用
- Yu LZ, Lin YW, Shi RY, et al. Quantification of left atrial strain in patients with idiopathic inflammatory myopathy using cardiovascular magnetic resonance feature tracking. Clin Radiol. 2024. PMID: 38599951. doi:10.1016/j.crad.2024.03.005