文献速递妇产影像儿科影像心血管US

母体高氧在预测胎儿右型大动脉转位出生后是否需要球囊房间隔造口术中的作用

Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d-transposition of the great arteries.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-01-01

该回顾性单中心研究纳入41例胎儿右型大动脉转位,于孕33-38周行母体高氧试验,评估卵圆孔大小及动脉导管分流方向。母体高氧下二维测量的卵圆孔≤3.2 mm预测急诊球囊房间隔造口术的敏感度为93%、特异度为78%。作者提出在计划分娩时纳入孕晚期母体高氧试验,但认为仍需进一步研究。

要点

  • 母体高氧下二维卵圆孔≤3.2 mm预测急诊球囊房间隔造口术敏感度93%、特异度78%。
  • 母体高氧下二维卵圆孔中位数在急诊球囊房间隔造口术组为2.5 mm,低于未行球囊房间隔造口术组的4.1 mm。
  • 作者提出在计划右型大动脉转位胎儿分娩时纳入孕晚期母体高氧试验。

核心结论

  • 在右型大动脉转位胎儿中,母体高氧下测量卵圆孔大小及动脉导管分流方向可提高预测出生后是否需要球囊房间隔造口术的能力,但作者认为仍需进一步研究。

研究设计与样本

  • 回顾性单中心研究,纳入2017年1月1日至2020年3月30日在费城儿童医院于孕33-38周行母体高氧试验的41例右型大动脉转位胎儿;所有胎儿室间隔完整或室间隔缺损小于3 mm。

关键影像表现/征象

  • 母体高氧下二维测量的卵圆孔中位数在急诊球囊房间隔造口术组为2.5 mm(四分位距2.0-3.0 mm),在未行球囊房间隔造口术组为4.1 mm(四分位距3.4-5.0 mm),P < 0.001。

诊断标准与关键数值

  • 母体高氧下二维卵圆孔≤3.2 mm预测需要急诊球囊房间隔造口术的敏感度为93%(95%CI 66-100%),特异度为78%(95%CI 58-91%)。
  • 单变量分析中,室内空气下及母体高氧下测量的卵圆孔大小、母体高氧下动脉导管前向分流均预测球囊房间隔造口术。

临床应用与阅片要点

  • 作者提出在计划右型大动脉转位胎儿分娩时纳入孕晚期母体高氧试验。

局限性

  • 作者指出仍需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Predicting whether postnatal balloon atrial septostomy (BAS) will be necessary for fetuses with dextro-transposition of the great arteries (d-TGA) remains challenging. We sought to determine whether fetal echocardiographic measurements obtained during maternal hyperoxygenation (MH) can improve our ability to predict the need for postnatal BAS.

METHODS: This was a retrospective, single-institution review of d-TGA fetuses whose mothers had undergone MH at 33-38 weeks' gestation at the Children's Hospital of Philadelphia, between 1 January 2017 and 30 March 2020. All fetal d-TGA cases had either an intact ventricular septum or small ventricular septal defect measuring < 3 mm. Patent foramen ovale (PFO) size, measured by two-dimensional imaging (2D) and by color Doppler, and patent ductus arteriosus (PDA) shunting (antegrade vs bidirectional) were assessed in room air (RA) and during MH. BAS status and timing were recorded.

RESULTS: Of 41 fetal d-TGA cases in the cohort, 23 underwent postnatal BAS, while 18 did not, and 14 subjects underwent emergent BAS within 3 h of delivery. On univariate analysis, PFO size measured both in RA and during MH and antegrade shunting in the PDA during MH predicted BAS. During MH, median PFO size by 2D was significantly smaller in fetuses which underwent emergent BAS compared to fetuses which did not undergo BAS (2.5 (interquartile range (IQR), 2.0-3.0) mm vs 4.1 (IQR, 3.4-5.0) mm; P < 0.001). On cut-point analysis, PFO size by 2D during MH of ≤ 3.2 mm predicted the need for emergent BAS with a sensitivity of 93% (95% CI, 66-100%) and a specificity of 78% (95% CI, 58-91%).

CONCLUSIONS: In fetuses with d-TGA, measurement of PFO size and direction of PDA shunting during MH improves our ability to predict the need for postnatal BAS, although additional study is needed. We propose incorporating third-trimester MH when planning delivery of a d-TGA fetus. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Szwast A, Penney C, Sharma P, et al. Role of maternal hyperoxygenation in predicting need for postnatal balloon atrial septostomy in fetal d-transposition of the great arteries. Ultrasound Obstet Gynecol. 2024. PMID: 38642340. doi:10.1002/uog.27664

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。