文献速递心血管CT

超高清光子计数探测器CT改善冠状动脉支架可视化

Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT.
PubMed 文献 · Eur Radiol · 2024-04-27

本研究纳入69例患者131枚冠状动脉支架,比较标准分辨率与超高清光子计数探测器CT冠状动脉CT血管成像的图像质量和诊断性能。超高清图像支架内管腔直径显著大于标准分辨率,其中Bv72重建核主观图像质量最佳;在12例患者25枚支架中,标准分辨率与超高清Bv72的诊断准确率分别为78.3%和88.0%。

要点

  • 超高清光子计数探测器CT可显著改善冠状动脉支架可视化并减少开花伪影。
  • Bv72重建核在显示支架 struts 和支架内管腔方面主观评分最佳。
  • 超高清Bv72诊断准确率88.0%,高于标准分辨率的78.3%。

核心结论

  • 光子计数探测器CT的超高清冠状动脉CT血管成像可显著改善冠状动脉支架的可视化和诊断性能,Bv72为显示支架 struts 和支架内管腔的最佳重建核。

研究设计与样本

  • 研究纳入2023年7月至2023年9月接受冠状动脉支架置入术后行双源光子计数探测器CT冠状动脉CT血管成像的患者,共69例(年龄68.0 [61.0, 73.0]岁,男性46例)131枚支架;标准分辨率图像层厚/间距0.6/0.4 mm采用血管核Bv48重建,超高清图像层厚/间距0.2/0.2 mm采用6种锐度水平的血管核(Bv48、Bv56、Bv60、Bv64、Bv72和Bv76)重建;12例患者25枚支架行有创冠状动脉造影。

关键影像表现/征象

  • 所有超高清图像的支架内管腔直径均显著大于标准分辨率图像(p < 0.001)。
  • 超高清Bv72和Bv76的支架内管腔直径分别为2.17 [1.93, 2.63] mm和2.20 [1.93, 2.59] mm,为排名前两位的重建核。
  • 主观分析显示超高清Bv72图像在减少开花伪影、显示支架内管腔和支架以及诊断信心方面效果最显著(p < 0.001)。

诊断标准与关键数值

  • 标准分辨率图像诊断准确率为78.3%(95%CI:56.3%-92.5%)。
  • 超高清Bv72图像诊断准确率为88.0%(95%CI:68.8%-97.5%)。

临床应用与阅片要点

  • 采用光子计数探测器CT行冠状动脉CT血管成像时,超高清重建可改善支架内管腔显示并减少开花伪影。
  • Bv72重建核在支架 struts 和支架内管腔显示方面主观评分最佳,可作为支架成像的优选重建核。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to compare the image quality and diagnostic performance of standard-resolution (SR) and ultra-high-resolution (UHR) coronary CT angiography (CCTA) based on photon-counting detector CT (PCD-CT) of coronary stents and explore the best reconstruction kernel for stent imaging.

METHODS: From July 2023 to September 2023, patients were enrolled to undergo CCTA using a dual-source PCD-CT system after coronary angioplasty with stent placement. SR images with a slice thickness/increment of 0.6/0.4 mm were reconstructed using a vascular kernel (Bv48), while UHR images with a slice thickness/increment of 0.2/0.2 mm were reconstructed using vascular kernels of six sharpness levels (Bv48, Bv56, Bv60, Bv64, Bv72, and Bv76). The in-stent lumen diameters were evaluated. Subjective image quality was also evaluated by a 5-point Likert scale. Invasive coronary angiography was conducted in 12 patients (25 stents).

RESULTS: Sixty-nine patients (68.0 [61.0, 73.0] years, 46 males) with 131 stents were included. All UHR images had significantly larger in-stent lumen diameter than SR images (p < 0.001). Specifically, UHR-Bv72 and UHR-Bv76 for in-stent lumen diameter (2.17 [1.93, 2.63] mm versus 2.20 [1.93, 2.59] mm) ranked the two best kernels. The subjective analysis demonstrated that UHR-Bv72 images had the most pronounced effect on reducing blooming artifacts, showcasing in-stent lumen and stent demonstration, and diagnostic confidence (p < 0.001). Furthermore, SR and UHR-Bv72 images showed a diagnostic accuracy of 78.3% (95% confidence interval [CI]: 56.3%-92.5%) and 88.0% (95%CI: 68.8%-97.5%), respectively.

CONCLUSION: UHR CCTA by PCD-CT leads to significantly improved visualization and diagnostic performance of coronary stents, and Bv72 is the optimal reconstruction kernel showing the stent struts and in-stent lumen.

CLINICAL RELEVANCE STATEMENT: The significantly improved visualization of coronary stents using ultra-high resolution CCTA could increase the diagnostic accuracy for in-stent restenosis and avoid unnecessary invasive quantitative coronary angiography, thus changing the clinical management for patients after percutaneous coronary intervention.

KEY POINTS: Coronary stent imaging is challenging with energy-integrating detector CT due to "blooming artifacts." UHR images using a PCD-CT enhanced coronary stent visualization. UHR coronary stent imaging demonstrated improved diagnostic accuracy in clinical settings.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Qin L, Zhou S, Dong H, et al. Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT. Eur Radiol. 2024. PMID: 38676731. doi:10.1007/s00330-024-10760-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。