文献速递胸部CT

能谱CT定量参数对鉴别结核相关纤维化纵隔炎与腔内型肺癌的附加价值:初步结果

Added value of spectral computed tomography quantitative parameters for differentiating tuberculosis-associated fibrosing mediastinitis from endobronchial lung cancer: initial results.
PubMed 文献 · Clin Radiol · 2024-03-15

回顾性分析109例肺不张患者的胸部能谱CT增强图像,分为结核相关纤维化纵隔炎组77例与腔内型肺癌组32例,以支气管镜和/或病理为参考标准。能谱模型鉴别两病的AUC为0.965,优于常规模型的0.916(P=0.038)。

要点

  • 能谱模型鉴别结核相关纤维化纵隔炎与腔内型肺癌的AUC为0.965,高于常规模型的0.916(P=0.038)。
  • 能谱参数与常规参数呈中等相关,如淋巴结碘浓度归一化AEF与常规CT AEF的r=0.604。
  • 常规CT特征联合能谱参数可进一步提高鉴别两种导致肺不张病变的能力。

核心结论

  • 能谱参数与常规参数呈中等相关,常规CT特征联合能谱参数可进一步提高鉴别结核相关纤维化纵隔炎与腔内型肺癌的能力。

研究设计与样本

  • 回顾性分析109例肺不张患者的胸部能谱CT增强图像,其中结核相关纤维化纵隔炎组77例、腔内型肺癌组32例。
  • 分组依据为支气管镜和/或病理结果,采用最小绝对收缩和选择算子回归优化能谱参数选择。
  • 以Pearson相关分析能谱参数与常规参数的关系,多变量逻辑回归构建能谱模型,将能谱模型中的参数替换为相应常规参数构建常规模型,并以受试者工作特征曲线分析评价诊断效能。

诊断标准与关键数值

  • 能谱模型鉴别结核相关纤维化纵隔炎与腔内型肺癌的AUC为0.965。
  • 常规模型鉴别两种病变的AUC为0.916。
  • 能谱模型与常规模型AUC比较P=0.038。
  • ㏒(L-AEFNIC)-㏒(L-AEFC)的相关系数r=0.419(P<0.0001),㏒(O-AEF40KeV)-㏒(O-AEFC)的r=0.475(P<0.0001),[L-A-HAP(I)]-(L-U-CT)的r=0.604(P<0.0001)。

临床应用与阅片要点

  • 对表现为肺不张的患者,可在常规CT特征基础上联合能谱CT定量参数(如淋巴结碘浓度归一化AEF、支气管梗阻区40KeV AEF、淋巴结动脉期羟基磷灰石碘浓度等)辅助鉴别结核相关纤维化纵隔炎与腔内型肺癌。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to explore the added value of spectral computed tomography (CT) parameters to conventional CT features for differentiating tuberculosis-associated fibrosing mediastinitis (TB-associated FM) from endobronchial lung cancer (EBLC).

METHODS: Chest spectral CT enhancement images from 109 patients with atelectasis were analyzed retrospectively. These patients were divided into two distinct categories: the TB-associated FM group (n = 77) and the EBLC group (n = 32), based on bronchoscopy and/or pathological findings. The selection of spectrum parameters was optimized with the least absolute shrinkage and selection operator regression analysis. The relationship between the spectrum parameters and conventional parameters was explored using Pearson's correlation. Multivariate logistic regression analysis was used to build spectrum model. The spectrum parameters in the spectrum model were replaced with their corresponding conventional parameters to build the conventional model. Diagnostic performances were evaluated using receiver operating characteristic curve analyses.

RESULTS: There was a moderate correlation between the parameters ㏒(L-AEFNIC) - ㏒(L-AEFC) (r= 0.419; p< 0.0001), ㏒(O-AEF40KeV) - ㏒(O-AEFC) (r= 0.475; p< 0.0001), [L-A-hydroxyapatite {HAP}(I)] - (L-U-CT) (r= 0.604; p< 0.0001), {arterial enhancement fraction (AEF) derived from normalized iodine concentration (NIC) of lymph node (L-AEFNIC), AEF derived from CT40KeV of bronchial obstruction (O-AEF40KeV), arterial-phase Hydroxyapatite (Iodine) concentration of lymph node [L-A-HAP(I)], AEF derived from conventional CT (AEFC), unenhanced CT value (U-CT)}. Spectrum model could improve diagnostic performances compared to conventional model (area under curve: 0.965 vs 0.916, p= 0.038).

CONCLUSION: There was a moderate correlation between spectrum parameters and conventional parameters. Integrating conventional CT features with spectrum parameters could further improve the ability in differentiating TB-associated FM from EBLC.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Yang J, Deng L, Jing M, et al. Added value of spectral computed tomography quantitative parameters for differentiating tuberculosis-associated fibrosing mediastinitis from endobronchial lung cancer: initial results. Clin Radiol. 2024. PMID: 38658213. doi:10.1016/j.crad.2024.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。