MRI检测肺结节的诊断效能:系统综述与Meta分析
该系统综述与Meta分析纳入10项研究(1354例患者、2062个CT检出结节),以CT为参考标准评估MRI对≥4 mm肺结节的诊断效能;MRI总体病灶敏感度为87.7%(95%CI:81.1,92.2),假阳性结节率(FPP)为12.4%(95%CI:7.0,21.1);对≥8-10 mm结节敏感度达98.5%(95%CI:90.4,99.8),对<8 mm结节为80.5%(95%CI:71.5,87.1),结论认为MRI对≥4 mm肺结节总体表现良好,对≥8-10 mm结节效能几乎等同于CT且FPP低。
要点
- MRI对≥4 mm肺结节的病灶敏感度为87.7%(95%CI:81.1,92.2),假阳性结节率(FPP)为12.4%(95%CI:7.0,21.1)。
- 按大小分层:≥8-10 mm结节敏感度98.5%(95%CI:90.4,99.8),<8 mm结节敏感度80.5%(95%CI:71.5,87.1)。
- 结论认为MRI对≥8-10 mm结节效能几乎等同于CT,对<8 mm结节敏感度较低。
核心结论
- MRI对≥4 mm肺结节总体诊断效能良好,对≥8-10 mm结节效能几乎等同于CT且假阳性结节率低。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase、Scopus等数据库2000年1月至2023年3月发表的文献,方案注册于PROSPERO(CRD42023437509)。
- 纳入10项研究,共1354例患者、2062个CT检出结节,以CT为参考标准评估MRI对≥4 mm肺结节的诊断效能。
- 排除纳入微结节、未按大小分层或无法提取列联表数据的研究。
- 主要结局为MRI的病灶敏感度和每例患者假阳性结节率(FPP),并进行按大小分层的亚组分析和其他协变量的Meta回归。
诊断标准与关键数值
- MRI对≥4 mm肺结节的病灶敏感度为87.7%(95%CI:81.1,92.2),假阳性结节率(FPP)为12.4%(95%CI:7.0,21.1)。
- MRI对≥8-10 mm结节的敏感度为98.5%(95%CI:90.4,99.8)。
- MRI对<8 mm结节的敏感度为80.5%(95%CI:71.5,87.1)。
临床应用与阅片要点
- 原文结论认为MRI对≥4 mm肺结节检测总体表现良好,对≥8-10 mm结节效能几乎等同于CT且假阳性结节率低。
- 阅片时需注意MRI对<8 mm结节的敏感度(80.5%)低于≥8-10 mm结节(98.5%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To perform a meta-analysis of the diagnostic performance of MRI for the detection of pulmonary nodules, with use of CT as the reference standard. Materials and Methods PubMed, Embase, Scopus, and other databases were systematically searched for studies published from January 2000 to March 2023 evaluating the performance of MRI for diagnosis of lung nodules measuring 4 mm or larger, with CT as reference. Studies including micronodules, nodules without size stratification, or those from which data for contingency tables could not be extracted were excluded. Primary outcomes were the per-lesion sensitivity of MRI and the rate of false-positive nodules per patient (FPP). Subgroup analysis by size and meta-regression with other covariates were performed. The study protocol was registered in the International Prospective Register of Systematic Reviews, or PROSPERO (no. CRD42023437509). Results Ten studies met inclusion criteria (1354 patients and 2062 CT-detected nodules). Overall, per-lesion sensitivity of MRI for nodules measuring 4 mm or larger was 87.7% (95% CI: 81.1, 92.2), while the FPP rate was 12.4% (95% CI: 7.0, 21.1). Subgroup analyses demonstrated that MRI sensitivity was 98.5% (95% CI: 90.4, 99.8) for nodules measuring at least 8-10 mm and 80.5% (95% CI: 71.5, 87.1) for nodules less than 8 mm. Conclusion MRI demonstrated a good overall performance for detection of pulmonary nodules measuring 4 mm or larger and almost equal performance to CT for nodules measuring at least 8-10 mm, with a low rate of FPP. Systematic review registry no. CRD42023437509 Keywords: Lung Nodule, Lung Cancer, Lung Cancer Screening, MRI, CT Supplemental material is available for this article. © RSNA, 2024.
引用
- Cavion CC, Altmayer S, Forte GC, et al. Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis. Radiol Cardiothorac Imaging. 2024. PMID: 38634743. doi:10.1148/ryct.230241
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。