急性肺栓塞的诊断:当光子计数探测器CT在日常工作中取代能量积分探测器CT

Diagnosis of acute pulmonary embolism: when photon-counting-detector CT replaces energy-integrating-detector CT in daily routine.
PubMed 文献 · Eur Radiol · 2024-04-18

本研究比较光子计数探测器CT(PCD-CT)与能量积分探测器CT(EID-CT)诊断急性肺栓塞的表现。PCD-CT组全部患者均可获得光谱成像,采集时间更短(0.9±0.1秒 vs 4.0±0.3秒,p<0.001),CTDIvol和DLP分别降低46.3%和47.7%,辐射剂量降低约48%,形态学和灌注成像对所有患者可用。

要点

  • PCD-CT使全部患者获得光谱成像(形态学+肺灌注),而EID-CT仅66.5%患者可用。
  • PCD-CT平均采集时间0.9±0.1秒,显著短于EID-CT的4.0±0.3秒(p<0.001)。
  • PCD-CT辐射剂量较EID-CT降低约48%(CTDIvol降46.3%,DLP降47.7%)。

核心结论

  • 与EID-CT相比,PCD-CT扫描的所有患者均可获得形态学和灌注成像,辐射剂量降低48%。

研究设计与样本

  • 两组队列分别接受EID-CT(组1,n=158)和PCD-CT(组2,n=172)CT血管造影检查;组1含双能(组1a)或单能(组1b)两种选项,组2仅单源光谱成像一种选项。

诊断标准与关键数值

  • 可诊断检查比例:组1a为95.2%(100/105),组1b为100%(53/53),组2为95.3%(164/172)。
  • 非诊断检查比例:组1a为4.8%(5/105),组2为4.7%(8/172),主要因血管充盈质量欠佳,低能图像可恢复诊断质量。
  • 70 keV(组2)与平均图像(组1a)比较:肺动脉平均衰减无差异(p=0.13);组2图像噪声显著更高(p<0.001),主观图像噪声无差异(p=0.29);无伪影检查比例组2为89%,组1a为28.6%。

临床应用与阅片要点

  • PCD-CT可在不增加辐射剂量的前提下为全部患者提供形态学图像和肺灌注光谱成像。
  • PCD-CT采集时间更短(0.9±0.1秒 vs 4.0±0.3秒),有助于减少运动伪影。
  • PCD-CT无伪影检查比例更高(89% vs 28.6%),但客观图像噪声更高而主观噪声无差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the diagnostic approach of acute pulmonary embolism (PE) with photon-counting-detector CT (PCD-CT) and energy-integrating-detector CT (EID-CT).

MATERIALS AND METHODS: Two cohorts underwent CT angiographic examinations with EID-CT (Group 1; n = 158) and PCD-CT (Group 2; n = 172), (b) with two options in Group 1, dual energy (Group 1a) or single energy (Group 1b) and a single option in Group 2 (spectral imaging with single source).

RESULTS: In Group 2, all patients benefited from spectral imaging, only accessible to 105 patients (66.5%) in Group 1, with a mean acquisition time significantly shorter (0.9 ± 0.1 s vs 4.0 ± 0 .3 s; p < 0.001) and mean values of CTDIvol and DLP reduced by 46.3% and 47.7%, respectively. Comparing the quality of 70 keV (Group 2) and averaged (Group 1a) images: (a) the mean attenuation within pulmonary arteries did not differ (p = 0.13); (b) the image noise was significantly higher (p < 0.001) in Group 2 with no difference in subjective image noise (p = 0.29); and (c) 89% of examinations were devoid of artifacts in Group 2 vs 28.6% in Group 1a. The percentage of diagnostic examinations was 95.2% (100/105; Group 1a), 100% (53/53; Group 1b), and 95.3% (164/172; Group 2). There were 4.8% (5/105; Group 1a) and 4.7% (8/172; Group 2) of non-diagnostic examinations, mainly due to the suboptimal quality of vascular opacification with the restoration of a diagnostic image quality on low-energy images.

CONCLUSION: Compared to EID-CT, morphology and perfusion imaging were available in all patients scanned with PCD-CT, with the radiation dose reduced by 48%.

CLINICAL RELEVANCE STATEMENT: PCD-CT enables scanning patients with the advantages of both spectral imaging, including high-quality morphologic imaging and lung perfusion for all patients, and fast scanning-a combination that is not simultaneously accessible with EID-CT while reducing the radiation dose by almost 50%.

来源:Eur Radiol,查看原文。版权归原作者所有。