文献速递头颈神经MR

比较双回波稳态水激发序列与稳态自由进动序列在腮腺肿瘤患者面神经及肿瘤定位中的价值

Comparing the Double-Echo Steady-State with Water Excitation and Constructive Interference in Steady-State Sequence Techniques for Identifying Extracranial Facial Nerve and Tumor Positions in Patients with Parotid Tumors.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-09-09

回顾性纳入16名健康志愿者(32条面神经)和25例腮腺肿瘤患者(25条面神经),比较DESS-WE与CISS序列的颅外面神经图像质量及肿瘤定位诊断效能。CISS在面神经分支显示和肿瘤-面神经空间关系上图像质量评分显著高于DESS-WE(均P<.001),肿瘤定位AUC为CISS 0.981 vs DESS-WE 0.942(P=.1489),两者诊断效能相当。

要点

  • CISS在颞面干与颈面干区分、面神经与肿瘤空间关系显示上评分显著高于DESS-WE(均P<.001)。
  • 腮腺肿瘤定位诊断效能两者相当,AUC为CISS 0.981 vs DESS-WE 0.942(P=.1489)。
  • 3T MR联合64通道头颈线圈行非增强颅外面神经成像,CISS可获得更可靠的面神经形态显示。

核心结论

  • CISS在腮腺肿瘤定位方面达到与DESS-WE相当的诊断效能,并具有更好的图像质量和更可靠的面神经形态学显示。

研究设计与样本

  • 回顾性研究,纳入16名健康志愿者共32条面神经和25例腮腺肿瘤患者共25条面神经,使用3T MR扫描仪和64通道头颈线圈行非增强颅外面神经MR成像,采用DESS-WE与CISS序列,由2名放射科医师以5分Likert量表主观评价图像质量,并以Cohen κ系数评估观察者间和观察者内一致性,采用受试者工作特征分析计算肿瘤定位诊断效能。

诊断标准与关键数值

  • 图像质量采用5分Likert量表主观评价;健康志愿者中CISS对颞面干和颈面干的区分评分显著高于DESS-WE(均P<.001);腮腺肿瘤患者中CISS在显示面神经与肿瘤空间关系及诊断信心方面优于DESS-WE(均P<.001);腮腺肿瘤定位的AUC为CISS 0.981 vs DESS-WE 0.942(P=.1489)。

临床应用与阅片要点

  • 原文结论为CISS在腮腺肿瘤定位方面达到与DESS-WE相当的诊断效能,并具有更好的图像质量和更可靠的面神经形态学显示。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Reliable preoperative visualization of facial nerve morphology and understanding the spatial relationship between the facial nerve and tumors in the parotid gland can help clinicians perform safe and effective surgeries. Hence, this study aimed to compare the image quality of extracranial facial nerves obtained by using double-echo steady state with water excitation (DESS-WE) and CISS sequences and evaluate their diagnostic efficacy in the localization of parotid tumors.

MATERIALS AND METHODS: In total, 32 facial nerves of 16 healthy volunteers and 25 facial nerves of 25 patients with parotid tumors were included in this retrospective study. All participants underwent noncontrast-enhanced extracranial facial nerve MR imaging with DESS-WE and CISS with a 3T MR scanner equipped with a 64-channel head and neck coil. Image quality was subjectively evaluated by using a 5-point Likert scale by 2 radiologists. Inter- and intrarater agreements were assessed by using the Cohen κ coefficient. Receiver operating characteristic analysis was performed, and the diagnostic efficacies of DESS-WE and CISS images in localizing parotid tumors were calculated.

RESULTS: For healthy volunteers (11 men and 5 women; median age, 26 years), image quality scores for CISS were significantly higher than those for DESS-WE for the discrimination of the temporofacial and cervicofacial trunks (both, P < .001). In patients with parotid tumors (12 men and 13 women; median age, 58 years), CISS performed better than DESS-WE in terms of visualizing the spatial relationship of the facial nerve to the tumor and diagnostic confidence (both, P < .001). Regarding the localization of parotid tumors, CISS showed excellent performance, comparable to that of DESS-WE (area under the curve, 0.981 versus 0.942, P = .1489).

CONCLUSIONS: CISS achieved diagnostic performance comparable to DESS-WE in parotid tumor localization, with favorable image quality and more reliable morphologic visualization of the facial nerve.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Fan X, Ding C, Zhao G, et al. Comparing the Double-Echo Steady-State with Water Excitation and Constructive Interference in Steady-State Sequence Techniques for Identifying Extracranial Facial Nerve and Tumor Positions in Patients with Parotid Tumors. AJNR Am J Neuroradiol. 2024. PMID: 38637024. doi:10.3174/ajnr.A8309

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。