迈向精准诊断:多参数3T MRI机器学习鉴别眼眶恶性肿瘤
单中心前瞻性研究纳入113例眼眶肿块患者,术前行3T MRI多参数成像(DCE、DWI、IVIM及形态学),用随机森林重复嵌套交叉验证评估8种特征组合。综合全部46个特征的模型预测恶性AUC为0.9[0.73-0.99],精简10特征模型AUC为0.88[0.71-0.99],作者认为精简模型更适于临床应用。
要点
- 综合46个特征(形态学、DWI、DCE、IVIM)的随机森林模型预测眼眶肿瘤恶性AUC为0.9[0.73-0.99]。
- 精简10特征模型AUC为0.88[0.71-0.99],性能接近综合模型。
- SHAP分析显示最重要10个特征包括3个定量IVIM、4个定量DCE、1个定量DWI、1个定性DWI特征及年龄。
核心结论
- 整合DCE、DWI、IVIM及形态学多参数MRI的机器学习模型能高效鉴别眼眶肿瘤良恶性,精简10特征模型性能接近综合模型,可能更适合临床应用。
研究设计与样本
- 单中心前瞻性研究,2015年12月至2021年5月纳入113例眼眶肿块患者,术前行3T MRI多参数成像(DCE、DWI、IVIM及形态学),采用随机森林分类器重复嵌套交叉验证评估8种特征组合。
诊断标准与关键数值
- 综合全部46个特征(形态学、DWI、DCE、IVIM)模型预测恶性AUC为0.9[0.73-0.99];精简10特征模型AUC为0.88[0.71-0.99]。
临床应用与阅片要点
- 作者认为精简10特征模型性能接近综合模型,可能更适合临床应用。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Orbital tumors present a diagnostic challenge due to their varied locations and histopathological differences. Although recent advancements in imaging have improved diagnosis, classification remains a challenge. The integration of artificial intelligence in radiology and ophthalmology has demonstrated promising outcomes.
PURPOSE: This study aimed to evaluate the performance of machine learning models in accurately distinguishing malignant orbital tumors from benign ones using multiparametric 3 T magnetic resonance imaging (MRI) data.
MATERIALS AND METHODS: In this single-center prospective study, patients with orbital masses underwent presurgery 3 T MRI scans between December 2015 and May 2021. The MRI protocol comprised multiparametric imaging including dynamic contrast-enhanced (DCE), diffusion-weighted imaging (DWI), intravoxel incoherent motion (IVIM), as well as morphological imaging acquisitions. A repeated nested cross-validation strategy using random forest classifiers was used for model training and evaluation, considering 8 combinations of explanatory features. Shapley additive explanations (SHAP) values were used to assess feature contributions, and the model performance was evaluated using multiple metrics.
RESULTS: One hundred thirteen patients were analyzed (57/113 [50.4%] were women; average age was 51.5 ± 17.5 years, range: 19-88 years). Among the 8 combinations of explanatory features assessed, the performance on predicting malignancy when using the most comprehensive model, which is the most exhaustive one incorporating all 46 explanatory features-including morphology, DWI, DCE, and IVIM, achieved an area under the curve of 0.9 [0.73-0.99]. When using the streamlined "10-feature signature" model, performance reached an area under the curve of 0.88 [0.71-0.99]. Random forest feature importance graphs measured by the mean of SHAP values pinpointed the 10 most impactful features, which comprised 3 quantitative IVIM features, 4 quantitative DCE features, 1 quantitative DWI feature, 1 qualitative DWI feature, and age.
CONCLUSIONS: Our findings demonstrate that a machine learning approach, integrating multiparametric MRI data such as DCE, DWI, IVIM, and morphological imaging, offers high-performing models for differentiating malignant from benign orbital tumors. The streamlined 10-feature signature, with a performance close to the comprehensive model, may be more suitable for clinical application.
引用
- O'Shaughnessy E, Senicourt L, Mambour N, et al. Toward Precision Diagnosis: Machine Learning in Identifying Malignant Orbital Tumors With Multiparametric 3 T MRI. Invest Radiol. 2024. PMID: 38597586. doi:10.1097/RLI.0000000000001076
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。