文献速递神经外周血管MR

人工智能约束压缩SENSE加速三维各向同性T1 VISTA序列用于血管壁MR成像的可行性:探索相比传统压缩SENSE更高加速因子的潜力

Feasibility of Artificial Intelligence Constrained Compressed SENSE Accelerated 3D Isotropic T1 VISTA Sequence For Vessel Wall MR Imaging: Exploring the Potential of Higher Acceleration Factors Compared to Traditional Compressed SENSE.
PubMed 文献 · Acad Radiol · 2024-04-24

前瞻性纳入40例颅内或颈动脉粥样硬化斑块患者,在3.0 T MR上比较传统压缩SENSE与人工智能约束压缩SENSE重建的高分辨血管壁图像。CS-AI在加速因子至12时图像质量评分良好,CS-AI 10方案管腔图像最佳,斑块SNR和CNR均优于传统CS。研究表明CS-AI用于3D T1 VISTA血管壁成像可行,更高加速因子可行且可能用于临床。

要点

  • CS-AI在加速因子至12时图像质量评分与参考扫描相当,CS-AI 10方案正常及病变处管腔图像最佳。
  • 斑块SNR在CS-AI组显著高于CS组直至加速因子增至12,CS-AI各加速因子CNR均高于CS。
  • 增强前T1WI的CNR在CS-AI 10最高,增强后T1WI的CNR在CS-AI 12最高。

核心结论

  • CS-AI技术用于3D T1 VISTA序列诊断动脉粥样硬化性血管病可行,图像质量和诊断效率与传 统CS相当或更优,更高加速因子可行且有潜力用于血管壁MR成像。

研究设计与样本

  • 前瞻性研究,2022年10月1日至2023年10月31日纳入40例颅内或颈动脉粥样硬化斑块患者,在3.0 T MR系统上行高分辨血管壁成像,采用可变压缩SENSE加速因子并经优化的人工智能约束压缩SENSE重建,图像分别经传统CS和优化CS-AI重建,由两名放射科医师定性评分并定量评估SNR和CNR。

关键影像表现/征象

  • CS-AI组在加速因子至12时图像质量评分与参考扫描相比良好(P < 0.05)。
  • CS-AI 10方案在正常和病变部位管腔均提供最佳图像(P < 0.05)。
  • 斑块SNR在CS-AI组显著高于CS组直至加速因子增至12(P < 0.05)。
  • CS-AI方案在增强前和增强后T1WI上无论何种加速因子CNR均高于CS(P < 0.05)。

诊断标准与关键数值

  • CS-AI 10方案在增强前T1WI上CNR最高(P < 0.05)。
  • CS-AI 12方案在增强后T1WI上CNR最高(P < 0.05)。

临床应用与阅片要点

  • CS-AI技术可用于3D T1 VISTA血管壁MR成像,图像质量和诊断效率与传 统CS相当或更优。
  • 更高加速因子可行,CS-AI 10方案在增强前T1WI管腔和CNR表现最佳,CS-AI 12方案在增强后T1WI CNR最高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Investigate the feasibility of using deep learning-based accelerated 3D T1-weighted volumetric isotropic turbo spin-echo acquisition (VISTA) for vessel wall magnetic resonance imaging (VW-MRI), compared to traditional Compressed SENSE and optimize acceleration factor (AF) to obtain high-quality clinical images.

METHODS: 40 patients with atherosclerotic plaques in the intracranial or carotid artery were prospectively enrolled in our study from October 1, 2022 to October 31, 2023 underwent high-resolution vessel wall imaging on a 3.0 T MR system using variable Compressed SENSE (CS) AFs and reconstructed by an optimized artificial intelligence constrained Compressed SENSE (CS-AI). Images were reconstructed through both traditional CS and optimized CS-AI. Two radiologists qualitatively assessed the image quality scores of CS and CS-AI across different segments and quantitatively evaluated SNR (signal-to-noise ratio) and CNR (contrast-to-noise ratio) metrics. Paired t-tests, ANOVA, and Friedman tests analyzed image quality metrics. Written informed consent was obtained from all patients in this study.

RESULTS: CS-AI groups demonstrated good image quality scores compared to reference scans until AF up to 12 (P < 0.05). The CS-AI 10 protocol provided the best images in the lumen of both normal and lesion sites (P < 0.05). The plaque SNR was significantly higher in CS-AI groups compared to CS groups until the AF increased to 12 (P < 0.05). CS-AI protocols had higher CNR compared to CS with whichever AF on both pre-and post-contrast T1WI (P < 0.05), The CNR was highest in the CS-AI 10 protocol on pre-contrast T1WI and in CS-AI 12 on post-contrast T1WI (P < 0.05).

CONCLUSION: The study demonstrated the feasibility of using CS-AI technology to diagnose arteriosclerotic vascular disease with 3D T1 VISTA sequences. The image quality and diagnostic efficiency of CS-AI images were comparable or better than traditional CS images. Higher AFs are feasible and have potential for use in VW-MRI. The determination of standardized AFs for clinical scanning protocol is expected to help for empirical evaluation of new imaging technology.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ma Y, Wang M, Qiao Y, et al. Feasibility of Artificial Intelligence Constrained Compressed SENSE Accelerated 3D Isotropic T1 VISTA Sequence For Vessel Wall MR Imaging: Exploring the Potential of Higher Acceleration Factors Compared to Traditional Compressed SENSE. Acad Radiol. 2024. PMID: 38664146. doi:10.1016/j.acra.2024.03.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。