文献速递神经技术与安全MR

利用脑MRI脉搏波振幅估计脑血流量

Estimation of Cerebral Blood Flow Using the Pulse Wave Amplitude in Brain MRI.
PubMed 文献 · Acad Radiol · 2024-04-24

研究纳入24名20至61岁健康参与者,比较基于血流相关增强(FREE)脑MRI脉搏波振幅估计脑血流量(CBF)与伪连续动脉自旋标记(pCASL-MRI)的可行性,并回顾性评估加速潜力。结果显示FREE-MRI可粗略近似CBF,但与pCASL-MRI的概率分布存在差异,且在仅使用50%数据时近似CBF保持稳定。

要点

  • FREE-MRI估计的CBF在0至20 mL/100 g/min区间与pCASL-MRI直方图高度重叠。
  • pCASL-MRI在20至60 mL/100 g/min区间值更多,FREE-MRI在>60 mL/100 g/min区间高值更多。
  • FREE-MRI近似CBF在仅使用50%采集数据时保持稳定,使用40%数据时值较90%以上数据显著升高(P ≤ 0.05)。

核心结论

  • 所提出的技术相较于pCASL-MRI可对CBF进行粗略近似,需进一步序列优化以改善相对低灌注组织的测量,但为成像速度优化提供较大潜力,并可获得类似超声彩色多普勒模式的灌注加权图像。

研究设计与样本

  • 研究纳入24名20至61岁健康参与者进行脑MRI,灌注成像采用平衡稳态自由进动序列行FREE-MRI,并与pCASL-MRI比较;回顾性评估加速潜力。

关键影像表现/征象

  • 估计CBF值分布在0至20 mL/100 g/min区间直方图高度重叠。
  • pCASL-MRI在20至60 mL/100 g/min区间值更多,FREE-MRI在>60 mL/100 g/min区间高值更多。
  • Kolmogorov-Smirnov检验证实概率分布不同(P = 0.62)。
  • FREE-MRI近似CBF在仅使用50%采集数据时保持稳定;使用40%数据时值较90%或更多数据显著升高(P ≤ 0.05)。
  • 白质内值在数据缩减后无显著变化;全局及体素wise与pCASL-MRI的相关系数在FREE-MRI数据缩减期间保持稳定。

局限性

  • 需进一步序列优化以改善相对低灌注组织的测量。
  • 原文结论指出所提出技术仅允许对CBF进行粗略近似。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: First, to test the feasibility of cerebral blood flow (CBF) estimation using the pulse wave amplitude in flow-related enhancement (FREE) brain MRI in comparison to pseudo-continuous arterial spin labeling (pCASL-MRI). Second, the potential for acceleration was evaluated retrospectively.

MATERIALS AND METHODS: 24 healthy study participants between 20 and 61 years had cerebral MRI. Perfusion imaging was performed with a balanced steady-state free precession sequence for FREE-MRI and with pCASL-MRI for comparison.

RESULTS: The value distribution of the estimated CBF showed a high overlap in the histogram between 0 and 20 mL/100 g/min. However, disparity of the values occurred with more values between 20 and 60 mL/100 g/min using pCASL-MRI and more high values > 60 mL/100 g/min applying FREE-MRI. A Kolmogorov-Smirnov test confirmed a differing probability distribution (P = 0.62). The approximated CBF from FREE-MRI remained stable until only 50% of the acquired data was used. Values from using 40% of the data increased significantly compared to 90% or more (P ≤ 0.05). Values within the white matter presented no significant change after data reduction. The global and voxel-wise correlation coefficients towards pCASL-MRI presented stability during data reduction of FREE-MRI.

CONCLUSION: In conclusion, the proposed technique allows a rough approximation of the CBF compared to pCASL-MRI. Further sequence optimization must be achieved to improve the measurement of relatively lowly perfused tissues. Nevertheless, it offers large potential for imaging speed optimization and enables perfusion-weighted images similarly to the color Doppler mode in ultrasound.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Glandorf J, Klimeš F, Kern AL, et al. Estimation of Cerebral Blood Flow Using the Pulse Wave Amplitude in Brain MRI. Acad Radiol. 2024. PMID: 38664144. doi:10.1016/j.acra.2024.03.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。