文献速递神经MR

自发性低颅压:探索非增强FLAIR替代增强T1WI评估硬脑膜增厚的可行性

Spontaneous intracranial hypotension: Exploring the viability of non-contrast FLAIR as a substitute for contrast-enhanced T1WI in assessing pachymeningeal thickening.
PubMed 文献 · Neuroradiology · 2024-04-25

本研究为单中心回顾性研究,纳入43例临床诊断的自发性低颅压患者,以增强T1WI为金标准,评估非增强FLAIR上弥漫性硬脑膜高信号替代弥漫性硬脑膜强化判断硬脑膜增厚的可行性。FLAIR判断硬脑膜增厚的准确度、敏感度、特异度、阳性预测值和阴性预测值分别为72.1%、71.8%、75.0%、96.6%和21.4%,假阴性率28.2%。作者结论认为FLAIR与T1ce在识别硬脑膜增厚上缺乏完全一致性,在去除增强扫描时需谨慎。

要点

  • FLAIR判断硬脑膜增厚的敏感度71.8%、特异度75.0%,阴性预测值仅21.4%。
  • FLAIR假阴性率28.2%(11/39),可漏诊部分硬脑膜增厚病例。
  • FLAIR发现的28例硬脑膜高信号中,21例(75%)受硬膜下积液影响。

核心结论

  • FLAIR与增强T1WI在识别硬脑膜增厚上缺乏完全一致性,去除增强扫描需谨慎,因为硬脑膜强化是Bern评分的主要标准之一。

研究设计与样本

  • 单中心回顾性研究,纳入2021年4月至2023年11月间43例临床诊断的自发性低颅压患者,使用1.5T和3.0T MRI扫描仪行脑MRI检查,以增强T1WI作为硬脑膜增厚的金标准,由两名放射科医师独立评估FLAIR上弥漫性硬脑膜高信号和增强T1WI上弥漫性硬脑膜强化。

诊断标准与关键数值

  • 以增强T1WI为金标准,FLAIR判断硬脑膜增厚的准确度72.1%、敏感度71.8%、特异度75.0%、阳性预测值96.6%、阴性预测值21.4%;43例中39例(90.7%)增强T1WI显示硬脑膜增厚;FLAIR识别硬脑膜增厚28例,其中21例(75%)硬脑膜高信号受硬膜下积液影响;FLAIR假阴性率28.2%(11/39)。

临床应用与阅片要点

  • 作者结论认为FLAIR与增强T1WI在识别硬脑膜增厚上缺乏完全一致性,提示在自发性低颅压患者的MRI方案中去除增强扫描时需谨慎,因为硬脑膜强化是Bern评分的主要标准之一。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To avoid contrast administration in spontaneous intracranial hypotension (SIH), some studies suggest accepting diffuse pachymeningeal hyperintensity (DPMH) on non-contrast fluid-attenuated inversion recovery (FLAIR) as an equivalent sign to diffuse pachymeningeal enhancement (DPME) on contrast-enhanced T1WI (T1ce), despite lacking thorough performance metrics. This study aimed to comprehensively explore its feasibility.

METHODS: In this single-center retrospective study, between April 2021 and November 2023, brain MRI examinations of 43 patients clinically diagnosed with SIH were assessed using 1.5 and 3.0 Tesla MRI scanners. Two radiologists independently assessed the presence or absence of DPMH on FLAIR and DPME on T1ce, with T1ce serving as a gold-standard for pachymeningeal thickening. The contribution of the subdural fluid collections to DPMH was investigated with quantitative measurements. Using Cohen's kappa statistics, interobserver agreement was assessed.

RESULTS: In 39 out of 43 patients (90.7%), pachymeningeal thickening was observed on T1ce. FLAIR sequence produced an accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 72.1%, 71.8%, 75.0%, 96.6%, and 21.4% respectively, for determining pachymeningeal thickening. FLAIR identified pachymeningeal thickening in 28 cases; however, among these, 21 cases (75%) revealed that the pachymeningeal hyperintense signal was influenced by subdural fluid collections. False-negative rate for FLAIR was 28.2% (11/39).

CONCLUSION: The lack of complete correlation between FLAIR and T1ce in identifying pachymeningeal thickening highlights the need for caution in removing contrast agent administration from the MRI protocol of SIH patients, as it reveals a major criterion (i.e., pachymeningeal enhancement) of Bern score.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Yuzkan S, Benlice T, Guzelbey T, et al. Spontaneous intracranial hypotension: Exploring the viability of non-contrast FLAIR as a substitute for contrast-enhanced T1WI in assessing pachymeningeal thickening. Neuroradiology. 2024. PMID: 38658472. doi:10.1007/s00234-024-03359-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。