大鼠脑暴露于诊断超声后的神经炎症

Neuroinflammation in the Rat Brain After Exposure to Diagnostic Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2024-01-01

研究将12只Wistar大鼠分为对照组与超声暴露组(每组6只),开颅后以B模式与频谱多普勒探测大脑中动脉10分钟,48小时后取脑用IBA-1与GFAP免疫组化分析。超声暴露组各区域IBA-1与GFAP免疫反应细胞面密度均较对照组显著增加(p < 0.001)。作者认为10分钟B模式与多普勒超声可能诱导大鼠脑神经炎症改变。

要点

  • 大鼠开颅后B模式与多普勒超声探测10分钟,48小时后脑组织IBA-1与GFAP免疫反应细胞面密度较对照组显著增加(p < 0.001)。
  • 作者认为暴露于当前诊断超声强度可能并非完全无风险。

核心结论

  • 10分钟B模式与多普勒超声可能诱导大鼠脑神经炎症改变,提示脑组织暴露于当前诊断超声强度可能并非完全无风险。

研究设计与样本

  • 动物实验:12只7-9周龄Wistar大鼠分为对照组与超声暴露组(每组6只),开颅后超声组行10分钟B模式与频谱多普勒大脑中动脉探测,对照组行假处理(探头固定于开颅处但超声机机关闭),48小时后处死取脑行IBA-1与GFAP免疫组化分析。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To date there have been no studies exploring the potential for neuroinflammation as an intracranial bio-effect associated with diagnostic ultrasound during neonatal cranial scans in a mammalian in vivo model. The study described here was aimed at investigating the effects of B-mode and Doppler mode ultrasound on inflammation in the rat brain.

METHODS: Twelve Wistar rats (7-9 wk old) were divided into a control group and an ultrasound-exposed group (n = 6/group). A craniotomy was performed, followed by 10 min of B-mode and spectral Doppler interrogation of the middle cerebral artery. The control group was subjected to sham treatment, with the transducer held stationary over the craniotomy site, but the ultrasound machine switched off. Animals were euthanized 48 h after exposure, and the brains formalin fixed for immunohistochemical analysis using allograft inflammatory factor 1 (IBA-1) and glial fibrillary acidic protein (GFAP) as markers of microglia and astrocytes, respectively. The numbers of IBA-1- and GFAP-immunoreactive cells were manually counted and expressed as areal density (cells/mm2). Results were analyzed using Student's unpaired t-test and one-way repeated-measures analysis of variance.

RESULTS: The ultrasound-exposed brain exhibited significant increases in IBA-1 and GFAP immunoreactive cell density in all regions of B-mode and Doppler mode exposure compared with the control group (p < 0.001).

CONCLUSION: Ten minutes of B-mode and Doppler mode ultrasound may induce neuroinflammatory changes in the rat brain. This suggests that exposure of brain tissue to current diagnostic ultrasound intensities may not be completely without risk.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。