文献速递腹部技术与安全CT

深度学习图像重建提升低剂量双能CT小肠造影整体图像质量

Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction.
PubMed 文献 · Abdom Radiol (NY) · 2024-03-14

前瞻性研究纳入86例接受双能CT小肠造影者,早期肠期用标准剂量(噪声指数8)ASIR-V40%重建5 mm和1.25 mm图像,晚期肠期用低剂量(噪声指数12)ASIR-V40%、DLIR-M和DLIR-H重建1.25 mm图像。晚期肠期辐射剂量较早期肠期降低50%,低剂量1.25 mm DLIR-H图像噪声、SNR、CNR与标准剂量5 mm ASIR-V40%图像相似,但图像对比度、肠壁锐利度、肠系膜血管清晰度和小结构可见性评分显著更高。

要点

  • 低剂量1.25 mm DLIR-H图像在图像对比度、肠壁锐利度、肠系膜血管清晰度及小结构可见性上优于标准剂量5 mm ASIR-V40%图像。
  • 低剂量1.25 mm DLIR-H与标准剂量5 mm ASIR-V40%的噪声、SNR、CNR相似,但前者辐射剂量降低50%。
  • 在1.25 mm层厚下,DLIR-M和DLIR-H的客观与主观图像质量均显著优于ASIR-V40%。

核心结论

  • 在双能CT小肠造影中,与常规ASIR-V40% 5 mm图像相比,DLIR在相同层厚下显著降低图像噪声,但采用更薄层厚时显著提高空间分辨率和病灶可见性,同时辐射剂量降低50%。

研究设计与样本

  • 经机构审查委员会批准的前瞻性研究,纳入86例接受双能CT小肠造影的受试者;早期肠期采用标准剂量(噪声指数8)扫描并以ASIR-V40%重建5 mm和1.25 mm图像,晚期肠期采用低剂量(噪声指数12)扫描并以ASIR-V40%、DLIR-M和DLIR-H重建1.25 mm图像;图像比较与分析均使用70 keV单能图像。

诊断标准与关键数值

  • 早期肠期标准剂量(噪声指数8)扫描,ASIR-V40%重建5 mm和1.25 mm图像。
  • 晚期肠期低剂量(噪声指数12)扫描,ASIR-V40%、DLIR-M和DLIR-H重建1.25 mm图像。
  • 客观评估指标为图像噪声、伪影指数、SNR和CNR;主观评估由两名放射科医师盲法对主观噪声、图像对比度、肠壁锐利度、肠系膜血管清晰度和小结构可见性评分。
  • 低剂量1.25 mm DLIR-H图像噪声、SNR、CNR与标准剂量5 mm ASIR-V40%图像相似,但图像对比度[5(5-5), P < 0.05]、肠壁锐利度[5(5-5), P < 0.05]、肠系膜血管清晰度[5(5-5), P < 0.05]和小结构可见性[5(5-5), P < 0.05]评分显著更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To demonstrate the clinical advantages of a deep-learning image reconstruction (DLIR) in low-dose dual-energy computed tomography enterography (DECTE) by comparing images with standard-dose adaptive iterative reconstruction-Veo (ASIR-V) images.

METHODS: In this Institutional review board approved prospective study, 86 participants who underwent DECTE were enrolled. The early-enteric phase scan was performed using standard-dose (noise index: 8) and images were reconstructed at 5 mm and 1.25 mm slice thickness with ASIR-V at a level of 40% (ASIR-V40%). The late-enteric phase scan used low-dose (noise index: 12) and images were reconstructed at 1.25 mm slice thickness with ASIR-V40%, and DLIR at medium (DLIR-M) and high (DLIR-H). The 70 keV monochromatic images were used for image comparison and analysis. For objective assessment, image noise, artifact index, SNR and CNR were measured. For subjective assessment, subjective noise, image contrast, bowel wall sharpness, mesenteric vessel clarity, and small structure visibility were scored by two radiologists blindly. Radiation dose was compared between the early- and late-enteric phases.

RESULTS: Radiation dose was reduced by 50% in the late-enteric phase [(6.31 ± 1.67) mSv] compared with the early-enteric phase [(3.01 ± 1.09) mSv]. For the 1.25 mm images, DLIR-M and DLIR-H significantly improved both objective and subjective image quality compared to those with ASIR-V40%. The low-dose 1.25 mm DLIR-H images had similar image noise, SNR, CNR values as the standard-dose 5 mm ASIR-V40% images, but significantly higher scores in image contrast [5(5-5), P < 0.05], bowel wall sharpness [5(5-5), P < 0.05], mesenteric vessel clarity [5(5-5), P < 0.05] and small structure visibility [5(5-5), P < 0.05].

CONCLUSIONS: DLIR significantly reduces image noise at the same slice thickness, but significantly improves spatial resolution and lesion conspicuity with thinner slice thickness in DECTE, compared to conventional ASIR-V40% 5 mm images, all while providing 50% radiation dose reduction.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Lin X, Gao Y, Zhu C, et al. Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction. Abdom Radiol (NY). 2024. PMID: 38480547. doi:10.1007/s00261-024-04221-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。