文献速递儿科影像骨肌US

超声次要征象诊断儿童远端前臂骨折:一项诊断性研究

Ultrasound Secondary Signs for the Diagnosis of Pediatric Distal Forearm Fractures: A Diagnostic Study.
PubMed 文献 · Ultrasound Med Biol · 2024-03-21

该诊断性研究在澳大利亚昆士兰州东南部纳入135例5-15岁临床无畸形远端前臂损伤患儿,由急诊医师行床旁超声记录骨折次要征象,以专家小组最终骨折诊断为参考标准。旋前方肌血肿征诊断皮质断裂骨折敏感度91%、特异度82%;骨折线至骺板距离<1cm诊断Salter-Harris II型骨折敏感度100%、特异度85%。作者认为超声次要征象对皮质断裂骨折和Salter-Harris II型骨折均有良好诊断准确性,未来研究应考虑优化次要征象的使用以提高诊断准确性。

要点

  • 旋前方肌血肿征诊断皮质断裂骨折敏感度91%(95%CI 78%-97%)、特异度82%(73%-88%)。
  • 骨折线至骺板距离<1cm诊断Salter-Harris II型骨折敏感度100%(80%-100%)、特异度85%(78%-90%)。
  • 可见成角与骨膜血肿征敏感度差但特异度高;骺板改变敏感度40%(20%-64%)、特异度99%(95%-100%)。

核心结论

  • 超声次要征象对皮质断裂骨折和Salter-Harris II型骨折均显示出良好的诊断准确性。
  • 未来研究应考虑优化次要征象的使用以提高诊断准确性。

研究设计与样本

  • 诊断性研究,在澳大利亚昆士兰州东南部开展,共纳入135例参与者。
  • 研究对象为5-15岁、因临床无畸形远端前臂损伤就诊于急诊科的患者。
  • 由急诊医师对符合条件患者行床旁超声,记录骨折次要征象(旋前方肌血肿征、骨膜血肿、可见成角)或骺板骨折征象(骨折线至骺板距离、骺板改变)。
  • 参考标准为专家小组确定的最终骨折诊断。
  • 主要结局为次要征象诊断皮质断裂骨折和骺板骨折的准确性。

关键影像表现/征象

  • 专家小组诊断无骨折48例、青枝骨折52例、其他骨折35例。
  • 所有其他骨折均为皮质断裂骨折,其中包含15例Salter-Harris II型骨折。

诊断标准与关键数值

  • 旋前方肌血肿征诊断皮质断裂骨折:敏感度91%(95%CI 78%-97%),特异度82%(95%CI 73%-88%)。
  • 可见成角与骨膜血肿征诊断皮质断裂骨折:敏感度差、特异度高。
  • 骨折线至骺板距离<1cm诊断Salter-Harris II型骨折:敏感度100%(95%CI 80%-100%),特异度85%(95%CI 78%-90%)。
  • 骺板改变诊断Salter-Harris II型骨折:敏感度40%(95%CI 20%-64%),特异度99%(95%CI 95%-100%)。

临床应用与阅片要点

  • 急诊医师行床旁超声时可记录旋前方肌血肿征,其诊断皮质断裂骨折敏感度91%、特异度82%。
  • 评估Salter-Harris II型骨折时可测量骨折线至骺板距离,<1cm时敏感度100%、特异度85%。
  • 骺板改变特异度99%(95%CI 95%-100%)但敏感度仅40%(95%CI 20%-64%)。
  • 可见成角与骨膜血肿征敏感度差但特异度高。
  • 作者认为未来研究应考虑优化次要征象的使用以提高诊断准确性。

局限性

  • 作者指出未来研究应考虑优化次要征象的使用以提高诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic accuracy of ultrasound secondary signs of fractures in pediatric patients aged 5-15 y presenting to the emergency department with a clinically non-deformed distal forearm injury.

METHODS: This diagnostic study was conducted in South East Queensland, Australia. Emergency clinicians performed point-of-care ultrasound on eligible patients and recorded secondary signs of fractures (pronator quadratus hematoma [PQH] sign, periosteal hematoma, visible angulation) or physeal fractures (fracture-to-physis distance [FPD], physis alteration). The reference standard was the final fracture diagnosis determined by expert panel. The primary outcome was the diagnostic accuracy of secondary signs for cortical breach and physeal fractures. Diagnostic statistics were reported for each relevant secondary sign.

RESULTS: A total of 135 participants were enrolled. The expert panel diagnosed 48 "no" fracture, 52 "buckle" fracture and 35 "other" fracture. All "other" fractures were cortical breach fractures and included 15 Salter-Harris II fractures. The PQH sign demonstrated high sensitivity and moderate specificity to diagnose cortical breach fractures (91%, 95% Confidence Interval [CI] 78%-97% and 82%, 73%-88%). Poor sensitivity but high specificity was observed for the visible angulation and periosteal hematoma secondary signs. FPD <1cm showed perfect sensitivity and moderate specificity (100%, 80%-100% and 85%, 78%-90%) for diagnosis of Salter-Harris II fracture. Conversely, physis alteration showed poor sensitivity but excellent specificity (40%, 20%-64% and 99%, 95%-100%) for the diagnosis of Salter-Harris II fractures.

CONCLUSION: Ultrasound secondary signs showed good diagnostic accuracy for both cortical breach fractures and Salter-Harris II fractures. Future research should consider optimal use of secondary signs to improve diagnostic accuracy.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Snelling PJ, Jones P, Bade D, et al. Ultrasound Secondary Signs for the Diagnosis of Pediatric Distal Forearm Fractures: A Diagnostic Study. Ultrasound Med Biol. 2024. PMID: 38519361. doi:10.1016/j.ultrasmedbio.2024.02.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。