文献速递骨肌CTDR

下肢力线评估:仰卧位负重CT扫描图与站立位全长X线片的比较

Assessment of lower limb alignment: supine weight-bearing CT scanograms compared with a standing full-length radiograph.
PubMed 文献 · Skeletal Radiol · 2024-03-05

本研究前瞻性比较46组仰卧位负重CT扫描图与站立位下肢全长前后位X线片测量的负重线比率、髋-膝-踝角和关节汇聚角。负重CT通过施加零至全身体重六种轴向力实现。站立位X线片与仰卧位CT扫描图的平均绝对差异为负重线比率4.32%、髋-膝-踝角1.25°、关节汇聚角0.46,施加全身体重轴向压力时差异最小。结论认为全身体重仰卧位负重CT扫描图与站立位X线片评估下肢力线无显著差异。

要点

  • 仰卧位负重CT扫描图施加全身体重轴向压力时,与站立位X线片测得的力线参数差异最小。
  • 负重线比率平均绝对差异4.32%,髋-膝-踝角1.25°,关节汇聚角0.46。
  • 年龄、体质指数、髋-膝-踝角和关节汇聚角对全身体重下的力线偏差无影响。

核心结论

  • 站立位X线片与全身体重仰卧位负重CT扫描图评估下肢力线无显著差异,负重CT扫描图可作为仰卧位评估下肢力线的有价值方法。

研究设计与样本

  • 前瞻性研究,纳入46组配对测量,比较仰卧位负重CT扫描图与站立位下肢全长前后位X线片;CT扫描时施加零、1/5、2/5、3/5、4/5及全身体重六种轴向力。

诊断标准与关键数值

  • 站立位X线片与仰卧位CT扫描图的平均绝对差异:负重线比率4.32%(p < 0.05),髋-膝-踝角1.25°(p < 0.05),关节汇聚角0.46(p < 0.05);施加全身体重轴向压力时平均绝对差异最小(p > 0.05)。

临床应用与阅片要点

  • 作者认为全身体重仰卧位负重CT扫描图是评估仰卧位下肢力线的有价值方法;年龄、体质指数、髋-膝-踝角和关节汇聚角对全身体重下的力线测量偏差无影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We identified limb misalignment by applying personalized axial force while the limb was in a supine position to mimic a standing posture. This study aimed to confirm the accuracy of evaluating lower limb alignment using supine weight-bearing CT scanograms.

METHODS: We prospectively compared measurements of the weight-bearing line ratio (WBL), hip-knee-ankle (HKA) angle, and joint convergence angle (JLCA) in 46 sets of supine weight-bearing CT scanograms with those obtained from full-length standing anteroposterior lower extremity radiographs. We achieved the weight-bearing CT scanograms by applying six different levels of axial force: zero, 1/5 of body weight, 2/5 of body weight, 3/5 of body weight, 4/5 of body weight, and full body weight. We assessed the impact of age, body mass index, HKA, and JLCA on the observed mechanical axis deviation differences between the two methods.

RESULT: The average absolute difference between standing radiographs and supine CT scanograms was 4.32% for the WBL ratio (p < 0.05), 1.25° for HKA (p < 0.05), and 0.46 for JLCA (p < 0.05). The mean absolute difference was minimal when applying full body weight axial pressure during CT scanograms (p > 0.05). Age, body mass index, HKA, and JLCA had no effect on the deviation in the mechanical axis measurements obtained through supine weight-bearing CT scanograms with full body weight.

CONCLUSION: No significant differences were found in assessing lower limb alignment between standing radiographs and supine weight-bearing CT scanograms with full body weight. Weight-bearing CT scanograms prove to be a valuable method for assessing lower limb alignment while in a supine position.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Liu X, Zhang B, Zhao C, et al. Assessment of lower limb alignment: supine weight-bearing CT scanograms compared with a standing full-length radiograph. Skeletal Radiol. 2024. PMID: 38443696. doi:10.1007/s00256-024-04637-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。