高分辨率扩散加权MRI联合乳腺X线摄影检测致密乳腺女性临床隐匿性乳腺癌
回顾性分析281例连续无症状致密乳腺女性共544侧乳腺,比较乳腺X线摄影、高分辨率DW-MRI、DCE-MRI及其联合检测临床隐匿性乳腺癌的效能。DW-MRI敏感度高于乳腺X线摄影(77.0% vs 57.9%)但低于DCE-MRI(84.8%),特异度与两者相当;DW-MRI联合乳腺X线摄影的敏感度和特异度与DCE-MRI联合乳腺X线摄影相当(88.6% vs 90.9%和97.1% vs 96.2%)。
要点
- 致密乳腺女性中,DW-MRI联合乳腺X线摄影检测临床隐匿性乳腺癌的敏感度和特异度与DCE-MRI联合乳腺X线摄影相当。
- DW-MRI敏感度(77.0%)高于乳腺X线摄影(57.9%),但低于DCE-MRI(84.8%)。
- DW-MRI特异度(98.1%)与乳腺X线摄影(99.1%)及DCE-MRI(97.1%)相当。
核心结论
- 高分辨率DW-MRI敏感度高于乳腺X线摄影、低于DCE-MRI;DW-MRI联合乳腺X线摄影检测致密乳腺女性临床隐匿性乳腺癌的敏感度和特异度与DCE-MRI联合乳腺X线摄影相当。
研究设计与样本
- 回顾性研究,连续纳入281例无症状致密乳腺女性共544侧乳腺,其中214侧为乳腺癌术前评估、67侧为补充筛查;行乳腺X线摄影及乳腺MRI(DCE-MRI和DW-MRI,b值0和1000 sec/mm²,平面内分辨率1.1×1.1 mm²和1.3×1.3 mm²,层厚3 mm);三位阅片者独立按侧乳腺判读;以组织病理学和至少2年影像随访为金标准。
诊断标准与关键数值
- 544侧乳腺中230侧(42%)有恶性病变;DW-MRI敏感度77.0% vs 乳腺X线摄影57.9%(校正P<0.001),DW-MRI敏感度77.0% vs DCE-MRI84.8%(校正P=0.014);DW-MRI特异度98.1% vs 乳腺X线摄影99.1%(校正P>0.999),DW-MRI特异度98.1% vs DCE-MRI97.1%(校正P>0.999);DW-MRI联合乳腺X线摄影 vs DCE-MRI联合乳腺X线摄影敏感度88.6% vs 90.9%、特异度97.1% vs 96.2%(校正P均>0.999)。
临床应用与阅片要点
- 在致密乳腺女性中,DW-MRI联合乳腺X线摄影可作为检测临床隐匿性乳腺癌的候选方案,其敏感度和特异度与DCE-MRI联合乳腺X线摄影相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the performance of mammography, high-resolution DW-MRI, DCE-MRI, and their combinations in detecting clinically occult breast cancer in women with dense breasts.
METHOD: 544 breasts from 281 consecutive asymptomatic women with dense breasts were retrospectively identified. They underwent breast MRI for preoperative evaluation of breast cancers (n = 214) or as supplemental screening (n = 67) including DCE-MRI and DW-MRI (b values, 0 and 1000 sec/mm2; in-plane resolution, 1.1 × 1.1 mm2 and 1.3 × 1.3 mm2; section thickness, 3 mm), in addition to mammography. Three readers independently reviewed each examination on a per-breast basis. Histopathology and at least two year of imaging follow-up served as the gold standard. The sensitivities and specificities of different imaging modalities were compared using McNemar test.
RESULTS: 230 of 544 breasts (42 %) had malignant lesions. The sensitivity of DW-MRI was higher than that of mammography (77.0 % vs 57.9 %; adjusted p < 0.001), but lower than that of DCE-MRI (84.8 %; adjusted p = 0.014). The specificity of DW-MRI was comparable to those of mammography (98.1 % vs 99.1 %; adjusted p > 0.999) and DCE-MRI (97.1 %; adjusted p > 0.999). DW-MRI plus mammography had a comparable sensitivity and specificity to those of DCE-MRI plus mammography (88.6 % vs 90.9 % and 97.1 % vs 96.2 %; adjusted p > 0.999 for both).
CONCLUSIONS: High-resolution DW-MRI had a sensitivity higher than mammography and lower than DCE-MRI. Nevertheless, DW-MRI plus mammography showed a comparable sensitivity and specificity to DCE-MRI plus mammography for detecting clinically occult cancers in women with dense breasts.
引用
- Kim HJ, Shin HJ, Baek S, et al. High-resolution diffusion-weighted MRI plus mammography for detecting clinically occult breast cancers in women with dense breasts. Eur J Radiol. 2024. PMID: 38547744. doi:10.1016/j.ejrad.2024.111440
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。