通过与逻辑回归模型比较机器学习模型分析乳腺X线摄影隐匿性MRI检出新生乳腺癌的相关特征
本研究为单中心回顾性研究,纳入2018年1月至2023年5月间经乳腺X线摄影和MRI(间隔不超过45天)检查的1914例乳腺癌患者共1957个恶性病灶,其中485个为乳腺X线摄影隐匿性乳腺癌。研究采用多种机器学习算法与二元逻辑回归分析提取与乳腺X线摄影隐匿性乳腺癌相关的特征并构建模型,结果显示基于随机森林特征的ANN模型预测性能最佳,AUC为0.912,准确率为86.90%,敏感度为85.85%,特异度为84.18%。
要点
- 乳腺X线摄影隐匿性乳腺癌的优化特征包括钙化状态、肿瘤大小、乳腺X线密度、年龄、MRI病灶强化类型和组织学类型。
- 在ANN、L1-LR、RF、SVM及基于LR的组合模型中,基于RF特征的ANN模型预测乳腺X线摄影假阴性表现的判别性能最佳。
- 该模型AUC为0.912,准确率86.90%,敏感度85.85%,特异度84.18%。
核心结论
- 乳腺X线摄影隐匿性MRI检出乳腺癌具有应在进行乳腺MRI时考虑的特征,以提高乳腺癌检出率并辅助临床医生管理。
研究设计与样本
- 单中心回顾性研究,纳入连续女性乳腺癌患者1914例共1957个恶性病灶,平均年龄51.64±9.92岁(范围20-86岁),均接受乳腺X线摄影和MRI检查(间隔不超过45天),采用多种机器学习算法和二元逻辑回归分析提取特征并构建模型。
关键影像表现/征象
- 乳腺X线摄影隐匿性乳腺癌的优化特征包括钙化状态、肿瘤大小、乳腺X线密度、年龄、MRI病灶强化类型和组织学类型。
诊断标准与关键数值
- 基于随机森林特征的ANN模型预测乳腺X线摄影假阴性表现性能最佳,AUC为0.912,准确率为86.90%,敏感度为85.85%,特异度为84.18%。
临床应用与阅片要点
- 进行乳腺MRI时应考虑乳腺X线摄影隐匿性乳腺癌的相关特征,以提高乳腺癌检出率并辅助临床医生管理。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare machine learning (ML) models with logistic regression model in order to identify the optimal factors associated with mammography-occult (i.e. false-negative mammographic findings) magnetic resonance imaging (MRI)-detected newly diagnosed breast cancer (BC).
MATERIAL AND METHODS: The present single-centre retrospective study included consecutive women with BC who underwent mammography and MRI (no more than 45 days apart) for breast cancer between January 2018 and May 2023. Various ML algorithms and binary logistic regression analysis were utilized to extract features linked to mammography-occult BC. These features were subsequently employed to create different models. The predictive value of these models was assessed using receiver operating characteristic curve analysis.
RESULTS: This study included 1957 malignant lesions from 1914 patients, with an average age of 51.64 ± 9.92 years and a range of 20-86 years. Among these lesions, there were 485 mammography-occult BCs. The optimal features of mammography-occult BC included calcification status, tumour size, mammographic density, age, lesion enhancement type on MRI, and histological type. Among the different ML models (ANN, L1-LR, RF, and SVM) and the LR-based combined model, the ANN model with RF features was found to be the optimal model. It demonstrated the best discriminative performance in predicting mammography false- negative findings, with an AUC of 0.912, an accuracy of 86.90%, a sensitivity of 85.85%, and a specificity of 84.18%.
CONCLUSION: Mammography-occult MRI-detected breast cancers have features that should be considered when performing breast MRI to improve the detection rate for breast cancer and aid in clinician management.
引用
- Yang W, Yang Y, Zhang N, et al. The features associated with mammography-occult MRI-detected newly diagnosed breast cancer analysed by comparing machine learning models with a logistic regression model. Radiol Med. 2024. PMID: 38512623. doi:10.1007/s11547-024-01804-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。