文献速递乳腺USMR乳腺X线

多参数超声列线图的开发用于预测导管原位癌的浸润性

Development of a Multi-Parametric ultrasonography nomogram for prediction of invasiveness in ductal carcinoma in situ.
PubMed 文献 · Eur J Radiol · 2024-03-06

前瞻性纳入2017年1月至2022年12月基于MRI或乳腺X线摄影怀疑导管原位癌(DCIS)的连续患者,以手术切除后组织病理学为金标准,采用二元logistic回归从多参数超声中筛选独立危险因素并构建列线图。共纳入249例患者的250个DCIS病灶(85个纯DCIS,165个DCIS伴浸润,其中41个微浸润)。多参数超声预测DCIS伴浸润的敏感度89.7%、特异度73.8%、AUC 0.903,列线图AUC 0.889;预测微浸润的列线图AUC 0.867。作者认为列线图因AUC低于0.9阈值目前尚不被视为临床可用的诊断工具。

要点

  • 多参数超声预测DCIS伴浸润的独立危险因素包括图像大小>2cm、多普勒超声RI≥0.72、SWE的Emax≥66.4 kPa、高增强、向心性增强、周围血管增多及CEUS无对比剂滞留。
  • 多参数超声预测DCIS伴浸润的敏感度89.7%、特异度73.8%、AUC 0.903,优于单一超声模态或联合SWE或CEUS的模态。
  • 预测DCIS微浸润的列线图纳入RI≥0.72、SWE的Emax≥65.2 kPa和向心性增强,AUC为0.867。

核心结论

  • 多参数超声通过分析病灶形态、硬度、新生血管结构和灌注,对预测DCIS伴浸润和微浸润均显示出良好的判别能力;基于超声图像构建的列线图为评估DCIS浸润风险提供了直观有效的方法。

研究设计与样本

  • 前瞻性研究,连续纳入2017年1月至2022年12月基于MRI或乳腺X线摄影怀疑DCIS的患者,以手术切除后组织病理学为金标准,术前行灰阶超声、多普勒超声、剪切波弹性成像(SWE)和对比增强超声(CEUS)检查,采用二元logistic回归进行多因素分析。

关键影像表现/征象

  • 多参数超声预测DCIS伴浸润的独立危险因素包括图像大小>2cm、多普勒超声RI≥0.72、SWE的Emax≥66.4 kPa、高增强、向心性增强、周围血管增多及CEUS无对比剂滞留。
  • 上述独立危险因素与组织学分级、Ki-67和人表皮生长因子受体2(HER2)相关(P < 0.1)。
  • 预测DCIS微浸润的独立危险因素包括RI≥0.72、SWE的Emax≥65.2 kPa和向心性增强。

诊断标准与关键数值

  • 多参数超声预测DCIS伴浸润:敏感度89.7%、特异度73.8%、AUC 0.903。
  • 基于多参数超声独立危险因素构建的预测DCIS伴浸润列线图:AUC 0.889。
  • 预测DCIS微浸润列线图(纳入RI≥0.72、SWE的Emax≥65.2 kPa、向心性增强):AUC 0.867。
  • 多参数超声预测DCIS伴浸润的AUC 0.903优于单一超声模态或联合SWE或CEUS的模态。

临床应用与阅片要点

  • 作者认为,基于超声图像构建的列线图为评估DCIS浸润风险提供了直观有效的方法。
  • 作者指出,列线图因AUC低于0.9阈值,目前尚不被视为临床可用的诊断工具。
  • 作者期待进一步研究和发展能产生积极结果并提高其临床应用的可行性。

局限性

  • 作者指出,列线图因AUC低于0.9阈值,目前尚不被视为临床可用的诊断工具。
  • 作者期待进一步研究和发展能产生积极结果并提高其临床应用的可行性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the independent risk variables associated with the potential invasiveness of ductal carcinoma in situ (DCIS) on multi-parametric ultrasonography, and further construct a nomogram for risk assessment.

METHODS: Consecutive patients from January 2017 to December 2022 who were suspected of having ductal carcinoma in situ (DCIS) based on magnetic resonance imaging or mammography were prospectively enrolled. Histopathological findings after surgical resection served as the gold standard. Grayscale ultrasound, Doppler ultrasound, shear wave elastography (SWE), and contrast-enhanced ultrasound (CEUS) examinations were preoperative performed. Binary logistic regression was used for multifactorial analysis to identify independent risk factors from multi-parametric ultrasonography. The correlation between independent risk factors and pathological prognostic markers was analyzed. The predictive efficacy of DCIS associated with invasiveness was assessed by logistic analysis, and a nomogram was established.

RESULTS: A total of 250 DCIS lesions were enrolled from 249 patients, comprising 85 pure DCIS and 165 DCIS with invasion (DCIS-IDC), of which 41 exhibited micro-invasion. The multivariate analysis identified independent risk factors for DCIS with invasion on multi-parametric ultrasonography, including image size (>2cm), Doppler ultrasound RI (≥0.72), SWE's Emax (≥66.4 kPa), hyper-enhancement, centripetal enhancement, increased surrounding vessel, and no contrast agent retention on CEUS. These factors correlated with histological grade, Ki-67, and human epidermal growth factor receptor 2 (HER2) (P < 0.1). The multi-parametric ultrasound approach demonstrated good predictive performance (sensitivity 89.7 %, specificity 73.8 %, AUC 0.903), surpassing single US modality or combinations with SWE or CEUS modalities. Utilizing these factors, a predictive nomogram achieved a respectable performance (AUC of 0.889) for predicting DCIS with invasion. Additionally, a separate nomogram for predicting DCIS with micro-invasion, incorporating independent risk factors such as RI (≥0.72), SWE's Emax (≥65.2 kPa), and centripetal enhancement, demonstrated an AUC of 0.867.

CONCLUSION: Multi-parametric ultrasonography demonstrates good discriminatory ability in predicting both DCIS with invasion and micro-invasion through the analysis of lesion morphology, stiffness, neovascular architecture, and perfusion. The use of a nomogram based on ultrasonographic images offers an intuitive and effective method for assessing the risk of invasion in DCIS. Although the nomogram is not currently considered a clinically applicable diagnostic tool due to its AUC being below the threshold of 0.9, further research and development are anticipated to yield positive outcomes and enhance its viability for clinical utilization.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Niu Q, Li H, Du L, et al. Development of a Multi-Parametric ultrasonography nomogram for prediction of invasiveness in ductal carcinoma in situ. Eur J Radiol. 2024. PMID: 38471320. doi:10.1016/j.ejrad.2024.111415

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。