剪切波弹性成像与超声引导弥散光学断层成像定量分析评估乳腺癌生物学特征的可行性研究
本研究纳入235例乳腺癌患者的238个病灶,术前1至3天行B超、超声引导弥散光学断层成像(US-guided DOT)与剪切波弹性成像(SWE),测量总血红蛋白浓度(THC)及弹性参数并与术后病理对照。ER-、PR-、HER2+、高Ki67、LVI+和ALN+组病灶的THC、Emax和Esd高于对应组,THC与Emax等弹性参数呈正相关,提示两种技术可用于乳腺癌生物学特征的定量评估。
要点
- ER-、PR-、HER2+、高Ki67、LVI+、ALN+组病灶的THC、Emax和Esd均高于对应组,为阅片时关注的功能与弹性指标提供参考。
- THC与Emax(r=0.340,P<0.001)、Emean(r=0.201,P=0.003)、Esd(r=0.313,P<0.001)及Smax(r=0.340,P<0.001)正相关。
- US-guided DOT与SWE可定量评估乳腺癌生物学特征,THC与Emax、Emean、Esd正相关。
核心结论
- US-guided DOT与SWE对乳腺癌生物学特征的定量评估有价值,THC与Emax、Emean、Esd呈正相关。
研究设计与样本
- 研究纳入235例乳腺癌患者的238个病灶,计划于1至3天内手术,术前行B超、US-guided DOT与SWE,测量THC、Emax、Emean、Esd、Smax及面积比,并与术后病理报告对照。
诊断标准与关键数值
- ER-、PR-、HER2+、高Ki67、LVI+和ALN+组病灶的THC、Emax和Esd高于ER+、PR+、HER2-、低Ki67、LVI-和ALN-组。
- THC与Smax(r=0.340,P<0.001)、Emax(r=0.339,P<0.001)、Emean(r=0.201,P=0.003)、Esd(r=0.313,P<0.001)呈正相关。
- IDC-I至III级均可见上述升高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Shear Wave Elastography (SWE) and Ultrasound-guided Diffuse Optical Tomography (US-guided DOT) demonstrate promise in distinguishing between benign and malignant breast lesions. This study aims to assess the feasibility and correlation of SWE and US-guided DOT in evaluating the biological characteristics of breast cancer.
MATERIALS AND METHODS: A cohort of 235 breast cancer patients with 238 lesions, scheduled for surgery within one to three days, underwent B-mode ultrasound (US), US-guided DOT, and SWE. Parameters such as Total Hemoglobin Concentration (THC), Maximal Elasticity (Emax), Mean Elasticity (Emean), Standard Deviation of Elasticity (Esd), and Area Ratio were measured. Correlation with post-surgical pathology reports was examined to explore associations between THC, SWE Parameters, and pathology characteristics.
RESULTS: Lesions in patient groups with ER-, PR-, HER2 + , high Ki67, LVI+ , and ALN+ exhibited higher THC, Emax, and Esd compared to groups with ER+ , PR+ , HER2-, low Ki67, LVI-, and ALN-. The increase was seen in all grades of IDC-I to -III. THC significantly correlated with Smax (r = 0.340, P < 0.001), Emax (r = 0.339, P < 0.001), Emean (r = 0.201, P = 0.003), and Esd (r = 0.313, P < 0.001).
CONCLUSION: US-guided DOT and SWE prove valuable for the quantitative assessment of breast cancer's biological characteristics, with THC positively correlated with Emax, Emean, and Esd.
引用
- Bai L, You C, Zhou J, et al. Quantitative Analysis of Shear Wave Elastography and US-Guided Diffuse Optical Tomography for Evaluating Biological Characteristics of Breast Cancer. Acad Radiol. 2024. PMID: 38548533. doi:10.1016/j.acra.2024.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。