基于MRI的影像组学对肾脏肿块的表征:一项前瞻性先导研究中软件包间与观察者间可重复性评估
前瞻性纳入32例肾脏肿块患者(25例肾细胞癌/7例良性),用两种影像组学软件包和两名观察者评估T2WI、DWI/ADC及T1WI增强前后提取的104个特征的可重复性,并利用可重复特征构建机器学习模型鉴别肾细胞癌与良性肿块,T1WI增强后特征可重复性较好,模型AUC为0.71(95%CI 0.67-0.75)。
要点
- T1WI增强后1分钟特征在软件包间可重复性最好,良好/中等ICC占54.8-58.6%。
- 观察者间可重复性以T1WI增强后1分钟最好,良好/中等ICC达95.3-99.1%。
- ADC序列特征在软件包间和观察者间多表现为差可重复性(ICC<0.5)。
核心结论
- T1WI增强后提取的影像组学特征在软件包间和观察者间的可重复性优于ADC,机器学习模型鉴别肾细胞癌与良性肿块的AUC为0.71(95%CI 0.67-0.75),准确度尚可。
研究设计与样本
- 前瞻性先导研究,纳入32例肾脏肿块患者(23男/9女,年龄61.8±10.6岁;25例肾细胞癌/7例良性肿块;平均大小3.43±1.73 cm),均行1.5 T MRI(T2WI、DWI/ADC、T1WI增强前后),由两名独立观察者使用两种影像组学软件包对104个共同特征进行可重复性评估(n=26例),并以可重复特征(观察者间和软件包间ICC>0.8)构建机器学习模型。
诊断标准与关键数值
- 可重复性分级采用ICC:良好(ICC≥0.8)、中等(ICC=0.5-0.8)、差(ICC<0.5);软件包间T1WI增强后1分钟特征良好/中等ICC占54.8-58.6%;观察者间T1WI增强后1分钟特征良好/中等ICC占95.3-99.1%;机器学习模型鉴别肾细胞癌与良性肿块的AUC为0.71(95%CI 0.67-0.75)。
临床应用与阅片要点
- 作者指出,了解肾脏肿块MRI影像组学特征的可重复性有助于未来研究设计,并可能提升影像组学模型对肾脏肿块表征的诊断效用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate radiomics features' reproducibility using inter-package/inter-observer measurement analysis in renal masses (RMs) based on MRI and to employ machine learning (ML) models for RM characterization.
METHODS: 32 Patients (23M/9F; age 61.8 ± 10.6 years) with RMs (25 renal cell carcinomas (RCC)/7 benign masses; mean size, 3.43 ± 1.73 cm) undergoing resection were prospectively recruited. All patients underwent 1.5 T MRI with T2-weighted (T2-WI), diffusion-weighted (DWI)/apparent diffusion coefficient (ADC), and pre-/post-contrast-enhanced T1-weighted imaging (T1-WI). RMs were manually segmented using volume of interest (VOI) on T2-WI, DWI/ADC, and T1-WI pre-/post-contrast imaging (1-min, 3-min post-injection) by two independent observers using two radiomics software packages for inter-package and inter-observer assessments of shape/histogram/texture features common to both packages (104 features; n = 26 patients). Intra-class correlation coefficients (ICCs) were calculated to assess inter-observer and inter-package reproducibility of radiomics measurements [good (ICC ≥ 0.8)/moderate (ICC = 0.5-0.8)/poor (ICC < 0.5)]. ML models were employed using reproducible features (between observers and packages, ICC > 0.8) to distinguish RCC from benign RM.
RESULTS: Inter-package comparisons demonstrated that radiomics features from T1-WI-post-contrast had the highest proportion of good/moderate ICCs (54.8-58.6% for T1-WI-1 min), while most features extracted from T2-WI, T1-WI-pre-contrast, and ADC exhibited poor ICCs. Inter-observer comparisons found that radiomics measurements from T1-WI pre/post-contrast and T2-WI had the greatest proportion of features with good/moderate ICCs (95.3-99.1% T1-WI-post-contrast 1-min), while ADC measurements yielded mostly poor ICCs. ML models generated an AUC of 0.71 [95% confidence interval = 0.67-0.75] for diagnosis of RCC vs. benign RM.
CONCLUSION: Radiomics features extracted from T1-WI-post-contrast demonstrated greater inter-package and inter-observer reproducibility compared to ADC, with fair accuracy for distinguishing RCC from benign RM.
CLINICAL RELEVANCE: Knowledge of reproducibility of MRI radiomics features obtained on renal masses will aid in future study design and may enhance the diagnostic utility of radiomics models for renal mass characterization.
引用
- Al-Mubarak H, Bane O, Gillingham N, et al. Characterization of renal masses with MRI-based radiomics: assessment of inter-package and inter-observer reproducibility in a prospective pilot study. Abdom Radiol (NY). 2024. PMID: 38467854. doi:10.1007/s00261-024-04212-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。