基于模型与基于深度学习图像重建在薄层T2加权自旋回波前列腺MRI中的比较
该研究在体模和17例临床前列腺MRI受试者中比较了基于模型重建(MBIR)与基于深度学习重建(DL)在1毫米薄层T2加权自旋回波图像上的表现,结果显示DL低、中级别较MBIR提高信噪比且多数评估项更优,DL中级别在51项评估中44项被优先选择,但DL高级别降低锐利度和对比保真度。
要点
- DL重建低、中、高级别均较MBIR提高薄层T2SE前列腺图像信噪比。
- DL低、中级别在绝大多数评估项上优于MBIR,DL中级别在51项评估中44项被优先选择。
- DL高级别虽提高信噪比,但锐利度和对比保真度下降,DL低、中级别对比保真度优于DL高级别。
核心结论
- 深度学习重建法在保留图像对比度的同时显著提高1毫米薄层T2SE前列腺图像的信噪比。
- 但若将DL级别设得过高(DL高级别),放射学锐利度和对比保真度均会下降。
研究设计与样本
- 研究为实验体模定量评估加17例临床适应证受试者在3.0特斯拉下的放射学评估。
- 对每例受试者的轴位T2SE原始数据分别行MBIR及DL低、中、高三个厂商提供级别的重建。
- 采用与信噪比、锐利度、对比保真度和阅片者偏好相关的评估标准比较四种重建的薄层图像。
- 统计采用Wilcoxon符号秩检验并以Bonferroni校正,阅片者间比较采用Cohen和Krippendorf检验。
关键影像表现/征象
- 体模研究中四种重建路径的基线对比度和分辨率如预期相当。
- 在体研究中,DL低、中、高级别均较MBIR提供更高的信噪比。
- 对于几乎所有其他评估标准,DL低、中级别优于MBIR。
- DL低、中级别在对比保真度上被评估为优于DL高级别。
- 51项评估中有44项优先选择DL中级别重建。
临床应用与阅片要点
- 在薄层1毫米T2SE前列腺MRI中,DL低、中级别重建可提高信噪比并保持对比保真度,DL中级别被优先选择的频率最高。
- DL高级别重建虽提高信噪比,但锐利度和对比保真度下降,阅片时需注意级别选择对图像质量的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare a previous model-based image reconstruction (MBIR) with a newly developed deep learning (DL)-based image reconstruction for providing improved signal-to-noise ratio (SNR) in high through-plane resolution (1 mm) T2-weighted spin-echo (T2SE) prostate MRI.
METHODS: Large-area contrast and high-contrast spatial resolution of the reconstruction methods were assessed quantitatively in experimental phantom studies. The methods were next evaluated radiologically in 17 subjects at 3.0 Tesla for whom prostate MRI was clinically indicated. For each subject, the axial T2SE raw data were directed to MBIR and to the DL reconstruction at three vendor-provided levels: (L)ow, (M)edium, and (H)igh. Thin-slice images from the four reconstructions were compared using evaluation criteria related to SNR, sharpness, contrast fidelity, and reviewer preference. Results were compared using the Wilcoxon signed-rank test using Bonferroni correction, and inter-reader comparisons were done using the Cohen and Krippendorf tests.
RESULTS: Baseline contrast and resolution in phantom studies were equivalent for all four reconstruction pathways as desired. In vivo, all three DL levels (L, M, H) provided improved SNR versus MBIR. For virtually, all other evaluation criteria DL L and M were superior to MBIR. DL L and M were evaluated as superior to DL H in fidelity of contrast. For 44 of the 51 evaluations, the DL M reconstruction was preferred.
CONCLUSION: The deep learning reconstruction method provides significant SNR improvement in thin-slice (1 mm) T2SE images of the prostate while retaining image contrast. However, if taken to too high a level (DL High), both radiological sharpness and fidelity of contrast diminish.