文献速递外周血管腹部CT

深度学习图像重建改善三低方案肾动脉CT血管造影图像质量:与标准剂量单能及双能CT自适应统计迭代重建的对比研究

Improving image quality of triple-low-protocol renal artery CT angiography with deep-learning image reconstruction: a comparative study with standard-dose single-energy and dual-energy CT with adaptive statistical iterative reconstruction.
PubMed 文献 · Clin Radiol · 2024-01-23

研究纳入90例肾动脉CT血管造影患者,比较标准剂量单能CT联合60%ASIR-V、双能CT(40/70 keV联合60%ASIR-V)与三低方案(低辐射、低对比剂、低注射速度)单能CT联合DLIR-H的图像质量。三低方案组有效剂量较标准单能组和双能组分别降低37.6%和31.2%,对比剂剂量分别降低33.9%和30.5%,注射速度均降低30%,且所有动脉SD值最低(p<0.001),综合评分最佳(p<0.05)。

要点

  • 三低方案联合DLIR-H较标准单能及双能CT有效剂量降低37.6%和31.2%,对比剂剂量降低33.9%和30.5%。
  • 三低方案组所有动脉SD值最低(p<0.001),右肾动脉和左肾动脉SNR最高(p<0.05)。
  • 双能40 keV组所有动脉CNR最高(p<0.05),三低方案组综合评分最佳(p<0.05)。

核心结论

  • 三低方案肾动脉CT血管造影联合DLIR-H可显著降低有效剂量、对比剂剂量和注射速度,同时提供良好的综合图像质量。

研究设计与样本

  • 对比研究,纳入90例肾动脉CT血管造影患者,分为标准剂量单能CT组(60%ASIR-V)、双能CT组(包括40 keV和70 keV虚拟单色图像,均联合60%ASIR-V)和三低方案单能CT组(DLIR-H)。

关键影像表现/征象

  • 三低方案组所有动脉的标准差(SD)值均低于其他组(p<0.001)。
  • 三低方案组右肾动脉和左肾动脉的信噪比(SNR)最高(p<0.05)。
  • 双能40 keV组所有动脉的对比噪声比(CNR)最高(p<0.05)。

诊断标准与关键数值

  • 三低方案组较标准单能组有效剂量降低37.6%,较双能组降低31.2%。
  • 三低方案组较标准单能组对比剂剂量降低33.9%,较双能组降低30.5%。
  • 三低方案组较标准单能组和双能组注射速度均降低30%。
  • 三低方案组综合评分最佳,一致性良好(p<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the improvement in image quality of triple-low-protocol (low radiation, low contrast medium dose, low injection speed) renal artery computed tomography (CT) angiography (RACTA) using deep-learning image reconstruction (DLIR), in comparison with standard-dose single- and dual-energy CT (DECT) using adaptive statistical iterative reconstruction-Veo (ASIR-V) algorithm.

MATERIALS AND METHODS: Ninety patients for RACTA were divided into different groups: standard-dose single-energy CT (S group) using ASIR-V at 60% strength (60%ASIR-V), DECT (DE group) with 60%ASIR-V including virtual monochromatic images at 40 keV (DE40 group) and 70 keV (DE70 group), and the triple-low protocol single-energy CT (L group) with DLIR at high level (DLIR-H). The effective dose (ED), contrast medium dose, injection speed, standard deviation (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal aorta (AA), and left/right renal artery (LRA, RRA), and subjective scores were compared among the different groups.

RESULTS: The L group significantly reduced ED by 37.6% and 31.2%, contrast medium dose by 33.9% and 30.5%, and injection speed by 30% and 30%, respectively, compared to the S and DE groups. The L group had the lowest SD values for all arteries compared to the other groups (p<0.001). The SNR of RRA and LRA in the L group, and the CNR of all arteries in the DE40 group had highest value compared to others (p<0.05). The L group had the best comprehensive score with good consistency (p<0.05).

CONCLUSIONS: The triple-low protocol RACTA with DLIR-H significantly reduces the ED, contrast medium doses, and injection speed, while providing good comprehensive image quality.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Meng Z, Guo Y, Deng S, et al. Improving image quality of triple-low-protocol renal artery CT angiography with deep-learning image reconstruction: a comparative study with standard-dose single-energy and dual-energy CT with adaptive statistical iterative reconstruction. Clin Radiol. 2024. PMID: 38433041. doi:10.1016/j.crad.2024.01.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。