自由呼吸动态增强胰腺MRI采用星堆径向采样与Compressed SENSE获得适当胰腺期图像
这项回顾性研究纳入48例胰腺MRI患者,比较自由呼吸序列(4D FreeBreathing)联合Compressed SENSE与屏气序列(eTHRIVE)在动态增强胰腺MRI中的可行性。两位放射科医师独立随机评估各期图像质量及胰腺期扫描时机适当性。4D FreeBreathing在所有检查中均获得适当的胰腺期图像,而eTHRIVE仅部分检查达到适当胰腺期。
要点
- 4D FreeBreathing联合Compressed SENSE在所有20例检查中均获得适当的胰腺期图像。
- eTHRIVE序列仅16例(57%)和18例(64%)检查被两位阅片者分别判定为胰腺期适当。
- 4D FreeBreathing显示中等条纹伪影,但运动伪影在所有期相均改善(P<.001-.17)。
核心结论
- 4D FreeBreathing联合Compressed SENSE在胰腺MRI中是可行的,并在所有检查中提供了适当的胰腺期图像。
研究设计与样本
- 回顾性研究,纳入2022年4月至2023年11月期间接受胰腺MRI(eTHRIVE或4D FreeBreathing)的患者48例,中位年龄71岁(四分位距64-77岁),女性24例,其中20例(42%)使用4D FreeBreathing扫描。
关键影像表现/征象
- 4D FreeBreathing显示中等条纹伪影,但运动伪影在所有期相均改善(P<.001-.17);胰腺锐利度和整体图像质量在两种序列间几乎相当(P=.17-.96)。
诊断标准与关键数值
- 两位放射科医师使用5分制对运动伪影、条纹伪影、胰腺锐利度和整体图像质量进行置信度评分,并评估胰腺期扫描时机的适当性;4D FreeBreathing所有20例检查均显示适当的胰腺期图像,eTHRIVE仅16例(57%;阅片者1 P<.001)和18例(64%;阅片者2 P=.003)显示适当胰腺期图像。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the feasibility of a free-breathing sequence (4D FreeBreathing) combined with Compressed SENSE in dynamic contrast-enhanced pancreatic MRI and compare it with a breath-holding sequence (eTHRIVE).
METHOD: Patients who underwent pancreatic MRI, either eTHRIVE or 4D FreeBreathing, from April 2022 to November 2023 were included in this retrospective study. Two radiologists, who were unaware of the scan sequence, independently and randomly reviewed the images at the precontrast, pancreatic, portal venous, and equilibrium phases and assigned confidence scores for motion and streaking artifacts, pancreatic sharpness, and overall image quality using a 5-point scale. Furthermore, the radiologists assessed the appropriateness of the scan timing of the pancreatic phase. Mann-Whitney U and Fisher's exact tests were conducted to compare the confidence scores and adequacy of the pancreatic phase scan timing between eTHRIVE and 4D FreeBreathing.
RESULTS: Overall, 48 patients (median age, 71 years; interquartile range, 64-77 years; 24 women) were included. Among them, 20 patients (42%) were scanned using 4D FreeBreathing. The 4D FreeBreathing showed moderate streaking artifact but improved motion artifact (P <.001-.17) at all phases. Pancreatic sharpness and overall image quality were almost comparable between two sequences (P = .17-.96). All 20 examinations in 4D FreeBreathing showed appropriate pancreatic phase images, but only 16 (57%; P <.001 for reviewer 1) and 18 (64%; P = .003 for reviewer 2) examinations showed it in eTHRIVE.
CONCLUSION: The use of 4D FreeBreathing combined with Compressed SENSE was feasible in pancreatic MRI and provided appropriate pancreatic phase images in all examinations.
引用
- Noda Y, Asano M, Kawai N, et al. Appropriate pancreatic phase image acquisition by free-breathing dynamic contrast-enhanced pancreatic MRI using stack-of-stars radial sampling and Compressed SENSE. Eur J Radiol. 2024. PMID: 38537605. doi:10.1016/j.ejrad.2024.111445
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。