疑似MASLD参与者肝脏脂肪变定量超声分析的操作者间可重复性:一项前瞻性研究
前瞻性纳入180例疑似代谢功能障碍相关脂肪性肝病(MASLD)成人,由两名经验不同的放射科医师分别行组织衰减成像(TAI)与组织散射分布成像(TSI),以质子磁共振波谱(1H-MRS)为参考标准。TAI与TSI操作者间可重复性良好(ICC分别为0.92和0.86),对≥5%肝脂肪变的诊断性能与临床预测模型相比更优。
要点
- TAI操作者间ICC为0.92,TSI为0.86,不同经验医师间可重复性良好。
- TAI与TSI检测≥5%肝脂肪变的AUC为0.90–0.96,两名医师间诊断性能无显著差异。
- TAI与TSI对≥5%肝脂肪变的诊断性能均优于临床预测模型。
核心结论
- TAI与TSI在不同经验放射科医师间具有良好可重复性,且对≥5%肝脂肪变诊断性能良好,优于临床预测模型。
研究设计与样本
- 前瞻性研究,纳入180例疑似MASLD成人(女56例、男124例,平均年龄46.98±14.92岁,平均BMI 25.81±4.47),于2022年8月至2022年9月招募;由两名经验不同的放射科医师行TAI和TSI,以1H-MRS为参考标准。
诊断标准与关键数值
- TAI-1、TAI-2、TSI-1和TSI-2检测≥5%肝脂肪变的AUC分别为0.90、0.96、0.91和0.96;TAI操作者间ICC=0.92,TSI操作者间ICC=0.86。
临床应用与阅片要点
- TAI与TSI操作者间可重复性良好,两名经验不同医师对≥5%肝脂肪变的诊断性能统计学相似且均优于临床预测模型,可考虑用于肝脏脂肪变定量评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the reproducibility of tissue attenuation imaging (TAI) and tissue scatter distribution imaging (TSI) measurements in adults with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) between radiologists with varying experience.
MATERIALS AND METHODS: Participants with suspected MASLD were prospectively recruited. TAI and TSI were performed for each participant by two radiologists with different levels of experience. Interoperability reliability was assessed on the basis of Bland-Altman analysis and intraclass correlation coefficients (ICCs). The study determined and compared the diagnostic performance of TAI and TSI with clinical prediction models using proton magnetic resonance spectroscopy (1H-MRS) as a reference.
RESULTS: A total of 180 participants (women, n = 56; men, n = 124, mean age, 46.98 ± 14.92 years; mean BMI, 25.81 ± 4.47) were enrolled from August 2022 to September 2022. Bland-Altman plots showed only slight deviation in the TAI and TSI results of the two radiologists; there was good interoperator reproducibility for TAI (ICC = 0.92) and TSI (ICC = 0.86). Senior and junior radiologists performed examinations labeled as TAI-1 and TSI-1, and TAI-2 and TSI-2, respectively. The areas under the curves (AUCs) of TAI-1, TAI-2, TSI-1, and TAI-2 for the detection of ≥5 % hepatic steatosis were 0.90, 0.96, 0.91 and 0.96, respectively. According to ROC analysis, the diagnostic performance of both radiologists for TAI and TSI was statistically similar and superior to that of the clinical prediction model.
CONCLUSIONS: TAI and TSI have good reproducibility between radiologists with different levels of experience. Meanwhile, both TAI and TSI demonstrated good diagnostic performance for hepatic steatosis (≥5%), surpassing that of clinical prediction models.
引用
- Yin H, Xiong B, Yu J, et al. Interoperator reproducibility of quantitative ultrasound analysis of hepatic steatosis in participants with suspected MASLD: A prospective study. Eur J Radiol. 2024. PMID: 38522397. doi:10.1016/j.ejrad.2024.111427
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。