文献速递腹部外周血管CT

正中弓状韧带综合征的放射解剖学研究:揭示正中弓状韧带、腹腔干与肠系膜上动脉的形态与形态计量学特征

A radio-anatomical study of median arcuate ligament syndrome: unveiling the morphology and morphometry of median arcuate ligament, celiac trunk, and superior mesenteric artery.
PubMed 文献 · Abdom Radiol (NY) · 2024-03-17

在250例CT血管造影及11具尸体解剖中测量正中弓状韧带起点椎体水平、厚度、腹腔干起点、直径及其与正中弓状韧带中心的距离。放射学测得正中弓状韧带平均厚度7.79±2.58 mm,腹腔干多起自T12,与正中弓状韧带中心平均距离1.32±2.04 mm,腹腔干与腹主动脉夹角以钝角为主。组织学显示正中弓状韧带组成异质,提示不同区域机械性能可变。

要点

  • CT血管造影测得正中弓状韧带平均厚度7.79±2.58 mm,高于文献所述>4 mm的增厚指标。
  • 腹腔干多起自T12,与正中弓状韧带中心平均距离1.32±2.04 mm。
  • 腹腔干与腹主动脉夹角以钝角为主,腹腔干平均直径5.53±1.33 mm。

核心结论

  • 本研究提供正中弓状韧带与腹腔干解剖关系的形态计量学数据,所测人群平均厚度高于文献所述>4 mm的增厚指标,组织学显示正中弓状韧带组成异质、提示不同区域机械性能与功能可变。

研究设计与样本

  • 在250例CT血管造影上观察形态计量参数,并解剖11具尸体检查相同参数及行正中弓状韧带组织组织形态学检查。

关键影像表现/征象

  • CT血管造影测得正中弓状韧带平均厚度7.79±2.58 mm。
  • 腹腔干通常起自T12。
  • 腹腔干与正中弓状韧带中心平均距离1.32±2.04 mm。
  • 腹腔干与腹主动脉夹角以钝角为主。
  • 腹腔干平均直径5.53±1.33 mm。

诊断标准与关键数值

  • 文献所述正中弓状韧带平均厚度>4 mm为增厚指标,本研究观察到的平均厚度远高于此。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: In the context of medical literature, a significant lacuna exists in understanding median arcuate ligament syndrome (MALS). While clinical aspects are well documented, literature lacks a robust exploration of the anatomical relationship between the celiac trunk and the median arcuate ligament (MAL).

METHODS: Morphometric parameters, including the vertebral level of MAL origin, MAL thickness, celiac trunk (CeT) origin level, diameter, and distances between CeT/Superior Mesenteric Artery (SMA) and the MAL center were observed on 250 CT angiograms. Cadavers (n = 11) were dissected to examine the same parameters and histo-morphological examination of MAL tissue was done.

RESULTS: Radiological findings established average MAL thickness of 7.79 ± 2.58 mm. The celiac trunk typically originated at T12. The average distance between the celiac trunk and the MAL center was 1.32 ± 2.04 mm. The angle of the celiac trunk to the abdominal aorta was primarily obtuse. The average celiac trunk diameter was 5.53 ± 1.33 mm. Histological examinations revealed a diverse MAL composition, indicating variable mechanical properties.

CONCLUSION: This study provides comprehensive morphometric data on the anatomical relationship between the MAL and the celiac trunk. In contrast to available literature which says the average MAL thickness of > 4 mm is an indicator of increased thickness, we observed much higher average thickness in the studied population. The findings contribute to a better understanding of normal anatomical variations which can serve as reference values for accurate radiological diagnosis of MALS. The histological examination revealed the heterogeneous nature of the MAL tissue composition, suggesting variable mechanical properties and functions in different regions.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ganapathy A, Mohakud S, Rout S, et al. A radio-anatomical study of median arcuate ligament syndrome: unveiling the morphology and morphometry of median arcuate ligament, celiac trunk, and superior mesenteric artery. Abdom Radiol (NY). 2024. PMID: 38494467. doi:10.1007/s00261-024-04231-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。