深度学习图像重建用于经导管主动脉瓣植入规划:图像质量、诊断性能、对比剂用量与辐射剂量评估
前瞻性纳入128例行TAVI规划CT的患者,随机分为DLIR-H组(n=64,80kVp、28mgI/kg/s对比剂注射率、DLIR-H重建)和常规组(n=64,100kVp、40mgI/kg/s、ASIR-V 50%重建)。DLIR-H组辐射剂量、对比剂用量和注射率均显著降低,SNR和CNR显著更高;以侵入性冠状动脉造影为标准,DLIR-H组对>50%狭窄的敏感度100%、特异度92.1%、NPV 100%、PPV 84.2%,常规组分别为94.7%、95.3%、97.6%、90.0%。
要点
- DLIR-H组辐射剂量4.94±0.39mSv,常规组7.93±1.20mSv,DLIR-H组显著降低(p<0.001)。
- DLIR-H组对比剂用量45.28±5.38mL,常规组63.26±9.88mL,DLIR-H组显著降低(p<0.001)。
- DLIR-H组图像SNR和CNR均显著高于常规组(均p<0.001)。
核心结论
- 在TAVI规划CT中,DLIR-H可改善图像质量,降低辐射剂量和对比剂用量,并对冠状动脉狭窄获得满意的诊断性能。
研究设计与样本
- 前瞻性随机对照研究,共纳入128例行TAVI规划CT的患者,随机分为DLIR-H组(n=64)和常规组(n=64);DLIR-H组采用80kVp管电压、体重依赖的对比剂注射率28mgI/kg/s、DLIR-H重建,常规组采用100kVp、对比剂注射率40mgI/kg/s、ASIR-V 50%重建;以侵入性冠状动脉造影为标准评估115例患者的冠状动脉狭窄诊断性能。
关键影像表现/征象
- DLIR-H组图像SNR和CNR均显著高于常规组(均p<0.001)。
诊断标准与关键数值
- DLIR-H组对>50%冠状动脉狭窄的患者水平诊断:敏感度100%、特异度92.1%、NPV 100%、PPV 84.2%。
- 常规组对>50%冠状动脉狭窄的患者水平诊断:敏感度94.7%、特异度95.3%、NPV 97.6%、PPV 90.0%。
临床应用与阅片要点
- DLIR-H组辐射剂量4.94±0.39mSv,常规组7.93±1.20mSv,DLIR-H组显著降低(p<0.001)。
- DLIR-H组对比剂用量45.28±5.38mL,常规组63.26±9.88mL,DLIR-H组显著降低(p<0.001)。
- DLIR-H组对比剂注射率3.1±0.31mL/s,常规组4.9±0.2mL/s,DLIR-H组显著降低(p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To assess image quality, contrast volume and radiation dose reduction potential and diagnostic performance with the use of high-strength deep learning image reconstruction (DLIR-H) in transcatheter aortic valve implantation (TAVI) planning CT.
METHODS: We prospectively enrolled 128 patients referred to TAVI-planning CT. Patients were randomly divided into two groups: DLIR-H group (n = 64) and conventional group (n = 64). The DLIR-H group was scanned with tube voltage of 80kVp and body weighted-dependent contrast injection rate of 28mgI/kg/s, images reconstructed using DLIR-H; the conventional group was scanned with 100kVp and contrast injection rate of 40mgI/kg/s, and images reconstructed using adaptive statistical iterative reconstruction-V at 50% (ASIR-V 50%). Radiation dose, contrast volume, contrast injection rate, and image quality were compared between the two groups. The diagnostic performance of TAVI planning CT for coronary stenosis in 115 patients were calculated using invasive coronary angiography as golden standard.
RESULTS: DLIR-H group significantly reduced radiation dose (4.94 ± 0.39mSv vs. 7.93 ± 1.20mSv, p < 0.001), contrast dose (45.28 ± 5.38 mL vs. 63.26 ± 9.88 mL, p < 0.001), and contrast injection rate (3.1 ± 0.31 mL/s vs. 4.9 ± 0.2 mL/s, p < 0.001) compared to the conventional group. Images in DLIR-H group had significantly higher SNR and CNR (all p < 0.001). For the diagnostic performance on a per-patient basis, TAVI planning CT in the DLIR-H group provided 100% sensitivity, 92.1% specificity, 100% negative predictive value (NPV), and 84.2% positive predictive value for the detection of > 50% stenosis. In the conventional group, the corresponding results were 94.7%, 95.3%, 97.6%, and 90.0%, respectively.
CONCLUSION: DLIR-H in TAVI-planning CT provides improved image quality with reduced radiation and contrast doses, and enables satisfactory diagnostic performance for coronary arteries stenosis.
引用
- Zhang Y, Liu Z, Cheng Y, et al. Deep Learning Image Reconstruction for Transcatheter Aortic Valve Implantation Planning: Image Quality, Diagnostic Performance, Contrast volume and Radiation Dose Assessment. Acad Radiol. 2024. PMID: 38472024. doi:10.1016/j.acra.2024.02.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。