文献速递心血管US

经食管超声心动图解剖标志自动检测与追踪用于左心室功能定量

Automatic Detection and Tracking of Anatomical Landmarks in Transesophageal Echocardiography for Quantification of Left Ventricular Function.
PubMed 文献 · Ultrasound Med Biol · 2024-03-13

研究基于245例经食管超声心动图记录,训练并测试多种先进网络用于二尖瓣环检测与追踪,构建自动估算二尖瓣环平面收缩期位移(MAPSE)的autoMAPSE流程。与专家手动参考值比较,Echolab患者平均差异0.8 mm(95%一致性界限-2.9至4.7),可行性85.7%;重症监护患者平均差异0.6 mm(95%一致性界限-2.3至3.5),可行性88.1%。临床原型实现实时性能,自动定量左心室功能可行性高,与手动参考的一致性可与临床专家观察者间变异相当。

要点

  • autoMAPSE自动估算MAPSE与专家手动参考一致性可与临床专家观察者间变异相当。
  • Echolab患者可行性85.7%,重症监护患者可行性88.1%。
  • 临床原型autoMAPSE实现实时性能。

核心结论

  • 自动定量左心室功能在临床环境中可行性高,与手动参考的一致性可与临床专家观察者间变异相当。

研究设计与样本

  • 研究纳入来自St. Olav's University Hospital的245例患者经食管超声心动图记录,用于训练和测试二尖瓣环检测与追踪网络。
  • 在30例Echolab患者和50例重症监护患者中评估autoMAPSE估算值与专家超声心动图医师手动标注参考值的一致性。
  • 提出用于临床整合的autoMAPSE原型,并在重症监护病房的重症监护患者中测试。

诊断标准与关键数值

  • Echolab患者中,autoMAPSE与手动参考平均差异0.8 mm(95%一致性界限-2.9至4.7),可行性85.7%。
  • 重症监护患者中,autoMAPSE与手动参考平均差异0.6 mm(95%一致性界限-2.3至3.5),可行性88.1%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE).

METHODS: We investigated several state-of-the-art networks for both the detection and tracking of the mitral annulus in TEE. We integrated the networks into a pipeline for automatic assessment of LV function through estimation of the mitral annular plane systolic excursion (MAPSE), called autoMAPSE. TEE recordings from a total of 245 patients were collected from St. Olav's University Hospital and used to train and test the respective networks. We evaluated the agreement between autoMAPSE estimates and manual references annotated by expert echocardiographers in 30 Echolab patients and 50 critical care patients. Furthermore, we proposed a prototype of autoMAPSE for clinical integration and tested it in critical care patients in the intensive care unit.

RESULTS: Compared with manual references, we achieved a mean difference of 0.8 (95% limits of agreement: -2.9 to 4.7) mm in Echolab patients, with a feasibility of 85.7%. In critical care patients, we reached a mean difference of 0.6 (95% limits of agreement: -2.3 to 3.5) mm and a feasibility of 88.1%. The clinical prototype of autoMAPSE achieved real-time performance.

CONCLUSION: Automatic quantification of LV function had high feasibility in clinical settings. The agreement with manual references was comparable to inter-observer variability of clinical experts.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。