文献速递妇产影像外周血管技术与安全US

B-flow/时空影像相关M型超声提供量化正常人类妊娠期螺旋动脉重塑的新方法

B-flow/spatiotemporal image correlation M-mode ultrasound provides novel method to quantify spiral artery remodeling during normal human pregnancy.
PubMed 文献 · Ultrasound Obstet Gynecol · 2024-01-01

前瞻性纵向观察研究纳入290例正常妊娠孕妇,用B-flow/STIC M型超声在第一、第二、第三孕期量化螺旋动脉可扩张度及体积血流,并在部分孕妇中检测血清PlGF/sFlt-1比值。结果显示三者均随孕期进展而升高,提示该技术可在体内数字化量化螺旋动脉重塑。

要点

  • B-flow/STIC M型超声可于早、中、晚孕期测量螺旋动脉可扩张度(收缩期与舒张期管径差)。
  • 正常妊娠螺旋动脉可扩张度中位数从早孕0.17 cm升至晚孕0.26 cm。
  • 螺旋动脉体积血流中位数从早孕2.49 mL/心动周期升至晚孕7.79 mL/心动周期。

核心结论

  • B-flow/STIC M型超声可在体内数字化量化正常妊娠进展过程中螺旋动脉随心动周期的结构和生理性扩张,反映其转化为顺应性血管的重塑过程。

研究设计与样本

  • 前瞻性纵向观察研究,纳入290例正常妊娠孕妇,于第一、第二、第三孕期行B-flow/STIC M型超声检查,并在部分孕妇中检测血清PlGF与sFlt-1水平。

诊断标准与关键数值

  • 螺旋动脉可扩张度定义为收缩期血管管腔直径减去舒张期直径;第一、第二、第三孕期中位数(IQR)分别为0.17(0.14-0.21)cm、0.23(0.18-0.28)cm、0.26(0.21-0.35)cm,各孕期比较P<0.0001。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: During human pregnancy, placental extravillous trophoblasts replace vascular smooth muscle and elastic tissue within the walls of the uterine spiral arteries, thereby remodeling them into distensible low-resistance vessels to promote placental perfusion. The present study determined whether B-flow/spatiotemporal image correlation (STIC) M-mode ultrasonography provides an in-vivo imaging method able to digitally quantify spiral artery luminal distensibility as a physiological index of spiral artery remodeling during the advancing stages of normal human pregnancy.

METHODS: A prospective, longitudinal, observational study was conducted to quantify spiral artery distensibility (i.e. vessel luminal diameter at systole minus diameter at diastole) by B-flow/STIC M-mode ultrasonography during the first, second and third trimesters in 290 women exhibiting a normal pregnancy. Maternal serum levels of placental growth factor (PlGF) and soluble fms-like tyrosine kinase-1 (sFlt-1), growth factors that modulate important events in spiral artery remodeling, were quantified in a subset of the women in the first, second and third trimesters of pregnancy.

RESULTS: Median (interquartile range (IQR)) spiral artery distensibility increased progressively between the first (0.17 (0.14-0.21) cm), second (0.23 (0.18-0.28) cm) and third (0.26 (0.21-0.35) cm) trimesters of pregnancy (P < 0.0001 for all). Median (IQR) spiral artery volume flow increased progressively between the first (2.49 (1.38-4.99) mL/cardiac cycle), second (3.86 (2.06-6.91) mL/cardiac cycle) and third (7.79 (3.83-14.98) mL/cardiac cycle) trimesters (P < 0.001 for all). In accordance with the elevation in spiral artery distensibility, the median (IQR) ratio of serum PlGF/sFlt-1 × 103 levels increased between the first (7.2 (4.5-10.0)), second (22.7 (18.6-42.2)) and third (56.2 (41.9-92.5)) trimesters (P < 0.001 for all).

CONCLUSIONS: The present study shows that B-flow/STIC M-mode ultrasonography provides an in-vivo imaging technology to quantify digitally the structural and physiological expansion of the walls of the spiral arteries during the cardiac cycle as a consequence of their transformation into compliant vessels during advancing stages of normal human pregnancy. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Turan OM, Liang Y, Kelley B, et al. B-flow/spatiotemporal image correlation M-mode ultrasound provides novel method to quantify spiral artery remodeling during normal human pregnancy. Ultrasound Obstet Gynecol. 2024. PMID: 38477161. doi:10.1002/uog.27636

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。