冠状动脉CT血管成像收缩期与舒张期人工智能斑块测量可重复性研究
本研究纳入39例连续患者(23例男性,年龄66.2±11.5岁)的冠状动脉CT血管成像,重建收缩期末与舒张期中晚期图像,使用人工智能斑块分析软件(Autoplaque)定量分析186个病变的斑块与狭窄。收缩期与舒张期图像间所有斑块体积测量一致性与相关性极佳(Lin一致性系数0.97–0.99,R 0.96–0.98),各指标差异均无统计学意义(P>0.05)。作者结论认为,经进一步验证后,标准化斑块测量可在收缩期或舒张期图像上进行。
要点
- 收缩期与舒张期图像间人工智能定量斑块体积测量一致性极佳(Lin系数0.97–0.99)。
- 各斑块体积及直径狭窄率在收缩期与舒张期间差异均无统计学意义(P>0.05)。
- 经进一步验证后,标准化斑块测量可在收缩期或舒张期图像上进行。
核心结论
- 收缩期与舒张期图像上人工智能定量斑块测量一致性极佳且无实质性差异;经进一步验证后,标准化斑块测量可在收缩期或舒张期心脏相位进行。
研究设计与样本
- 连续纳入39例(23例男性,年龄66.2±11.5岁)视觉上存在冠状动脉粥样硬化且图像质量良好的患者,行双源CT冠状动脉CT血管成像,从同一次扫描重建收缩期末与舒张期中晚期图像,使用人工智能斑块分析软件(Autoplaque)定量分析斑块与狭窄,共分析186个病变。
诊断标准与关键数值
- 收缩期与舒张期图像间所有斑块体积测量一致性极佳:Lin一致性系数0.97–0.99,R 0.96–0.98;每患者总斑块体积收缩期1017.1±712.9 mm³ vs 舒张期1014.7±696.2 mm³、非钙化斑块体积861.5±553.7 mm³ vs 856.5±528.7 mm³、钙化斑块体积155.7±229.3 mm³ vs 158.2±232.4 mm³、低密度非钙化斑块体积151.4±106.1 mm³ vs 151.5±101.5 mm³、直径狭窄率42.5±18.4% vs 41.3±15.1%,各项差异均无统计学意义(P>0.05)。
临床应用与阅片要点
- 作者结论认为,经进一步验证后,标准化斑块测量可在收缩期或舒张期心脏相位进行;人工智能斑块分析软件可提供标准化斑块定量,与心脏相位无关。
局限性
- 作者结论写明需进一步验证(Following further validation)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Current coronary CT angiography (CTA) guidelines suggest both end-systolic and mid-diastolic phases of the cardiac cycle can be used for CTA image acquisition. However, whether differences in the phase of the cardiac cycle influence coronary plaque measurements is not known. We aim to explore the potential impact of cardiac phases on quantitative plaque assessment.
METHODS: We enrolled 39 consecutive patients (23 male, age 66.2 ± 11.5 years) who underwent CTA with dual-source CT with visually evident coronary atherosclerosis and with good image quality. End-systolic and mid- to late-diastolic phase images were reconstructed from the same CTA scan. Quantitative plaque and stenosis were analyzed in both systolic and diastolic images using artificial intelligence (AI)-enabled plaque analysis software (Autoplaque).
RESULTS: Overall, 186 lesions from 39 patients were analyzed. There were excellent agreement and correlation between systolic and diastolic images for all plaque volume measurements (Lin's concordance coefficient ranging from 0.97 to 0.99; R ranging from 0.96 to 0.98). There were no substantial intrascan differences per patient between systolic and diastolic phases (p > 0.05 for all) for total (1017.1 ± 712.9 mm3 vs. 1014.7 ± 696.2 mm3), non-calcified (861.5 ± 553.7 mm3 vs. 856.5 ± 528.7 mm3), calcified (155.7 ± 229.3 mm3 vs. 158.2 ± 232.4 mm3), and low-density non-calcified plaque volume (151.4 ± 106.1 mm3 vs. 151.5 ± 101.5 mm3) and diameter stenosis (42.5 ± 18.4% vs 41.3 ± 15.1%).
CONCLUSION: Excellent agreement and no substantial differences were observed in AI-enabled quantitative plaque measurements on CTA in systolic and diastolic images. Following further validation, standardized plaque measurements can be performed from CTA in systolic or diastolic cardiac phase.
CLINICAL RELEVANCE STATEMENT: Quantitative plaque assessment using artificial intelligence-enabled plaque analysis software can provide standardized plaque quantification, regardless of cardiac phase.
KEY POINTS: • The impact of different cardiac phases on coronary plaque measurements is unknown. • Plaque analysis using artificial intelligence-enabled software on systolic and diastolic CT angiography images shows excellent agreement. • Quantitative coronary artery plaque assessment can be performed regardless of cardiac phase.
引用
- Flores Tomasino G, Han D, Pimentel R, et al. Reproducibility of artificial intelligence-enabled plaque measurements between systolic and diastolic phases from coronary computed tomography angiography. Eur Radiol. 2024. PMID: 38466392. doi:10.1007/s00330-024-10688-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。