彩色多普勒成像在冠状动脉介入导丝导航中应用初探
本初步研究在体外水槽测试声学活性多普勒导丝(DGW),并在四头雄性家猪开胸模型中经右颈动脉置入Judkins左冠状动脉指引导管,利用彩色多普勒瞬时彩色标记导航DGW进入左前降支(LAD)。结果显示该彩色标记可瞬时界定DGW尖端并辅助指引导管与左主干开口对接,DGW可随灌注导管或OTW球囊导管进入LAD近段,提示超声导航声学活性DGW可行。
要点
- 声学活性多普勒导丝在彩色多普勒上产生瞬时彩色标记,可实时显示导丝尖端位置。
- 在四头开胸家猪中,该彩色标记辅助指引导管与左主干开口对接并导航导丝进入左前降支。
- 经灌注导管或OTW球囊导管注入靛胭脂蓝溶液后,彩色灌注区域确认导管位于左前降支近段。
核心结论
- 使用声学活性多普勒导丝的超声导航是可行的,本研究初步提出彩色多普勒导航冠状动脉内导丝定位的新概念。
研究设计与样本
- 初步研究:先在水槽中测试声学活性多普勒导丝,再在四头雄性家猪开胸模型中进行体内实验,经右颈动脉在B型超声引导下置入Judkins左冠状动脉指引导管。
关键影像表现/征象
- 波形发生器连接多普勒导丝后,换能器扫描可见导丝尖端压电晶体振动与换能器多普勒信号之间形成 distinct、瞬时的彩色标记。
- 该彩色标记可瞬时界定多普勒导丝尖端,并辅助指引导管与左主干开口对接。
- 带灌注导管或OTW球囊导管的多普勒导丝可进入左前降支,注入靛胭脂蓝溶液后彩色灌注区域确认导管位于左前降支近段。
临床应用与阅片要点
- 本初步研究提示彩色多普勒超声可用于PCI中声学活性多普勒导丝的尖端定位与导航,作者将其作为新概念提出。
- 导丝尖端位置以彩色多普勒上的瞬时彩色标记判定,导管位置以注入靛胭脂蓝溶液后的彩色灌注区域确认。
局限性
- 原文称本研究为初步研究(pilot study),样本为四头雄性家猪。
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To test the Doppler guide wire (DGW) for navigation of the wire positioning by color Doppler ultrasound in the setting of percutaneous coronary intervention (PCI).
METHODS: An acoustically active DGW was tested in a water tank before its in vivo use. A waveform generator was connected to the DGW, and a transducer scanned the DGW to visualize a Doppler shift signal between the vibrating piezoelectric crystal located at the DGW tip and Doppler signal from the transducer as a distinct, instantaneous color marker. An intracoronary injection was tested in four male domestic pigs using an open-chest setting. A Judkins left coronary guiding catheter was inserted into the ascending aorta via the right carotid artery under B-mode ultrasound guidance. The DGW with an infusion catheter or over-the-wire (OTW) balloon catheter was inserted into the guiding catheter. The color marker instantaneously defined the DGW tip and navigated the catheter into the left anterior descending artery (LAD).
RESULTS: The tip of the DGW was visualized within the guiding catheter by a distinct color marker and helped to engage the guiding catheter to the left main orifice. The DGW with an infusion or OTW balloon catheter was inserted into the LAD. We confirmed that the catheter was positioned in the proximal LAD by the colored territory perfused by an injected indigo carmine solution.
CONCLUSION: Ultrasound navigation using acoustically active DGW was feasible. Our pilot study introduces a new concept of color Doppler-navigated wire positioning in the coronary artery in the setting of PCI.
引用
- Katayama M, Yang EH, Belohlavek M, et al. A Pilot Study on Novel Use of Color Doppler Imaging for Navigation of Wiring in Coronary Interventions. Ultrasound Med Biol. 2024. PMID: 38433075. doi:10.1016/j.ultrasmedbio.2024.02.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。