文献速递妇产影像儿科影像心血管US

应用胎儿心脏量化技术评估感染孕妇COVID-19后胎儿心脏形态与收缩功能

Post-COVID-19 Fetal Cardiac Morphology and Systolic Evaluation in Infected Pregnant Women by Fetal Heart Quantification Technology.
PubMed 文献 · J Ultrasound Med · 2024-03-11

前瞻性纳入86例孕早期确诊COVID-19感染孕妇与90例健康孕妇,采用胎儿心脏量化技术(fetal HQ)比较左右心室整体球形指数、整体应变、面积变化分数及24节段缩短分数;结果显示COVID-19组左室整体应变与24节段缩短分数无统计学显著差异,但整体球形指数降低、左室面积变化分数与右室整体应变及面积变化分数减低,右室整体应变为不良妊娠结局的独立预测因子,最佳截断值-18.66%。

要点

  • COVID-19组胎儿右室整体应变为不良妊娠结局独立预测因子,最佳截断值-18.66%。
  • COVID-19组胎儿左室整体应变与24节段缩短分数较对照组无统计学显著差异。
  • COVID-19组胎儿整体球形指数、左室面积变化分数、右室整体应变及面积变化分数较对照组减低。

核心结论

  • 孕早期COVID-19感染可能对胎儿心脏形态和功能产生负面影响,胎儿心脏量化技术或可为早期识别感染孕妇胎儿心脏改变提供新的评估方法。

研究设计与样本

  • 前瞻性研究,纳入86例孕早期确诊COVID-19感染孕妇(COVID-19组)和90例健康孕妇(对照组),均行胎儿超声心动图检查,应用胎儿心脏量化技术比较两组胎儿左右心室整体球形指数、整体应变值、面积变化分数及24节段缩短分数。

关键影像表现/征象

  • COVID-19组胎儿左心室整体球形指数较对照组降低(1.24 vs 1.28)。
  • COVID-19组胎儿左心室面积变化分数较对照组减低(48.12% vs 50.50%)。
  • COVID-19组胎儿右心室整体应变较对照组减低(-23.55% vs -27.63%)。
  • COVID-19组胎儿右心室面积变化分数较对照组减低(41.74% vs 46.01%)。
  • 节段分析显示COVID-19组胎儿第20-24节段缩短分数较对照组减低。

诊断标准与关键数值

  • 右心室整体应变预测不良妊娠结局的最佳截断值为-18.66%。
  • COVID-19组与对照组左心室整体应变及24节段缩短分数差异无统计学显著差异。

临床应用与阅片要点

  • 胎儿心脏量化技术可用于评估孕早期COVID-19感染孕妇的胎儿心脏形态与收缩功能。
  • 右心室整体应变或有助于识别不良妊娠结局风险,最佳截断值为-18.66%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Due to the government's liberalization of epidemic control, the current 2019 novel coronavirus disease (COVID-19) has started to spread widely within China. This study aimed to use the fetal heart quantification (fetal HQ) technique to assess the cardiac function and morphology of the fetuses of pregnant women diagnosed with COVID-19 in the early stages of pregnancy.

METHODS: Exactly 86 pregnant women diagnosed with COVID-19 infection in early pregnancy (COVID-19 group) and 90 healthy pregnant women (control group) who underwent fetal echocardiography were prospectively included in this study. The fetal HQ technique was applied to compare the differences in the global sphericity index (GSI), global strain values (GS), fractional area change (FAC), and 24-segment fractional shortening (FS) of the left and right ventricles, between the COVID-19 group and the control group.

RESULTS: Compared with the control group, the differences in GS and 24-segment FS of the left ventricle in the COVID-19 group were not statistically significant. However, the COVID-19 group showed lower GSI values compared with the control group (1.24 vs 1.28). FAC (48.12%) of the left ventricle and GS (-23.55%), FAC (41.74%) of the right ventricle in the COVID-19 group were reduced compared with FAC (50.50%) of the left ventricle and GS (-27.63%), FAC (46.01%) of the right ventricle in the control group. Segmental analysis revealed reduced FS in segments 20-24 in the COVID-19 group compared with the control group. Right ventricular GS was an independent predictor of adverse pregnancy outcome with an optimal cutoff value of -18.66%.

CONCLUSIONS: The results suggest that COVID-19 infection in early pregnancy may have a negative impact on fetal cardiac morphology and function. Fetal HQ may offer a new assessment method for the early identification of fetal cardiac alterations in pregnant women infected with COVID-19.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhu F, Zhao Y, Wu J, et al. Post-COVID-19 Fetal Cardiac Morphology and Systolic Evaluation in Infected Pregnant Women by Fetal Heart Quantification Technology. J Ultrasound Med. 2024. PMID: 38465462. doi:10.1002/jum.16444

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。