经导管主动脉瓣置换术患者应用工作站CT血流储备分数评估冠状动脉疾病
这项回顾性单中心研究纳入112例拟行经导管主动脉瓣置换术的患者,比较工作站CT血流储备分数(CT-FFR)、有创血管造影和Agatston评分对冠状动脉疾病及24个月内主要不良心血管事件的预测价值。CT-FFR≤0.80预测MACE的HR为3.33(95%CI:1.56,7.10;P=.002),多变量校正后HR为2.89(95%CI:1.22,6.86;P=.02),而有创血管造影≥50%狭窄和Agatston评分≥1000均未达统计学显著。
要点
- CT-FFR≤0.80在70例狭窄≥50%患者中检出41例(59%)血流动力学相关CAD。
- CT-FFR≤0.80预测24个月内MACE的HR为3.33(95%CI:1.56,7.10;P=.002)。
- 中位随访24个月内112例中23例(20.5%)发生MACE,其中14例CT-FFR≤0.80。
核心结论
- 与传统CAD指标相比,CT-FFR能更好地预测TAVR术后不良结局。
- 筛查队列中相当一部分患者因影像条件不足而不适合基于CT的CAD评估。
研究设计与样本
- 回顾性单中心研究,2018年至2020年筛查434例拟行TAVR患者,最终纳入112例(平均年龄82.1岁±6.7;58例[52%]男性)。
- 获取有创血管造影、冠状动脉CT血管造影及Agatston评分,与工作站CT-FFR计算结果比较,评估CAD并预测24个月随访内MACE。
诊断标准与关键数值
- CT-FFR≤0.80提示血流动力学相关CAD,在70例狭窄≥50%患者中检出41例(59%)。
- CT-FFR≤0.80预测MACE的HR为3.33(95%CI:1.56,7.10;P=.002),多变量模型校正相关协变量后HR为2.89(95%CI:1.22,6.86;P=.02)。
- Agatston评分≥1000 Agatston单位预测MACE的HR为2.25(95%CI:0.98,5.21;P=.06),未达统计学显著。
- 有创血管造影诊断≥50%狭窄预测MACE的HR为0.94(95%CI:0.41,2.17;P=.88),未达统计学显著。
临床应用与阅片要点
- 工作站CT-FFR可用于TAVR术前规划中评估冠状动脉疾病并预测24个月内MACE。
- 筛查队列中35.0%(152/434)患者因影像条件不足不适合CT评估,阅片时需注意图像质量对CT-FFR可行性的影响。
局限性
- 本研究为回顾性单中心研究。
- 筛查队列中35.0%(152/434)患者因影像条件不足不适合评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To examine the clinical feasibility of workstation-based CT fractional flow reserve (CT-FFR) for coronary artery disease (CAD) evaluation during preprocedural planning in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods In this retrospective single-center study, 434 patients scheduled for TAVR between 2018 and 2020 were screened for study inclusion; a relevant proportion of patients (35.0% [152 of 434]) was not suitable for evaluation due to insufficient imaging properties. A total of 112 patients (mean age, 82.1 years ± 6.7 [SD]; 58 [52%] men) were included in the study. Invasive angiography findings, coronary CT angiography results, and Agatston score were acquired and compared with on-site CT-FFR computation for evaluation of CAD and prediction of major adverse cardiovascular events (MACE) within a 24-month follow-up. Results Hemodynamic relevant CAD, as suggested by CT-FFR of 0.80 or less, was found in 41 of 70 (59%) patients with stenosis of 50% or more. MACE occurred in 23 of 112 (20.5%) patients, from which 14 of 23 had stenoses with CT-FFR of 0.80 or less (hazard ratio [HR], 3.33; 95% CI: 1.56, 7.10; P = .002). CT-FFR remained a significant predictor of MACE after inclusion in a multivariable model with relevant covariables (HR, 2.89; 95% CI: 1.22, 6.86; P = .02). An Agatston score of 1000 Agatston units or more (HR, 2.25; 95% CI: 0.98, 5.21; P = .06) and stenoses of 50% or more determined via invasive angiography (HR, 0.94; 95% CI: 0.41, 2.17; P = .88) were not significant predictors of MACE. Conclusion Compared with conventional CAD markers, CT-FFR better predicted adverse outcomes after TAVR. A relevant portion of the screened cohort, however, was not suitable for CT-based CAD evaluation. Keywords: CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Coronary Arteries, Outcomes Analysis © RSNA, 2024 See also the commentary by Weir-McCall and Pugliese in this issue.
引用
- Steyer A, Puntmann VO, Nagel E, et al. Coronary Artery Disease Assessment via On-Site CT Fractional Flow Reserve in Patients Undergoing Transcatheter Aortic Valve Replacement. Radiol Cardiothorac Imaging. 2024. PMID: 38546330. doi:10.1148/ryct.230096
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。