文献速递心血管CT

低管电压冠状动脉CT血管成像对斑块及冠状动脉周围脂肪评估的影响:个体内比较

Effects of low-tube voltage coronary CT angiography on plaque and pericoronary fat assessment: intraindividual comparison.
PubMed 文献 · Eur Radiol · 2024-03-11

本研究对65例患者74个斑块的1002层图像进行个体内比较,分析低管电压(70/80/90 kV)与传统管电压(100/120 kV)对斑块成分体积及冠状动脉周围脂肪衰减指数的影响。低管电压组非钙化斑块CT值显著低于传统组(31.5±22.6 HU vs 54.6±21.3 HU,p<0.05),且坏死核心和钙化体积增加、纤维脂质体积及斑块周围和右冠状动脉FAI降低(p<0.001);70 kV亚组纤维和钙化体积变化幅度大于90 kV亚组(p<0.05)。

要点

  • 低管电压(尤其70 kV)显著影响斑块成分定量和冠状动脉周围FAI测量。
  • 低管电压下斑块成分呈极化模式:纤维脂质(中等密度)减少,坏死核心(低密度)和钙化(高密度)增加。
  • 相同或相近管电压条件下斑块及冠周脂肪评估具有可比性和可重复性。

核心结论

  • 低管电压尤其70 kV对冠状动脉斑块和FAI有显著影响。
  • 低电压对斑块成分的影响表现为极化模式,即纤维脂质(中等密度)减少,坏死核心(低密度)和钙化(高密度)增加。

研究设计与样本

  • 个体内比较研究,纳入因高螺距低管电压CCTA图像质量不佳而转诊行传统CCTA的患者。
  • 共纳入65例患者74个斑块的1002层图像,低电压组含70 kV(21例)、80 kV(31例)、90 kV(13例)亚组,传统组含100 kV(4例)和120 kV(61例)。
  • 测量总斑块及各成分体积和冠状动脉周围脂肪衰减指数(FAI)。

关键影像表现/征象

  • 低电压组非钙化斑块CT值为31.5±22.6 HU,传统组为54.6±21.3 HU(p<0.05)。
  • 与传统组相比,低电压组及其亚组的坏死核心和钙化体积增加,纤维脂质体积、斑块周围FAI和右冠状动脉FAI降低(p<0.001)。
  • 70 kV亚组纤维和钙化体积变化幅度较90 kV亚组增大(p<0.05)。

临床应用与阅片要点

  • 相同或相近管电压条件下斑块和冠状动脉周围脂肪评估具有可比性和可重复性。
  • 有必要针对各低管电压水平开展特异性阈值研究。
  • 有必要对各低管电压水平的特异性阈值或衰减差值进行校正。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the effects of low tube voltage on coronary plaques and pericoronary fat assessment, and to compare their extent among various levels of low voltage.

MATERIALS AND METHODS: Patients were recommended for high-pitch low-tube voltage coronary computed tomography angiography (CCTA), and they were included if they had poor image quality and were referred to a conventional CCTA. The patients were classified into a low-voltage group (with 70-kV, 80-kV, and 90-kV subgroups) and a conventional group (100/120 kV). Their total plaque and subcomponent volumes and pericoronary fat attenuation index (FAI) were measured.

RESULTS: A total of 1002 image slices (from 65 patients and 74 plaques) were included, including 21, 31, 13, 4, and 61 patients in the 70-kV, 80-kV, 90-kV, 100-kV, and 120-kV groups respectively. The CT values of noncalcified plaques in the conventional and low-voltage groups were 54.6 ± 21.3 HU and 31.5 ± 22.6 HU, respectively (p < 0.05). Compared with the conventional group, the necrotic core and calcification volume were increased, and the fibrolipid volume, periplaque, and right coronary artery FAI were decreased in the low-voltage group and its subgroups (p < 0.001). The magnitude of changes in fibrous and calcification volumes increased in the 70-kV subgroup compared with that in the 90-kV subgroup (p < 0.05).

CONCLUSION: Low tube voltages, particularly of 70 kV, have a significant effect on coronary plaque and FAI. The effect of low voltage on plaque composition is characterized by a polarization pattern, i.e., a decrease in fibrolipid (medium density) and an increase in necrotic core (low density) and calcification (high density).

CLINICAL RELEVANCE STATEMENT: Our results highlight the comparability and repeatability of plaque and pericoronary fat assessments facilitated by the same or a similar tube voltage. It is necessary to carry out studies on the specificity threshold of low tube voltage at each level.

KEY POINTS: • Low tube voltage had a significant effect on coronary plaque and pericoronary fat, particularly 70 kV. • The effect of low tube voltage on plaque composition shows the shift from medium-density mixed components to low- and high-density components. • It is necessary to correct the specificity threshold or attenuation difference for low tube voltage at each level.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pan Y, Gao Y, Wang Z, et al. Effects of low-tube voltage coronary CT angiography on plaque and pericoronary fat assessment: intraindividual comparison. Eur Radiol. 2024. PMID: 38466391. doi:10.1007/s00330-024-10648-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。