文献速递心血管胸部CTPET

人工智能定义的心脏解剖改善混合灌注成像的风险分层

AI-Defined Cardiac Anatomy Improves Risk Stratification of Hybrid Perfusion Imaging.
PubMed 文献 · JACC Cardiovasc Imaging · 2024-03-06

研究在3个中心连续纳入7613例无已知冠状动脉疾病的行SPECT/CT心肌灌注成像患者,用AI从CT衰减校正图像自动分割冠状动脉钙化和心脏结构。中位随访2.4年,1045例(13.7%)发生主要不良心血管事件。左心室质量和各心腔容积最高四分位组事件风险显著增高(HR 1.46–3.31),加入CT容积和左心室质量使连续净重分类指数改善23.1%。

要点

  • AI可从CT衰减校正图像自动测量左心室质量和心腔容积,处理耗时短。
  • 左心室质量及左心房、左心室、右心房、右心室容积最高四分位组MACE风险显著增高。
  • 联合CT容积与左心室质量使连续净重分类指数改善23.1%。

核心结论

  • AI可自动从CT衰减校正图像得出左心室质量和心腔容积,显著改善混合灌注成像的心血管风险评估。

研究设计与样本

  • 研究类型为多中心连续病例分析,共纳入3个中心7613例无已知冠状动脉疾病的行SPECT/CT心肌灌注成像患者,采用既往验证的AI模型从CT衰减校正图像分割冠状动脉钙化和心脏结构。

诊断标准与关键数值

  • 全自动AI处理冠状动脉钙化平均耗时6.2±0.2秒,心脏容积和左心室质量平均耗时15.8±3.2秒。
  • 左心室质量及左心房、左心室、右心房、右心室容积最高四分位组较最低四分位组MACE风险显著增高,HR范围1.46至3.31。
  • 加入所有CT容积和CT左心室质量后,连续净重分类指数改善23.1%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Computed tomography attenuation correction (CTAC) improves perfusion quantification of hybrid myocardial perfusion imaging by correcting for attenuation artifacts. Artificial intelligence (AI) can automatically measure coronary artery calcium (CAC) from CTAC to improve risk prediction but could potentially derive additional anatomic features.

OBJECTIVES: The authors evaluated AI-based derivation of cardiac anatomy from CTAC and assessed its added prognostic utility.

METHODS: The authors considered consecutive patients without known coronary artery disease who underwent single-photon emission computed tomography/computed tomography (CT) myocardial perfusion imaging at 3 separate centers. Previously validated AI models were used to segment CAC and cardiac structures (left atrium, left ventricle, right atrium, right ventricular volume, and left ventricular [LV] mass) from CTAC. They evaluated associations with major adverse cardiovascular events (MACEs), which included death, myocardial infarction, unstable angina, or revascularization.

RESULTS: In total, 7,613 patients were included with a median age of 64 years. During a median follow-up of 2.4 years (IQR: 1.3-3.4 years), MACEs occurred in 1,045 (13.7%) patients. Fully automated AI processing took an average of 6.2 ± 0.2 seconds for CAC and 15.8 ± 3.2 seconds for cardiac volumes and LV mass. Patients in the highest quartile of LV mass and left atrium, LV, right atrium, and right ventricular volume were at significantly increased risk of MACEs compared to patients in the lowest quartile, with HR ranging from 1.46 to 3.31. The addition of all CT-based volumes and CT-based LV mass improved the continuous net reclassification index by 23.1%.

CONCLUSIONS: AI can automatically derive LV mass and cardiac chamber volumes from CT attenuation imaging, significantly improving cardiovascular risk assessment for hybrid perfusion imaging.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Miller RJH, Shanbhag A, Killekar A, et al. AI-Defined Cardiac Anatomy Improves Risk Stratification of Hybrid Perfusion Imaging. JACC Cardiovasc Imaging. 2024. PMID: 38456877. doi:10.1016/j.jcmg.2024.01.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。