文献速递胸部CT

表现为磨玻璃结节的肺腺癌浸润性鉴别:双能CT参数与定量语义特征的联合应用

Differentiating the Invasiveness of Lung Adenocarcinoma Manifesting as Ground Glass Nodules: Combination of Dual-energy CT Parameters and Quantitative-semantic Features.
PubMed 文献 · Acad Radiol · 2024-03-19

研究纳入2022年6月至2023年9月间69例患者共74个手术切除的磨玻璃结节,评估双能CT虚拟单色图像CT值及定量语义特征鉴别原位腺癌-微浸润腺癌与浸润性腺癌的效能。多因素分析显示130 keV CT值、最大横断面长径、深或中度分叶征及结节内血管形态异常为独立预测因子,联合模型AUC达0.966,显著高于各单一危险因素(AUC 0.791-0.822)。

要点

  • 130 keV单色CT值、最大横断面长径、深或中度分叶征及结节内血管形态异常为浸润性腺癌独立预测因子。
  • 联合模型鉴别浸润性腺癌与原位-微浸润腺癌的AUC为0.966,敏感度95.2%、特异度94.3%、准确率94.8%。
  • 联合模型AUC显著高于各单一危险因素(AUC 0.791-0.822,均P<0.05)。

核心结论

  • 整合双能CT单色CT值与定量语义特征的多参数联合预测模型有潜力用于术前鉴别以磨玻璃结节为主的肺腺癌中浸润性腺癌与原位-微浸润腺癌。

研究设计与样本

  • 回顾性纳入2022年6月至2023年9月间69例患者共74个手术切除的磨玻璃结节,均行双能CT检查,以病理诊断为参考标准。

关键影像表现/征象

  • 浸润性腺癌组在40-130 keV各能级单色CT值均显著高于原位-微浸润腺癌组(均P<0.05)。
  • 深或中度分叶征是浸润性腺癌的独立预测因子(OR=19.88,P=0.005)。
  • 结节内血管形态异常是浸润性腺癌的独立预测因子(OR=25.57,P=0.017)。

诊断标准与关键数值

  • 联合预测模型鉴别浸润性腺癌与原位-微浸润腺癌:AUC 0.966,敏感度95.2%,特异度94.3%,准确率94.8%。
  • 单一危险因素鉴别浸润性腺癌与原位-微浸润腺癌:AUC 0.791-0.822,均低于联合模型(均P<0.05)。
  • 130 keV单色CT值每增加1个单位,浸润性腺癌的OR=1.02(P=0.013)。
  • 最大横断面长径每增加1个单位,浸润性腺癌的OR=1.40(P=0.014)。

临床应用与阅片要点

  • 阅片时可关注磨玻璃结节在双能CT 130 keV单色图像上的CT值,并结合最大横断面长径、深或中度分叶征及结节内血管形态异常综合评估浸润风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the diagnostic performance of dual-energy CT (DECT) parameters and quantitative-semantic features for differentiating the invasiveness of lung adenocarcinoma manifesting as ground glass nodules (GGNs).

MATERIALS AND METHODS: Between June 2022 and September 2023, 69 patients with 74 surgically resected GGNs who underwent DECT examinations were included. CT numbers on virtual monochromatic images were calculated at 40-130 keV generated from DECT. Quantitative morphological measurements and semantic features were evaluated on unenhanced CT images and compared between pathologically confirmed adenocarcinoma in situ (AIS)-minimally invasive adenocarcinoma (MIA) and invasive lung adenocarcinoma (IAC). Multivariable logistic regression analysis was used to identify independent predictors. The diagnostic performance was assessed by the area under the receiver operating characteristic curve (AUC) and compared using DeLong's test.

RESULTS: Monochromatic CT numbers at 40-130 keV were significantly higher in IAC than in AIS-MIA (all P < 0.05). Multivariate logistic analysis revealed that CT number of 130 keV (odds ratio [OR] = 1.02, P = 0.013), maximum cross-sectional long diameter (OR =1.40, P = 0.014), deep or moderate lobulation sign (OR =19.88, P = 0.005), and abnormal intranodular vessel morphology (OR = 25.57, P = 0.017) were independent predictors of IAC. The combined prediction model showed a favorable differentiation performance with an AUC of 0.966 (95.2% sensitivity, 94.3% specificity, 94.8% accuracy), which was significantly higher than that for each risk factor (AUC = 0.791-0.822, all P < 0.05).

CONCLUSION: A multi-parameter combined prediction model integrating monochromatic CT numbers from DECT and quantitative-semantic features is promising for the preoperative discrimination of IAC and AIS-MIA in GGN-predominant lung adenocarcinoma.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Chen M, Ding L, Deng S, et al. Differentiating the Invasiveness of Lung Adenocarcinoma Manifesting as Ground Glass Nodules: Combination of Dual-energy CT Parameters and Quantitative-semantic Features. Acad Radiol. 2024. PMID: 38508939. doi:10.1016/j.acra.2024.02.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。