文献速递骨肌介入CTDSA

椎体成形术联合椎弓根螺钉置入行椎体加固的可行性与技术要点

Combined vertebroplasty and pedicle screw insertion for vertebral consolidation: feasibility and technical considerations.
PubMed 文献 · Neuroradiology · 2024-03-08

回顾性评估4家介入放射中心2018至2023年57例患者,在CT联合透视引导下同期行椎体成形术与椎弓根螺钉置入,螺钉准确率95.7%,1个月随访VAS评分由7.7降至2.7(P < .001)。

要点

  • CT联合透视引导下同期行椎体成形与椎弓根螺钉置入,螺钉严格椎弓根内定位准确率为95.7%(89/93枚)。
  • 平均手术时间48.8分钟(SD=14.7),平均注入骨水泥量4.4 mL(SD=0.9)。
  • 术后1个月VAS评分由术前7.7(SD=1.3)降至2.7(SD=1.7),平均下降5分,P < .001。

核心结论

  • 在放射科环境下联合行椎体成形术与椎弓根螺钉置入技术可行,螺钉定位准确率达95.7%。

研究设计与样本

  • 回顾性研究,纳入2018至2023年4家介入放射中心57例(男38例、女19例,平均年龄72.8岁,SD=11.4)在CT联合透视引导下接受联合手术的患者,以严格椎弓根内螺钉定位为技术成功标准。

关键影像表现/征象

  • 共分析93枚椎弓根螺钉置入(36例双侧、21例单侧),分布于腰椎32个、胸椎22个、颈椎3个椎体水平。
  • 术后CT评估螺钉置入准确率为95.7%(89/93枚)。

诊断标准与关键数值

  • 技术成功定义为螺钉严格位于椎弓根内,术后CT评估准确率95.7%(89/93枚)。

临床应用与阅片要点

  • 术后CT可用于评估螺钉是否严格位于椎弓根内,本组准确率为95.7%(89/93枚)。
  • 术前与术后1个月采用视觉模拟量表评估疼痛,本组平均下降5分(7.7 vs 2.7),P < .001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the feasibility and technical accuracy of performing pedicular screw placement combined with vertebroplasty in the radiological setting.

METHODS: Patients who underwent combined vertebroplasty and pedicle screw insertion under combined computed tomography and fluoroscopic guidance in 4 interventional radiology centers from 2018 to 2023 were retrospectively assessed. Patient demographics, vertebral lesion type, and procedural data were analyzed. Strict intra-pedicular screw positioning was considered as technical success. Pain score was assessed according to the Visual Analogue Scale before the procedure and in the 1-month follow-up consultation.

RESULTS: Fifty-seven patients (38 men and 19 women) with a mean age of 72.8 (SD = 11.4) years underwent a vertebroplasty associated with pedicular screw insertion for the treatment of traumatic fractures (29 patients) and neoplastic disease (28 patients). Screw placement accuracy assessed by post-procedure CT scan was 95.7% (89/93 inserted screws). A total of 93 pedicle screw placements (36 bi-pedicular and 21 unipedicular) in 32 lumbar, 22 thoracic, and 3 cervical levels were analyzed. Mean reported procedure time was 48.8 (SD = 14.7) min and average injected cement volume was 4.4 (SD = 0.9) mL. A mean VAS score decrease of 5 points was observed at 1-month follow-up (7.7, SD = 1.3 versus 2.7, SD = 1.7), p < .001.

CONCLUSION: Combining a vertebroplasty and pedicle screw insertion is technically viable in the radiological setting, with a high screw positioning accuracy of 95.7%.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Kastler A, Carneiro I, Perolat R, et al. Combined vertebroplasty and pedicle screw insertion for vertebral consolidation: feasibility and technical considerations. Neuroradiology. 2024. PMID: 38453715. doi:10.1007/s00234-024-03325-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。