同日CT定量评估间质性肺疾病测量变异性:多中心前瞻性研究
这项多中心前瞻性研究纳入65例间质性肺疾病患者,于同日间隔数分钟行两次CT扫描,采用深度学习纹理分析软件分割纤维化特征。同日两次CT定量纤维化范围的绝对差异95%一致性界限为-0.9%至1.0%,相对差异为-14.8%至16.1%;不同重建参数扫描间变异性增大。定量CT信息提高了阅片者判断纤维化稳定性的特异度。
要点
- 同日两次CT定量纤维化范围的绝对差异95%一致性界限为-0.9%至1.0%。
- 不同重建参数扫描间绝对差异95%一致性界限扩大至-11.3%至3.9%。
- 定量CT信息使阅片者判断纤维化稳定性的特异度从91.7%升至94.6%。
核心结论
- 间质性肺疾病纤维化范围的定量CT绝对测量变异性在同日CT扫描中约为1%。
研究设计与样本
- 多中心前瞻性研究,2022年3月至10月纳入65例间质性肺疾病参与者,同日间隔数分钟行两次CT扫描,采用基于深度学习的纹理分析软件分割间质性肺疾病特征。
关键影像表现/征象
- 纤维化范围定义为网状影与蜂窝囊肿之和。
- 同日两次CT间定量纤维化范围的绝对差异95%一致性界限为-0.9%至1.0%,相对差异95%一致性界限为-14.8%至16.1%。
- 不同重建参数CT扫描间绝对差异95%一致性界限为-11.3%至3.9%,相对差异95%一致性界限为-123.1%至18.4%。
诊断标准与关键数值
- 同日两次CT绝对差异与基线纤维化范围无关联(P = .09)。
- 相对差异与基线纤维化范围呈负相关(β = -0.252,P < .001)。
- 8名阅片者判断30例随机样本间质性肺疾病纤维化稳定性,定量CT信息使特异度从91.7%提高至94.6%(P = .02)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To investigate quantitative CT (QCT) measurement variability in interstitial lung disease (ILD) on the basis of two same-day CT scans. Materials and Methods Participants with ILD were enrolled in this multicenter prospective study between March and October 2022. Participants underwent two same-day CT scans at an interval of a few minutes. Deep learning-based texture analysis software was used to segment ILD features. Fibrosis extent was defined as the sum of reticular opacity and honeycombing cysts. Measurement variability between scans was assessed with Bland-Altman analyses for absolute and relative differences with 95% limits of agreement (LOA). The contribution of fibrosis extent to variability was analyzed using a multivariable linear mixed-effects model while adjusting for lung volume. Eight readers assessed ILD fibrosis stability with and without QCT information for 30 randomly selected samples. Results Sixty-five participants were enrolled in this study (mean age, 68.7 years ± 10 [SD]; 47 [72%] men, 18 [28%] women). Between two same-day CT scans, the 95% LOA for the mean absolute and relative differences of quantitative fibrosis extent were -0.9% to 1.0% and -14.8% to 16.1%, respectively. However, these variabilities increased to 95% LOA of -11.3% to 3.9% and -123.1% to 18.4% between CT scans with different reconstruction parameters. Multivariable analysis showed that absolute differences were not associated with the baseline extent of fibrosis (P = .09), but the relative differences were negatively associated (β = -0.252, P < .001). The QCT results increased readers' specificity in interpreting ILD fibrosis stability (91.7% vs 94.6%, P = .02). Conclusion The absolute QCT measurement variability of fibrosis extent in ILD was 1% in same-day CT scans. Keywords: CT, CT-Quantitative, Thorax, Lung, Lung Diseases, Interstitial, Pulmonary Fibrosis, Diagnosis, Computer Assisted, Diagnostic Imaging Supplemental material is available for this article. © RSNA, 2024.
引用
- Lee JH, Chae KJ, Park J, et al. Measurement Variability of Same-Day CT Quantification of Interstitial Lung Disease: A Multicenter Prospective Study. Radiol Cardiothorac Imaging. 2024. PMID: 38483245. doi:10.1148/ryct.230287
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。